DKSF-60-4-X-X-X :: npRelayState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDKSF-60-4-X-X-XnpRelayState

npRelayState

Module: DKSF-60-4-X-X-X

OID (symbolic): DKSF-60-4-X-X-X::npRelayState

OID (numeric): 1.3.6.1.4.1.25728.5500.5.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Actual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is on

What is npRelayState?

This read-only INTEGER reports the relay's actual current state, off(0) or on(1), regardless of whether that state came from manual control, a schedule, or the watchdog. An admin polls it to confirm whether power is actually flowing to the attached equipment before troubleshooting further.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25728.5500.5.1.15
snmpwalk -v2c -c public <target> DKSF-60-4-X-X-X::npRelayState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25728.5500.5.1.15.1
snmpget -v2c -c public <target> DKSF-60-4-X-X-X::npRelayState.1

Start monitoring NetPing DKSF-60 remote power/relay control unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DKSF-60-4-X-X-X::npRelayState OID value, configure state conditions and alerts, and monitor any NetPing DKSF-60 remote power/relay control unit from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25728lightcomDKSF-201-9-X-X-1
1.3.6.1.4.1.25728.5500npRelayDKSF-201-9-X-X-1
1.3.6.1.4.1.25728.5500.5npRelayTableDKSF-201-9-X-X-1
1.3.6.1.4.1.25728.5500.5.1npRelayEntryDKSF-201-9-X-X-1
Numeric OIDNameModule
1.3.6.1.4.1.25728.5500.5.1.15npRelayStateDKSF-60-4-X-X-X