DAMOCLES-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DAMOCLES-MIB

Category: Environmental Monitoring

Description: Monitors environmental sensors and dry contact inputs on HW group Damocles I/O monitoring units.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is DAMOCLES-MIB?

DAMOCLES-MIB is a private MIB (enterprise OID 21796) for a remote environmental/facility monitoring unit, reporting binary inputs, controllable outputs, and analog sensor readings. Its input table records state, name, alarm setup/state, and a transition counter per binary input, an output table records state, name, and type per controllable output, and a sensor table records state, name, a display string, scaled and raw values, an identifier, and a unit label per analog sensor. As a hardware-status MIB it lets a facilities team monitor a mix of digital alarm inputs (door, water, smoke) and analog readings (temperature, humidity) from one unit, and remotely actuate outputs. It is deployed on this vendor's remote environmental/facility monitoring unit. Engineers can download the DAMOCLES-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in DAMOCLES-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Remote environmental/facility monitoring unit

Monitoring Examples

A facilities team monitors sensValue alongside inpAlarmState to catch an environmental fault — combining a raw temperature reading with a discrete door-open alarm — from a single remote monitoring unit.

What Can Be Monitored

  • binary input alarm state
  • analog sensor readings
  • controllable output state
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Gauge
TimeTicks
enterprises

From RFC1213-MIB

DisplayString

From SNMPv2-SMI

Gauge32

How to Use in IPNetwork Monitor

Example using tsAlarmsPresent OID:

Select a Remote environmental/facility monitoring unit as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tsAlarmsPresent into the Find box to locate it in the OID tree, then select it and click OK. The present number of active alarm conditions. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Gauge32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Environmental monitoring MIB for sensors, binary inputs and outputs with alarm management.

Start monitoring Remote environmental/facility monitoring unit with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download DAMOCLES-MIB