All MIBs › ECX25EXT-MIB
Category: Protocol: X.25
Description: Extended X.25 MIB providing vendor-specific management objects for X.25 packet-switched network interfaces.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ECX25EXT-MIB?
ECX25EXT-MIB is a legacy Equinox Systems (enterprise OID 434) proprietary MIB (extending RFC 1381) reporting per-port X.25 Level 3 protocol-frame counters. Its runtime-counters table, keyed by port reference, records transmitted/received counts for Restart-Request, Clear-Request, Reset-Request, Interrupt-Request, RNR (Receiver Not Ready), REJ (Reject), Call-Confirm, RR (Receiver Ready), Interrupt-Confirm, Clear-Confirm, and Reset-Confirm packets. As a performance/protocol-status MIB it lets an administrator watch X.25 control-packet exchange volume per port to diagnose signaling issues on legacy Equinox X.25 equipment. It is deployed on legacy Equinox Systems X.25 access equipment. Engineers can download the ECX25EXT-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ECX25EXT-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Legacy Equinox Systems X.25 access equipment
Monitoring Examples
An administrator checks x25RestartReqTxs and x25ClearReqRxs to diagnose recurring X.25 circuit resets on legacy Equinox X.25 access equipment.
What Can Be Monitored
- per-port X.25 Level 3 control-packet counters
This MIB depends on
Related MIBs
Imported Objects
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| eicon | 1.3.6.1.4.1.434 | |||
| NTF x25Reset | 1.3.6.1.4.1.434.0.2 | If the PLE sends or receives a reset, the agent should send an x25Reset trap. | ||
| NTF x25Restart | 1.3.6.1.4.1.434.0.451 | This trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should send a linkUp trap. Sending this trap means the agent does not send a linkDown and linkUp trap. | ||
| management | 1.3.6.1.4.1.434.2 | |||
| mibv2 | 1.3.6.1.4.1.434.2.2 | |||
| x25ext | 1.3.6.1.4.1.434.2.2.4.5 | |||
| x25CountersTable | 1.3.6.1.4.1.434.2.2.4.5.1 | not-accessible | Runtime counters table, one row per port | |
| x25CountEntry | 1.3.6.1.4.1.434.2.2.4.5.1.1 | not-accessible | The set of counters for one port. | |
| INT x25CountPortRef | 1.3.6.1.4.1.434.2.2.4.5.1.1.1 | INTEGER | read-only | The Port reference on which the X25 is running. |
| CTR x25RestartReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.2 | Counter | read-only | Restart request frames transmitted |
| CTR x25RestartReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.3 | Counter | read-only | Restart request frames received |
| CTR x25ClearReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.4 | Counter | read-only | Clear request frames transmitted |
| CTR x25ClearReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.5 | Counter | read-only | Clear request frames received |
| CTR x25ResetReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.6 | Counter | read-only | Reset request frames transmitted |
| CTR x25ResetReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.7 | Counter | read-only | Reset request frames received |
| CTR x25InterrReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.8 | Counter | read-only | Interrupt request frames transmitted |
| CTR x25InterrReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.9 | Counter | read-only | Interrupt request frames received |
| CTR x25RNRsTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.10 | Counter | read-only | Receiver not ready frames transmitted |
| CTR x25RNRsRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.11 | Counter | read-only | Receiver not ready frames received |
| CTR x25REJsTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.12 | Counter | read-only | Reject frames transmitted |
| CTR x25REJsRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.13 | Counter | read-only | Reject frames received |
| CTR x25CallConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.14 | Counter | read-only | Call confirm transmitted. |
| CTR x25CallConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.15 | Counter | read-only | Call confirm received. |
| CTR x25RRTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.16 | Counter | read-only | Receiver ready transmitted |
| CTR x25RRRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.17 | Counter | read-only | Receiver ready received |
| CTR x25IntConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.18 | Counter | read-only | Interrupt confirm transmitted |
| CTR x25IntConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.19 | Counter | read-only | Interrupt confirm received |
| CTR x25ClrConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.20 | Counter | read-only | Clear confirmation transmitted. |
| CTR x25ClrConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.21 | Counter | read-only | Clear confirmation received. |
| CTR x25ResetConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.22 | Counter | read-only | Reset confirm transmitted. |
| CTR x25ResetConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.23 | Counter | read-only | Reset confirm received. |
| CTR x25RestartConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.24 | Counter | read-only | Restart confirm transmitted. |
| CTR x25RestartConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.25 | Counter | read-only | Restart confirm received. |
| CTR x25CallReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.26 | Counter | read-only | The number of requests transmitted for a connection. |
| CTR x25CallReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.27 | Counter | read-only | The number of requests received for a connection. |
| CTR x25RegisterReqTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.28 | Counter | read-only | The number of register packets sent. Register packets are used to exchange registration information. |
| CTR x25RegisterReqRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.29 | Counter | read-only | The number of register packets received. |
| CTR x25RegisterConfirmTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.30 | Counter | read-only | Register confirm transmitted. |
| CTR x25RegisterConfirmRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.31 | Counter | read-only | Register confirm received. |
| CTR x25DataSegmentsTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.32 | Counter | read-only | The number of 64 bytes data blocks sent. |
| CTR x25DataSegmentsRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.33 | Counter | read-only | The number of 64 bytes data blocks received. |
| CTR x25CaractersTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.34 | Counter | read-only | The number of characters sent. |
| CTR x25CaractersRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.35 | Counter | read-only | The number of characters received. |
| CTR x25DiagnosticPktsTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.36 | Counter | read-only | The number of error information packets sent. |
| CTR x25DiagnosticPktsRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.37 | Counter | read-only | The number of error information packets received. |
| CTR x25UnknownPktsTxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.38 | Counter | read-only | The number of packets that could not be recognized as following the X.25 structure sent. |
| CTR x25UnknownPktsRxs | 1.3.6.1.4.1.434.2.2.4.5.1.1.39 | Counter | read-only | The number of packets that could not be recognized as following the X.25 structure received. |
| x25VCCallParmTable | 1.3.6.1.4.1.434.2.2.4.5.2 | not-accessible | This table contains only the objects of the Internet x25CallParmTable which are available from the EiconCard. For the complete description of x25CallParmTable, please refer to RFC1382. | |
| x25VCCallParmEntry | 1.3.6.1.4.1.434.2.2.4.5.2.1 | not-accessible | Entries of x25VCCallParmTable. | |
| INT x25VCCallParmPortIndex | 1.3.6.1.4.1.434.2.2.4.5.2.1.1 | INTEGER | read-only | The Port reference on which the X25 is running. |
| INT x25VCCallParmVCIndex | 1.3.6.1.4.1.434.2.2.4.5.2.1.2 | INTEGER | read-only | The number of Virtual Circuits. |
| INT x25VCCallParmInPacketSize | 1.3.6.1.4.1.434.2.2.4.5.2.1.3 | INTEGER | read-write | The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128. |
| INT x25VCCallParmOutPacketSize | 1.3.6.1.4.1.434.2.2.4.5.2.1.4 | INTEGER | read-write | The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128. |
| INT x25VCCallParmInWindowSize | 1.3.6.1.4.1.434.2.2.4.5.2.1.5 | INTEGER | read-write | The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| INT x25VCCallParmOutWindowSize | 1.3.6.1.4.1.434.2.2.4.5.2.1.6 | INTEGER | read-write | The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| OCT x25VCCallParmUserData | 1.3.6.1.4.1.434.2.2.4.5.2.1.7 | OCTET STRING | read-write | The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent. |
| OCT x25VCCallParmCallingNetworkFacilities | 1.3.6.1.4.1.434.2.2.4.5.2.1.8 | OCTET STRING | read-write | The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
| OCT x25VCCallParmCalledNetworkFacilities | 1.3.6.1.4.1.434.2.2.4.5.2.1.9 | OCTET STRING | read-write | The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
| x25OperTable | 1.3.6.1.4.1.434.2.2.4.5.3 | not-accessible | The operation parameters in use by the X.25 PLE. | |
| x25OperEntry | 1.3.6.1.4.1.434.2.2.4.5.3.1 | not-accessible | Entries of x25OperTable. | |
| CTR x25OperIndex | 1.3.6.1.4.1.434.2.2.4.5.3.1.1 | Counter | read-only | The ifIndex value for the X.25 interface. |
| INT x25OperInterfaceMode | 1.3.6.1.4.1.434.2.2.4.5.3.1.2 | INTEGER | read-only | Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place. |
| INT x25OperMaxActiveCircuits | 1.3.6.1.4.1.434.2.2.4.5.3.1.3 | INTEGER | read-only | Maximum number of circuits this PLE can support. |
| INT x25OperPacketSequencing | 1.3.6.1.4.1.434.2.2.4.5.3.1.4 | INTEGER | read-only | The modulus of the packet sequence number space. |
| NUM x25OperRestartTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.5 | PositiveInteger | read-only | The T20 restart timer in milliseconds. |
| NUM x25OperCallTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.6 | PositiveInteger | read-only | The T21 Call timer in milliseconds. |
| NUM x25OperResetTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.7 | PositiveInteger | read-only | The T22 Reset timer in milliseconds. |
| NUM x25OperClearTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.8 | PositiveInteger | read-only | The T23 Clear timer in milliseconds. |
| NUM x25OperWindowTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.9 | PositiveInteger | read-only | The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use. |
| NUM x25OperDataRxmtTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.10 | PositiveInteger | read-only | The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use. |
| NUM x25OperInterruptTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.11 | PositiveInteger | read-only | The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used. |
| NUM x25OperRejectTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.12 | PositiveInteger | read-only | The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use. |
| NUM x25OperRegistrationRequestTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.13 | PositiveInteger | read-only | The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use. |
| NUM x25OperMinimumRecallTimer | 1.3.6.1.4.1.434.2.2.4.5.3.1.14 | PositiveInteger | read-only | Minimum time interval between unsuccessful call attempts in milliseconds. |
| INT x25OperRestartCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.15 | INTEGER | read-only | The R20 restart retransmission count. |
| INT x25OperResetCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.16 | INTEGER | read-only | The r22 Reset retransmission count. |
| INT x25OperClearCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.17 | INTEGER | read-only | The r23 Clear retransmission count. |
| INT x25OperDataRxmtCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.18 | INTEGER | read-only | The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use. |
| INT x25OperRejectCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.19 | INTEGER | read-only | The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use. |
| INT x25OperRegistrationRequestCount | 1.3.6.1.4.1.434.2.2.4.5.3.1.20 | INTEGER | read-only | The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use. |
| INT x25OperNumberPVCs | 1.3.6.1.4.1.434.2.2.4.5.3.1.21 | INTEGER | read-only | The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number. |
| OID x25OperDefCallParamId | 1.3.6.1.4.1.434.2.2.4.5.3.1.22 | OBJECT IDENTIFIER | read-only | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE. |
| ADR x25OperLocalAddress | 1.3.6.1.4.1.434.2.2.4.5.3.1.23 | X121Address | read-only | The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs. |
| OID x25OperDataLinkId | 1.3.6.1.4.1.434.2.2.4.5.3.1.24 | OBJECT IDENTIFIER | read-only | This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE. |
| OID x25OperProtocolVersionSupported | 1.3.6.1.4.1.434.2.2.4.5.3.1.25 | OBJECT IDENTIFIER | read-only | Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree. |
| x25StatTable | 1.3.6.1.4.1.434.2.2.4.5.4 | not-accessible | Statistics information about this X.25 PLE. | |
| x25StatEntry | 1.3.6.1.4.1.434.2.2.4.5.4.1 | not-accessible | Entries of the x25StatTable. | |
| IFI x25StatIndex | 1.3.6.1.4.1.434.2.2.4.5.4.1.1 | IfIndexType | read-only | The ifIndex value for the X.25 interface. |
| CTR x25StatInCalls | 1.3.6.1.4.1.434.2.2.4.5.4.1.2 | Counter | read-only | The number of incoming calls received. |
| CTR x25StatInCallRefusals | 1.3.6.1.4.1.434.2.2.4.5.4.1.3 | Counter | read-only | The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select. |
| CTR x25StatInProviderInitiatedClears | 1.3.6.1.4.1.434.2.2.4.5.4.1.4 | Counter | read-only | The number of clear requests with a cause code other than DTE initiated. |
| CTR x25StatInRemotelyInitiatedResets | 1.3.6.1.4.1.434.2.2.4.5.4.1.5 | Counter | read-only | The number of reset requests received with cause code DTE initiated. |
| CTR x25StatInProviderInitiatedResets | 1.3.6.1.4.1.434.2.2.4.5.4.1.6 | Counter | read-only | The number of reset requests received with cause code other than DTE initiated. |
| CTR x25StatInRestarts | 1.3.6.1.4.1.434.2.2.4.5.4.1.7 | Counter | read-only | The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE. |
| CTR x25StatInDataPackets | 1.3.6.1.4.1.434.2.2.4.5.4.1.8 | Counter | read-only | The number of data packets received. |
| CTR x25StatInAccusedOfProtocolErrors | 1.3.6.1.4.1.434.2.2.4.5.4.1.9 | Counter | read-only | The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets. |
| CTR x25StatInInterrupts | 1.3.6.1.4.1.434.2.2.4.5.4.1.10 | Counter | read-only | The number of interrupt packets received by the PLE or over the PVC/VC. |
| CTR x25StatOutCallAttempts | 1.3.6.1.4.1.434.2.2.4.5.4.1.11 | Counter | read-only | The number of calls attempted. |
| CTR x25StatOutCallFailures | 1.3.6.1.4.1.434.2.2.4.5.4.1.12 | Counter | read-only | The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select. |
| CTR x25StatOutInterrupts | 1.3.6.1.4.1.434.2.2.4.5.4.1.13 | Counter | read-only | The number of interrupt packets send by the PLE or over the PVC/VC. |
| CTR x25StatOutDataPackets | 1.3.6.1.4.1.434.2.2.4.5.4.1.14 | Counter | read-only | The number of data packets sent by this PLE. |
| GAU x25StatOutgoingCircuits | 1.3.6.1.4.1.434.2.2.4.5.4.1.15 | Gauge | read-only | The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs. |
| GAU x25StatIncomingCircuits | 1.3.6.1.4.1.434.2.2.4.5.4.1.16 | Gauge | read-only | The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs. |
| GAU x25StatTwowayCircuits | 1.3.6.1.4.1.434.2.2.4.5.4.1.17 | Gauge | read-only | The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs. |
| CTR x25StatRestartTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.18 | Counter | read-only | The number of times the T20 restart timer expired. |
| CTR x25StatCallTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.19 | Counter | read-only | The number of times the T21 call timer expired. |
| CTR x25StatResetTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.20 | Counter | read-only | The number of times the T22 reset timer expired. |
| CTR x25StatClearTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.21 | Counter | read-only | The number of times the T23 clear timer expired. |
| CTR x25StatDataRxmtTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.22 | Counter | read-only | The number of times the T25 data timer expired. |
| CTR x25StatInterruptTimeouts | 1.3.6.1.4.1.434.2.2.4.5.4.1.23 | Counter | read-only | The number of times the T26 interrupt timer expired. |
| CTR x25StatRetryCountExceededs | 1.3.6.1.4.1.434.2.2.4.5.4.1.24 | Counter | read-only | The number of times a retry counter was exhausted. |
| CTR x25StatClearCountExceededs | 1.3.6.1.4.1.434.2.2.4.5.4.1.25 | Counter | read-only | The number of times the R23 clear count was exceeded. |
| x25ChannelTable | 1.3.6.1.4.1.434.2.2.4.5.5 | not-accessible | These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE. | |
| x25ChannelEntry | 1.3.6.1.4.1.434.2.2.4.5.5.1 | not-accessible | Entries of x25ChannelTable. | |
| IFI x25ChannelIndex | 1.3.6.1.4.1.434.2.2.4.5.5.1.1 | IfIndexType | read-only | The ifIndex value for the X.25 Interface. |
| INT x25ChannelLIC | 1.3.6.1.4.1.434.2.2.4.5.5.1.2 | INTEGER | read-write | Lowest Incoming channel. |
| INT x25ChannelHIC | 1.3.6.1.4.1.434.2.2.4.5.5.1.3 | INTEGER | read-write | Highest Incoming channel. A value of zero indicates no channels in this range. |
| INT x25ChannelLTC | 1.3.6.1.4.1.434.2.2.4.5.5.1.4 | INTEGER | read-write | Lowest Two-way channel. |
| INT x25ChannelHTC | 1.3.6.1.4.1.434.2.2.4.5.5.1.5 | INTEGER | read-write | Highest Two-way channel. A value of zero indicates no channels in this range. |
| INT x25ChannelLOC | 1.3.6.1.4.1.434.2.2.4.5.5.1.6 | INTEGER | read-write | Lowest outgoing channel. |
| INT x25ChannelHOC | 1.3.6.1.4.1.434.2.2.4.5.5.1.7 | INTEGER | read-write | Highest outgoing channel. A value of zero indicates no channels in this range. |
| x25CircuitTable | 1.3.6.1.4.1.434.2.2.4.5.6 | not-accessible | These objects contain general information about a specific circuit of an X.25 PLE. | |
| x25CircuitEntry | 1.3.6.1.4.1.434.2.2.4.5.6.1 | not-accessible | Entries of x25CircuitTable. | |
| IFI x25CircuitIndex | 1.3.6.1.4.1.434.2.2.4.5.6.1.1 | IfIndexType | read-only | The ifIndex value for the X.25 Interface. |
| INT x25CircuitChannel | 1.3.6.1.4.1.434.2.2.4.5.6.1.2 | INTEGER | read-only | The channel number for this circuit. |
| INT x25CircuitStatus | 1.3.6.1.4.1.434.2.2.4.5.6.1.3 | INTEGER | read-write | This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information. |
| TIK x25CircuitEstablishTime | 1.3.6.1.4.1.434.2.2.4.5.6.1.4 | TimeTicks | read-only | The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data. |
| INT x25CircuitDirection | 1.3.6.1.4.1.434.2.2.4.5.6.1.5 | INTEGER | read-write | The direction of the call that established this circuit. |
| CTR x25CircuitInOctets | 1.3.6.1.4.1.434.2.2.4.5.6.1.6 | Counter | read-only | The number of octets of user data delivered to upper layer. |
| CTR x25CircuitInPdus | 1.3.6.1.4.1.434.2.2.4.5.6.1.7 | Counter | read-only | The number of PDUs received for this circuit. |
| CTR x25CircuitInRemotelyInitiatedResets | 1.3.6.1.4.1.434.2.2.4.5.6.1.8 | Counter | read-only | The number of Resets received for this circuit with cause code of DTE initiated. |
| CTR x25CircuitInProviderInitiatedResets | 1.3.6.1.4.1.434.2.2.4.5.6.1.9 | Counter | read-only | The number of Resets received for this circuit with cause code other than DTE initiated. |
| CTR x25CircuitInInterrupts | 1.3.6.1.4.1.434.2.2.4.5.6.1.10 | Counter | read-only | The number of interrupt packets received for this circuit. |
| CTR x25CircuitOutOctets | 1.3.6.1.4.1.434.2.2.4.5.6.1.11 | Counter | read-only | The number of octets of user data sent for this circuit. |
| CTR x25CircuitOutPdus | 1.3.6.1.4.1.434.2.2.4.5.6.1.12 | Counter | read-only | The number of PDUs sent for this circuit. |
| CTR x25CircuitOutInterrupts | 1.3.6.1.4.1.434.2.2.4.5.6.1.13 | Counter | read-only | The number of interrupt packets sent on this circuit. |
| CTR x25CircuitDataRetransmissionTimeouts | 1.3.6.1.4.1.434.2.2.4.5.6.1.14 | Counter | read-only | The number of times the T25 data retransmission timer expired for this circuit. |
| CTR x25CircuitResetTimeouts | 1.3.6.1.4.1.434.2.2.4.5.6.1.15 | Counter | read-only | The number of times the T22 reset timer expired for this circuit. |
| CTR x25CircuitInterruptTimeouts | 1.3.6.1.4.1.434.2.2.4.5.6.1.16 | Counter | read-only | The number of times the T26 Interrupt timer expired for this circuit. |
| OID x25CircuitCallParamId | 1.3.6.1.4.1.434.2.2.4.5.6.1.17 | OBJECT IDENTIFIER | read-write | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters. |
| ADR x25CircuitCalledDteAddress | 1.3.6.1.4.1.434.2.2.4.5.6.1.18 | X121Address | read-write | For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs. |
| ADR x25CircuitCallingDteAddress | 1.3.6.1.4.1.434.2.2.4.5.6.1.19 | X121Address | read-write | For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs. |
| ADR x25CircuitOriginallyCalledAddress | 1.3.6.1.4.1.434.2.2.4.5.6.1.20 | X121Address | read-write | For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs. |
| STR x25CircuitDescr | 1.3.6.1.4.1.434.2.2.4.5.6.1.21 | DisplayString | read-write | A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information. |
| x25CallParmTable | 1.3.6.1.4.1.434.2.2.4.5.7 | not-accessible | These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table. | |
| x25CallParmEntry | 1.3.6.1.4.1.434.2.2.4.5.7.1 | not-accessible | Entries of x25CallParmTable. | |
| NUM x25CallParmIndex | 1.3.6.1.4.1.434.2.2.4.5.7.1.1 | PositiveInteger | read-only | A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations. |
| ENT x25CallParmStatus | 1.3.6.1.4.1.434.2.2.4.5.7.1.2 | EntryStatus | read-write | The status of this call parameter entry. See RFC 1271 for details of usage. |
| NUM x25CallParmRefCount | 1.3.6.1.4.1.434.2.2.4.5.7.1.3 | PositiveInteger | read-only | The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects are the x25AdmnDefCallParamId, x25OperDataLinkId, or x25AdmnDefCallParamId objects defined above. |
| INT x25CallParmInPacketSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.4 | INTEGER | read-write | The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128. |
| INT x25CallParmOutPacketSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.5 | INTEGER | read-write | The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128. |
| INT x25CallParmInWindowSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.6 | INTEGER | read-write | The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| INT x25CallParmOutWindowSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.7 | INTEGER | read-write | The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| INT x25CallParmAcceptReverseCharging | 1.3.6.1.4.1.434.2.2.4.5.7.1.8 | INTEGER | read-write | An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse. |
| INT x25CallParmProposeReverseCharging | 1.3.6.1.4.1.434.2.2.4.5.7.1.9 | INTEGER | read-write | An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local. |
| INT x25CallParmFastSelect | 1.3.6.1.4.1.434.2.2.4.5.7.1.10 | INTEGER | read-write | Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast select or restricted fast response. |
| INT x25CallParmInThruPutClasSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.11 | INTEGER | read-write | The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class. |
| INT x25CallParmOutThruPutClasSize | 1.3.6.1.4.1.434.2.2.4.5.7.1.12 | INTEGER | read-write | The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class. |
| STR x25CallParmCug | 1.3.6.1.4.1.434.2.2.4.5.7.1.13 | DisplayString | read-write | The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.) |
| STR x25CallParmCugoa | 1.3.6.1.4.1.434.2.2.4.5.7.1.14 | DisplayString | read-write | The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested. |
| STR x25CallParmBcug | 1.3.6.1.4.1.434.2.2.4.5.7.1.15 | DisplayString | read-write | The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested. |
| OCT x25CallParmNui | 1.3.6.1.4.1.434.2.2.4.5.7.1.16 | OCTET STRING | read-write | The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry. |
| INT x25CallParmChargingInfo | 1.3.6.1.4.1.434.2.2.4.5.7.1.17 | INTEGER | read-write | The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility. |
| STR x25CallParmRpoa | 1.3.6.1.4.1.434.2.2.4.5.7.1.18 | DisplayString | read-write | The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested. |
| INT x25CallParmTrnstDly | 1.3.6.1.4.1.434.2.2.4.5.7.1.19 | INTEGER | read-write | The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit. |
| STR x25CallParmCallingExt | 1.3.6.1.4.1.434.2.2.4.5.7.1.20 | DisplayString | read-write | The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested. |
| STR x25CallParmCalledExt | 1.3.6.1.4.1.434.2.2.4.5.7.1.21 | DisplayString | read-write | The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested. |
| INT x25CallParmInMinThuPutCls | 1.3.6.1.4.1.434.2.2.4.5.7.1.22 | INTEGER | read-write | The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested. |
| INT x25CallParmOutMinThuPutCls | 1.3.6.1.4.1.434.2.2.4.5.7.1.23 | INTEGER | read-write | The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested. |
| OCT x25CallParmEndTrnsDly | 1.3.6.1.4.1.434.2.2.4.5.7.1.24 | OCTET STRING | read-write | The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested. |
| OCT x25CallParmPriority | 1.3.6.1.4.1.434.2.2.4.5.7.1.25 | OCTET STRING | read-write | The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length. |
| STR x25CallParmProtection | 1.3.6.1.4.1.434.2.2.4.5.7.1.26 | DisplayString | read-write | A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested. |
| INT x25CallParmExptData | 1.3.6.1.4.1.434.2.2.4.5.7.1.27 | INTEGER | read-write | The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default. |
| OCT x25CallParmUserData | 1.3.6.1.4.1.434.2.2.4.5.7.1.28 | OCTET STRING | read-write | The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent. |
| OCT x25CallParmCallingNetworkFacilities | 1.3.6.1.4.1.434.2.2.4.5.7.1.29 | OCTET STRING | read-write | The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
| OCT x25CallParmCalledNetworkFacilities | 1.3.6.1.4.1.434.2.2.4.5.7.1.30 | OCTET STRING | read-write | The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities. |
RFC description
Eicon X.25 protocol extension management for wide-area networking.
Start monitoring Legacy Equinox Systems X.25 access equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.