| OID symbolic | OID numeric | Type | Access | Description |
| INT decBusActiveClients | 1.3.6.1.4.1.36.2.18.29.1.2.1.1 | INTEGER | read-only | The number of active clients of this BUS component.
This count only includes those clients which have
both Multicast Send and Multicast Forward VCCs. |
| INT decBusAdminStatus | 1.3.6.1.4.1.36.2.18.29.1.1.1.3 | INTEGER | read-write | The desired state of this BUS component.
When a BUS is distributed, this object controls the
'local' server component, as opposed to the overall
state of the BUS.
If a LES is connected to the BUS, enabling/disabling
either server may affect both of them. Otherwise it
is up to the network manager to coordinate the state
of the servers. |
| OCT decBusAtmAddress | 1.3.6.1.4.1.36.2.18.29.1.1.1.6 | OCTET STRING | read-only | The ATM address of this Broadcast and Unknown Server,
or Broadcast and Unknown Server component.
Clients establish Multicast Send VCCs to this address
as part of the BUS Connect phase of LAN Emulation. |
| decBusCallStatsEntry | 1.3.6.1.4.1.36.2.18.29.1.8.1 | | not-accessible | Each row contains connection statistics for one
Broadcast and Unknown Server. |
| decBusCallStatsGroup | 1.3.6.1.4.1.36.2.18.29.2.1.7 | | | |
| decBusCallStatsTable | 1.3.6.1.4.1.36.2.18.29.1.8 | | not-accessible | This table holds statistics on virtual circuit/leaf
establishment attempts.
It contains one row for each Broadcast and Unknown
Server, and acts as an extension to the
'decBusConfigTable'. |
| decBusCircuitGroup | 1.3.6.1.4.1.36.2.18.29.2.1.6 | | | |
| OCT decBusClientAtmAddress | 1.3.6.1.4.1.36.2.18.29.1.4.1.2 | OCTET STRING | read-only | The primary ATM address of the LAN Emulation Client. |
| decBusClientEntry | 1.3.6.1.4.1.36.2.18.29.1.4.1 | | not-accessible | Each entry describes an active LAN Emulation Client,
from the perspective of the BUS. |
| decBusClientGroup | 1.3.6.1.4.1.36.2.18.29.2.1.4 | | | |
| INT decBusClientID | 1.3.6.1.4.1.36.2.18.29.1.4.1.3 | INTEGER | read-only | Contains the first LECID the appropriate BUS has seen
for this client, or zero if none has been seen yet. |
| INT decBusClientIndex | 1.3.6.1.4.1.36.2.18.29.1.4.1.1 | INTEGER | read-only | A unique value for each table row. This value has no
predefined relation to a client's LECID. |
| INT decBusClientRowStatus | 1.3.6.1.4.1.36.2.18.29.1.4.1.6 | INTEGER | read-write | Provides a way to disconnect a LEC from the BUS.
When read, this object has the value 'active'. When
written, it only accepts the value 'destroy'.
Because the ability to disconnect clients could lead
to denial-of-service attacks, support for this
feature is strictly optional. |
| INT decBusClientState | 1.3.6.1.4.1.36.2.18.29.1.4.1.5 | INTEGER | read-only | Indicates the status of this LEC from the server's
perspective. |
| decBusClientStatesEntry | 1.3.6.1.4.1.36.2.18.29.1.2.1 | | not-accessible | Each row contains counters for one BUS component. |
| decBusClientStatesGroup | 1.3.6.1.4.1.36.2.18.29.2.1.2 | | | |
| decBusClientStatesTable | 1.3.6.1.4.1.36.2.18.29.1.2 | | not-accessible | A table describing how many clients are in various
membership states. |
| decBusClientTable | 1.3.6.1.4.1.36.2.18.29.1.4 | | not-accessible | A table listing clients of the emulated LANs which
this node serves.
This table reflects the actual membership of each
emulated LAN, as opposed to the desired membership. |
| INT decBusClientUsedSeveralIDs | 1.3.6.1.4.1.36.2.18.29.1.4.1.4 | INTEGER | read-only | Indicates whether the appropriate BUS has seen two or
more non-zero LEC IDs for this client. This is not a
normal condition, and it would usually arise due to a
transmission error in a frame or due to a client that
was violating the LAN Emulation specification. |
| decBusConfigEntry | 1.3.6.1.4.1.36.2.18.29.1.1.1 | | not-accessible | Each row of the table describes a standalone BUS or a
component of a BUS. |
| decBusConfigGroup | 1.3.6.1.4.1.36.2.18.29.2.1.1 | | | |
| decBusConfigTable | 1.3.6.1.4.1.36.2.18.29.1.1 | | not-accessible | A table which describes all the Broadcast and Unknown
Server components implemented by this managed device. |
| OCT decBusDescription | 1.3.6.1.4.1.36.2.18.29.1.1.1.7 | OCTET STRING | read-write | A human-readable string which can contain anything the
network manager wants. |
| OCT decBusEventClientAtmAddress | 1.3.6.1.4.1.36.2.18.29.1.10.1.6 | OCTET STRING | read-only | If known, the ATM address of the LAN Emulation Client
that was involved in this incident. |
| INT decBusEventIndex | 1.3.6.1.4.1.36.2.18.29.1.10.1.1 | INTEGER | read-only | A unique number greater than zero which identifies
this table row. |
| decBusEventLogEntry | 1.3.6.1.4.1.36.2.18.29.1.10.1 | | not-accessible | An entry describing a significant event. |
| decBusEventLogGroup | 1.3.6.1.4.1.36.2.18.29.2.1.8 | | | |
| INT decBusEventLogMaximumSize | 1.3.6.1.4.1.36.2.18.29.1.9 | INTEGER | read-write | The minimum number of events which the agent should
remember before purging old log entries to make way
for new ones. |
| decBusEventLogTable | 1.3.6.1.4.1.36.2.18.29.1.10 | | not-accessible | A table of event log entries for the emulated
LANs that this node serves. |
| INT decBusEventReason | 1.3.6.1.4.1.36.2.18.29.1.10.1.3 | INTEGER | read-only | The cause of the failure. |
| INT decBusEventServer | 1.3.6.1.4.1.36.2.18.29.1.10.1.4 | INTEGER | read-only | The 'decBusIndex' of the LAN Emulation Server that
was involved in this incident.
If the value of this object is zero, it indicates
that the server no longer exists. |
| OCT decBusEventServerAtmAddress | 1.3.6.1.4.1.36.2.18.29.1.10.1.5 | OCTET STRING | read-only | The ATM address of the Broadcast and Unknown Server
that was involved in this incident. |
| TIK decBusEventTimestamp | 1.3.6.1.4.1.36.2.18.29.1.10.1.7 | TimeTicks | read-only | The value of sysUpTime at the time that the event
occurred. If the event occurred prior to the last
re-initialization of the local network management
subsystem, this object contains a zero value. |
| INT decBusEventType | 1.3.6.1.4.1.36.2.18.29.1.10.1.2 | INTEGER | read-only | The event which triggered this log entry.
joinFailed(1) - A client tried to join one of the
broadcast domains which this host serves, but
the attempt failed. |
| CTR decBusFramesAgedOut | 1.3.6.1.4.1.36.2.18.29.1.3.1.3 | Counter | read-only | The number of frames which were discarded because
delay exceeded the Maximum Frame Age. |
| CTR decBusFramesDiscarded | 1.3.6.1.4.1.36.2.18.29.1.3.1.5 | Counter | read-only | The number of frames which could not be forwarded,
even though no errors had been detected, and the
frames had not aged out. |
| CTR decBusFramesForwarded | 1.3.6.1.4.1.36.2.18.29.1.3.1.1 | Counter | read-only | The number of frames successfully forwarded by this
Broadcast and Unknown Server. |
| CTR decBusFramesRateLimited | 1.3.6.1.4.1.36.2.18.29.1.3.1.4 | Counter | read-only | The number of frames which were discarded in order
to enforce 'decBusMaxForwardingRate'. |
| INT decBusIndex | 1.3.6.1.4.1.36.2.18.29.1.1.1.1 | INTEGER | read-only | A unique number greater than zero which identifies
this table row. |
| CTR decBusInvalidFrames | 1.3.6.1.4.1.36.2.18.29.1.3.1.2 | Counter | read-only | The number of frames which were discarded because
of errors (such as invalid frame length). |
| OCT decBusLanName | 1.3.6.1.4.1.36.2.18.29.1.1.1.8 | OCTET STRING | read-write | The name of this emulated LAN. While not required for
operational purposes, providing a LAN Name may make it
easier to keep track of which BUS component is which.
This string is not guaranteed to uniquely identify the
emulated LAN. |
| INT decBusLanType | 1.3.6.1.4.1.36.2.18.29.1.1.1.9 | INTEGER | read-write | The data frame format (or LAN-TYPE) for the emulated
LAN this Broadcast and Unknown Server supports.
In an active emulated LAN, this parameter MUST have a
consistent value in all of the LES and BUS components
serving the emulated LAN. Otherwise, problems may
result.
This columnar object's value may only be changed when
'decBus[Admin,Oper]Status' are 'down'. |
| TIK decBusLastChange | 1.3.6.1.4.1.36.2.18.29.1.1.1.5 | TimeTicks | read-only | The value of sysUpTime at the time that this server
last entered its current operational state. If the
current state was entered prior to the last
re-initialization of the local network management
subsystem, then this object contains a zero value. |
| OCT decBusLecAtmAddress | 1.3.6.1.4.1.36.2.18.29.1.5.1.1 | OCTET STRING | read-only | The primary ATM address of the LAN Emulation Client. |
| decBusLecEntry | 1.3.6.1.4.1.36.2.18.29.1.5.1 | | not-accessible | Each entry describes a LAN Emulation Client from the
perspective of the BUS. |
| decBusLecGroup | 1.3.6.1.4.1.36.2.18.29.2.1.5 | | | |
| INT decBusLecID | 1.3.6.1.4.1.36.2.18.29.1.5.1.3 | INTEGER | read-only | Contains the first LECID the appropriate BUS has seen
for this client, or zero if none has been seen yet. |
| INT decBusLecIndex | 1.3.6.1.4.1.36.2.18.29.1.5.1.2 | INTEGER | read-only | The client's index in the 'decBusClientTable'. Note
that this value is NOT the client's LEC-ID. |
| INT decBusLecRowStatus | 1.3.6.1.4.1.36.2.18.29.1.5.1.6 | INTEGER | read-write | Provides a way to disconnect a LEC from the BUS.
When read, this object has the value 'active'. When
written, it only accepts the value 'destroy'.
Because the ability to disconnect clients could lead
to denial-of-service attacks, support for this
feature is strictly optional. |
| INT decBusLecState | 1.3.6.1.4.1.36.2.18.29.1.5.1.5 | INTEGER | read-only | Indicates the status of this LEC from the server's
perspective. |
| decBusLecTable | 1.3.6.1.4.1.36.2.18.29.1.5 | | not-accessible | A table listing clients which belong to the emulated
LANs that this node serves. |
| INT decBusLecUsedSeveralIDs | 1.3.6.1.4.1.36.2.18.29.1.5.1.4 | INTEGER | read-only | Indicates whether the appropriate BUS has seen two or
more non-zero LEC IDs for this client. This is not a
normal condition, and it would usually arise due to a
transmission error in a frame or due to a client that
was violating the LAN Emulation specification. |
| INT decBusMaxDataFrameSize | 1.3.6.1.4.1.36.2.18.29.1.1.1.10 | INTEGER | read-write | The maximum AAL-5 SDU size for data frames sent over
this emulated LAN. This must be one of the standard
sizes defined in the LAN Emulation specification, in
other words either 1516, 4544, 9234, or 18190 octets.
In an active emulated LAN, this parameter MUST have a
consistent value in all of the LES and BUS components
serving the emulated LAN. Otherwise, problems may
result.
This columnar object's value may only be changed when
'decBus[Admin,Oper]Status' are 'down'. |
| INT decBusMaxForwardingRate | 1.3.6.1.4.1.36.2.18.29.1.1.1.12 | INTEGER | read-write | The maximum rate at which this Broadcast and Unknown
Server will forward frames. |
| INT decBusMaxFrameAge | 1.3.6.1.4.1.36.2.18.29.1.1.1.11 | INTEGER | read-write | The maximum amount of time which this Broadcast and
Unknown Server can hold a frame before being forced
to either forward or discard it.
If a BUS is distributed, each of its servers should
have the same value for this parameter. |
| CTR decBusMfClientRejects | 1.3.6.1.4.1.36.2.18.29.1.8.1.10 | Counter | read-only | The number of Multicast Forward connections which
this BUS component's clients refused to accept. |
| CTR decBusMfOutOfResourcesFailures | 1.3.6.1.4.1.36.2.18.29.1.8.1.9 | Counter | read-only | The number of Multicast Forward connections which
this BUS component could not establish due to lack
of resources. |
| decBusMIB | 1.3.6.1.4.1.36.2.18.29 | | | |
| decBusMIBCompliance | 1.3.6.1.4.1.36.2.18.29.2.2.1 | | | |
| decBusMIBCompliances | 1.3.6.1.4.1.36.2.18.29.2.2 | | | |
| decBusMIBConformance | 1.3.6.1.4.1.36.2.18.29.2 | | | |
| decBusMIBGroups | 1.3.6.1.4.1.36.2.18.29.2.1 | | | |
| decBusMIBObjects | 1.3.6.1.4.1.36.2.18.29.1 | | | |
| CTR decBusMsInvalidInfoElements | 1.3.6.1.4.1.36.2.18.29.1.8.1.4 | Counter | read-only | The number of Multicast Send establishment attempts
for this BUS component which failed because required
information elements were missing or contained
invalid information.
The optional Event Log group can help you determine
which information elements were invalid or missing.
This object does not count call failures included in
decBusMsWrongLanTypes or decBusMsWrongMaxFrameSizes. |
| CTR decBusMsOutOfResourcesFailures | 1.3.6.1.4.1.36.2.18.29.1.8.1.3 | Counter | read-only | The number of Multicast Send establishment attempts
for this BUS component which failed for lack of
resources. |
| CTR decBusMsWrongLanTypes | 1.3.6.1.4.1.36.2.18.29.1.8.1.5 | Counter | read-only | The number of Multicast Send establishment attempts
which were rejected because they specified a
different LAN Type (data frame format) than the
one configured for this BUS component. |
| CTR decBusMsWrongMaxFrameSizes | 1.3.6.1.4.1.36.2.18.29.1.8.1.6 | Counter | read-only | The number of Multicast Send establishment attempts
which were rejected because they specified a
different maximum AAL-5 SDU size than the one
configured for this BUS component. |
| CTR decBusMulticastForwardCalls | 1.3.6.1.4.1.36.2.18.29.1.8.1.7 | Counter | read-only | The number of Multicast Forward connections which
this BUS tried to establish. |
| CTR decBusMulticastForwardFailures | 1.3.6.1.4.1.36.2.18.29.1.8.1.8 | Counter | read-only | The number of Multicast Forward connections which
this BUS was unable to establish.
This includes failures counted in
decBusMfOutOfResourcesFailures
decBusMfClientRejects
and any miscellaneous failures. |
| decBusMulticastFwdEntry | 1.3.6.1.4.1.36.2.18.29.1.7.1 | | not-accessible | Each entry describes the circuits going to one LAN
Emulation Client. |
| INT decBusMulticastFwdInProgress | 1.3.6.1.4.1.36.2.18.29.1.2.1.2 | INTEGER | read-only | The number of clients to which this BUS component
is currently establishing Multicast Forward VCCs. |
| INT decBusMulticastFwdInterface | 1.3.6.1.4.1.36.2.18.29.1.7.1.1 | INTEGER | read-only | The 'ifIndex' of the ATM port which terminates the
Multicast Forward VCC at the BUS. |
| INT decBusMulticastFwdRowStatus | 1.3.6.1.4.1.36.2.18.29.1.7.1.4 | INTEGER | read-write | An object provided to satisfy the requirement that
all tables have at least one accessible object; in
the future, it may also be extended to provide PVC
support. |
| decBusMulticastFwdTable | 1.3.6.1.4.1.36.2.18.29.1.7 | | not-accessible | This optional table identifies Multicast Forward
VCCs at the place where they attach to the BUS.
In a SVC implementation, this table will be read-
only.
In a PVC implementation, this table can be used to
tell the BUS about the creation or the deletion of
Multicast Forward VCCs. |
| INT decBusMulticastFwdVci | 1.3.6.1.4.1.36.2.18.29.1.7.1.3 | INTEGER | read-only | The VCI of the Multicast Forward VCC at the point
where this VCC connects to the BUS. |
| INT decBusMulticastFwdVpi | 1.3.6.1.4.1.36.2.18.29.1.7.1.2 | INTEGER | read-only | The VPI of the Multicast Forward VCC at the point
where this VCC connects to the BUS. |
| CTR decBusMulticastSendCalls | 1.3.6.1.4.1.36.2.18.29.1.8.1.1 | Counter | read-only | The total number of Multicast Send establishment
attempts for this BUS component. |
| decBusMulticastSendEntry | 1.3.6.1.4.1.36.2.18.29.1.6.1 | | not-accessible | Each entry describes the circuits going to one LAN
Emulation Client. |
| CTR decBusMulticastSendFailures | 1.3.6.1.4.1.36.2.18.29.1.8.1.2 | Counter | read-only | The number of Multicast Send establishment attempts
for this BUS component which were not accepted.
This includes failures counted in
decBusMsOutOfResourcesFailures
decBusMsInvalidInfoElements
decBusMsWrongLanTypes
decBusMsWrongMaxFrameSizes
and any miscellaneous failures. |
| INT decBusMulticastSendInterface | 1.3.6.1.4.1.36.2.18.29.1.6.1.1 | INTEGER | read-write | If a Multicast Send PVC or SVC exists, this object
has a value equal to the 'ifIndex' of the ATM port
which terminates that circuit at the BUS.
Otherwise it has the value 0. |
| INT decBusMulticastSendRowStatus | 1.3.6.1.4.1.36.2.18.29.1.6.1.4 | INTEGER | read-write | Used to create and delete rows in the table. |
| decBusMulticastSendTable | 1.3.6.1.4.1.36.2.18.29.1.6 | | not-accessible | This optional table identifies Multicast Send VCCs
at the place where they attach to the BUS.
In a SVC implementation, the objects in this table
will be read-only.
In a PVC implementation, this table can be used to
tell the BUS about the creation or the deletion of
Multicast Send VCCs. |
| INT decBusMulticastSendVci | 1.3.6.1.4.1.36.2.18.29.1.6.1.3 | INTEGER | read-write | If a Multicast Send PVC or SVC exists, this object
has a value equal to the VCI of the Multicast Send
VCC at the point where it connects to the BUS.
Otherwise, it has the value 0. |
| INT decBusMulticastSendVpi | 1.3.6.1.4.1.36.2.18.29.1.6.1.2 | INTEGER | read-write | If a Multicast Send PVC or SVC exists, this object
has a value equal to the VPI of the Multicast Send
VCC at the point where it connects to the BUS.
Otherwise, it has the value 0. |
| INT decBusOperStatus | 1.3.6.1.4.1.36.2.18.29.1.1.1.4 | INTEGER | read-only | The operational state of this BUS component.
A BUS component may not become operational until it
has been configured with values for
LAN Type
Maximum Data Frame Size
Maximum Frame Age
When a BUS is in the 'disabling' or 'deleting' state,
attempts to set decBusAdminStatus to 'up' will fail. |
| INT decBusRowStatus | 1.3.6.1.4.1.36.2.18.29.1.1.1.2 | INTEGER | read-write | This object is used to create and delete Broadcast and
Unknown Server components.
If this object is writable, it will accept the values
'createAndGo'
'destroy'
under suitable conditions.
Use decBusAdminStatus to enable and disable service. |
| INT decBusTerminating | 1.3.6.1.4.1.36.2.18.29.1.2.1.3 | INTEGER | read-only | The number of clients whose memberships this BUS
component is in the process of terminating. |
| decBusTrafficEntry | 1.3.6.1.4.1.36.2.18.29.1.3.1 | | not-accessible | A set of traffic statistics for one BUS component. |
| decBusTrafficGroup | 1.3.6.1.4.1.36.2.18.29.2.1.3 | | | |
| decBusTrafficTable | 1.3.6.1.4.1.36.2.18.29.1.3 | | not-accessible | A table of traffic statistics, with one row for each
Broadcast and Unknown Server. |