EKINOPS-MGNT2-MIB :: mgnt2AlmDef48b

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EKINOPS-MGNT2-MIB › mgnt2AlmDef48b

mgnt2AlmDef48b

Module: EKINOPS-MGNT2-MIB

OID (symbolic): EKINOPS-MGNT2-MIB::mgnt2AlmDef48b

OID (numeric): 1.3.6.1.4.1.20044.7.2.1.0.12

Node type: OBJECT-TYPE

Type: EkiOnOff

Access: read-only

Description: Power Input B Present :This OID indicates that there is not input power on the right power connector (B) This alarm indicates if the power input B is present (right power connector) DEF_48B powerProblem (36) equipmentAlarm (5) (2)

What is mgnt2AlmDef48b?

Alarm indicating no input power is present on the right-hand power connector (power input B) of the chassis, telling an admin that feed B needs attention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.20044.7.2.1.0.12
snmpwalk -v2c -c public <target> EKINOPS-MGNT2-MIB::mgnt2AlmDef48b

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.20044.7.2.1.0.12.1
snmpget -v2c -c public <target> EKINOPS-MGNT2-MIB::mgnt2AlmDef48b.1

Start monitoring Ekinops 360 optical transport/DWDM chassis (manager/trap config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EKINOPS-MGNT2-MIB::mgnt2AlmDef48b OID value, configure state conditions and alerts, and monitor any Ekinops 360 optical transport/DWDM chassis (manager/trap config) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.20044ekinopsEKINOPS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.20044.7mgnt2EKINOPS-MGNT2-MIB
1.3.6.1.4.1.20044.7.2mgnt2HardwareEKINOPS-MGNT2-MIB
1.3.6.1.4.1.20044.7.2.1mgnt2alarmsEKINOPS-MGNT2-MIB
1.3.6.1.4.1.20044.7.2.1.0mgnt2AlmsynthAlm0EKINOPS-MGNT2-MIB
1.3.6.1.4.1.20044.7.2.1.0.12mgnt2AlmDef48bEKINOPS-MGNT2-MIB