CISCO-UNIFIED-COMPUTING-BIOS-MIB

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-BIOS-MIB

Organization: Cisco Systems Inc.

Last Updated: 2018-07-26

Description: MIB for BIOS settings, boot device order, and firmware policy configuration on Cisco Unified Computing System (UCS) rack and blade servers

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is CISCO-UNIFIED-COMPUTING-BIOS-MIB?

CISCO-UNIFIED-COMPUTING-BIOS-MIB is a Cisco Systems Inc. proprietary MIB modeling the BIOS management-information package for Cisco Unified Computing System (UCS). Its objects cover a BOT (Boot Order Table) table (instance ID, DN, last-update time), a boot-device table (instance ID, DN, description, order, device name, error value), and a boot-device-group table (instance ID, DN, description, order, type, device name, error value). As a configuration/status MIB it lets an administrator confirm BIOS boot-device order and catch boot-device errors within a Cisco UCS server profile. It is deployed on Cisco Systems Unified Computing System (UCS) server blades. Engineers can download the CISCO-UNIFIED-COMPUTING-BIOS-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-UNIFIED-COMPUTING-BIOS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Cisco Systems Unified Computing System (UCS) server blades

Monitoring Examples

An administrator checks cucsBiosBootDevOrder and cucsBiosBootDevErrValue to confirm BIOS boot-device order and catch boot errors on a Cisco UCS server blade.

What Can Be Monitored

  • BIOS boot-device order and error status
Imported Objects

From CISCO-SMI

ciscoMgmtOBJECT-IDENTITY

From CISCO-TC

CiscoAlarmSeverity
CiscoInetAddressMask
CiscoNetworkAddress
TimeIntervalSec
Unsigned64

From CISCO-UNIFIED-COMPUTING-MIB

CucsManagedObjectDn
CucsManagedObjectId
ciscoUnifiedComputingMIBObjectsOBJECT-IDENTITY

From CISCO-UNIFIED-COMPUTING-TC-MIB

CucsBiosBootDevErrorCode
CucsBiosBootDevGrpType
CucsBiosBootDevOrder
CucsBiosDefaultAction
CucsBiosSupportedAction
CucsBiosVfACPI10SupportVpACPI10Support
CucsBiosVfASPMSupportVpASPMSupport
CucsBiosVfAllUSBDevicesVpAllUSBDevices
CucsBiosVfAltitudeVpAltitude
CucsBiosVfAssertNMIOnPERRVpAssertNMIOnPERR
CucsBiosVfAssertNMIOnSERRVpAssertNMIOnSERR
CucsBiosVfBootOptionRetryVpBootOptionRetry
CucsBiosVfCPUHardwarePowerManagementVpCPUHardwarePowerManagement
CucsBiosVfCPUPerformanceVpCPUPerformance
CucsBiosVfConsistentDeviceNameControlVpCDNControl
CucsBiosVfConsoleRedirectionVpBaudRate
CucsBiosVfConsoleRedirectionVpConsoleRedirection
CucsBiosVfConsoleRedirectionVpFlowControl
CucsBiosVfConsoleRedirectionVpLegacyOSRedirection
CucsBiosVfConsoleRedirectionVpPuttyKeyPad
CucsBiosVfConsoleRedirectionVpTerminalType
CucsBiosVfCoreMultiProcessingVpCoreMultiProcessing
CucsBiosVfDDR3VoltageSelectionVpDDR3VoltageSelection
CucsBiosVfDRAMClockThrottlingVpDRAMClockThrottling
CucsBiosVfDirectCacheAccessVpDirectCacheAccess
CucsBiosVfDramRefreshRateVpDramRefreshRate
CucsBiosVfEnergyPerformanceTuningVpPwrPerfTuning
CucsBiosVfEnhancedIntelSpeedStepTechVpEnhancedIntelSpeedStepTech
CucsBiosVfEnhancedPowerCappingSupportVpEnhancedPowerCapping
CucsBiosVfExecuteDisableBitVpExecuteDisableBit
CucsBiosVfFRB2TimerVpFRB2Timer
CucsBiosVfFrequencyFloorOverrideVpFrequencyFloorOverride
CucsBiosVfFrontPanelLockoutVpFrontPanelLockout
CucsBiosVfIOEMezz1OptionROMVpIOEMezz1OptionROM
CucsBiosVfIOENVMe1OptionROMVpIOENVMe1OptionROM
CucsBiosVfIOENVMe2OptionROMVpIOENVMe2OptionROM
CucsBiosVfIOESlot1OptionROMVpIOESlot1OptionROM
CucsBiosVfIOESlot2OptionROMVpIOESlot2OptionROM
CucsBiosVfIntegratedGraphicsApertureSizeVpIntgtGraphApertureSize
CucsBiosVfIntegratedGraphicsVpIntegratedGraphics
CucsBiosVfIntelEntrySASRAIDModuleVpSASRAID
CucsBiosVfIntelEntrySASRAIDModuleVpSASRAIDModule
CucsBiosVfIntelHyperThreadingTechVpIntelHyperThreadingTech
CucsBiosVfIntelTrustedExecutionTechnologyVpIntelTstdExecTechSup
CucsBiosVfIntelTurboBoostTechVpIntelTurboBoostTech
CucsBiosVfIntelVTForDirectedIOVpIntelVTDATSSupport
CucsBiosVfIntelVTForDirectedIOVpIntelVTDCoherencySupport
CucsBiosVfIntelVTForDirectedIOVpIntelVTDInterruptRemapping
CucsBiosVfIntelVTForDirectedIOVpIntelVTDPassThroughDMASupport
CucsBiosVfIntelVTForDirectedIOVpIntelVTForDirectedIO
CucsBiosVfInterleaveConfigurationVpChannelInterleaving
CucsBiosVfInterleaveConfigurationVpMemoryInterleaving
CucsBiosVfInterleaveConfigurationVpRankInterleaving
CucsBiosVfLocalX2ApicVpLocalX2Apic
CucsBiosVfLvDIMMSupportVpLvDDRMode
CucsBiosVfMaxVariableMTRRSettingVpProcessorMtrr
CucsBiosVfMaximumMemoryBelow4GBVpMaximumMemoryBelow4GB
CucsBiosVfMemoryMappedIOAbove4GBVpMemoryMappedIOAbove4GB
CucsBiosVfMirroringModeVpMirroringMode
CucsBiosVfNUMAOptimizedVpNUMAOptimized
CucsBiosVfOSBootWatchdogTimerPolicyVpOSBootWatchdogTimerPolicy
CucsBiosVfOSBootWatchdogTimerTimeoutVpOSBootWatchdogTimerTimeout
CucsBiosVfOSBootWatchdogTimerVpOSBootWatchdogTimer
CucsBiosVfOnboardGraphicsVpOnboardGraphics
CucsBiosVfOnboardSATAControllerVpOnboardSATAController
CucsBiosVfOnboardSATAControllerVpSATAMode
CucsBiosVfOnboardStorageVpOnboardSCUStorageSupport
CucsBiosVfOptionROMEnableVpState
CucsBiosVfOptionROMLoadVpLoad
CucsBiosVfOutOfBandManagementVpComSpcrEnable
CucsBiosVfPCHSATAModeVpSATAMode
CucsBiosVfPCILOMPortsConfigurationVpPCIe10GLOM2Link
CucsBiosVfPCIROMCLPVpPCIROMCLP
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot10LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot1LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot2LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot3LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot4LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot5LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot6LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot7LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot8LinkSpeed
CucsBiosVfPCISlotLinkSpeedVpPCIeSlot9LinkSpeed
CucsBiosVfPCISlotOptionROMEnableVpPCIeSlotHBAOptionROM
CucsBiosVfPCISlotOptionROMEnableVpPCIeSlotMLOMOptionROM
CucsBiosVfPCISlotOptionROMEnableVpPCIeSlotN1OptionROM
CucsBiosVfPCISlotOptionROMEnableVpPCIeSlotN2OptionROM
CucsBiosVfPCISlotOptionROMEnableVpPCIeSlotSASOptionROM
CucsBiosVfPCISlotOptionROMEnableVpSlot10State
CucsBiosVfPCISlotOptionROMEnableVpSlot1State
CucsBiosVfPCISlotOptionROMEnableVpSlot2State
CucsBiosVfPCISlotOptionROMEnableVpSlot3State
CucsBiosVfPCISlotOptionROMEnableVpSlot4State
CucsBiosVfPCISlotOptionROMEnableVpSlot5State
CucsBiosVfPCISlotOptionROMEnableVpSlot6State
CucsBiosVfPCISlotOptionROMEnableVpSlot7State
CucsBiosVfPCISlotOptionROMEnableVpSlot8State
CucsBiosVfPCISlotOptionROMEnableVpSlot9State
CucsBiosVfPCISlotOptionROMEnableVpSlotMezzState
CucsBiosVfPOSTErrorPauseVpPOSTErrorPause
CucsBiosVfPSTATECoordinationVpPSTATECoordination
CucsBiosVfPackageCStateLimitVpPackageCStateLimit
CucsBiosVfProcessorC1EVpProcessorC1E
CucsBiosVfProcessorC3ReportVpProcessorC3Report
CucsBiosVfProcessorC6ReportVpProcessorC6Report
CucsBiosVfProcessorC7ReportVpProcessorC7Report
CucsBiosVfProcessorCMCIVpProcessorCMCI
CucsBiosVfProcessorCStateVpProcessorCState
CucsBiosVfProcessorEnergyConfigurationVpEnergyPerformance
CucsBiosVfProcessorEnergyConfigurationVpPowerTechnology
CucsBiosVfProcessorPrefetchConfigVpAdjacentCacheLinePrefetcher
CucsBiosVfProcessorPrefetchConfigVpDCUIPPrefetcher
CucsBiosVfProcessorPrefetchConfigVpDCUStreamerPrefetch
CucsBiosVfProcessorPrefetchConfigVpHardwarePrefetcher
CucsBiosVfQPILinkFrequencySelectVpQPILinkFrequencySelect
CucsBiosVfQPISnoopModeVpQPISnoopMode
CucsBiosVfQuietBootVpQuietBoot
CucsBiosVfRedirectionAfterBIOSPOSTVpRedirectionAfterPOST
CucsBiosVfResumeOnACPowerLossVpResumeOnACPowerLoss
CucsBiosVfSBMezz1OptionROMVpSBMezz1OptionROM
CucsBiosVfSBNVMe1OptionROMVpSBNVMe1OptionROM
CucsBiosVfSIOC1OptionROMVpSIOC1OptionROM
CucsBiosVfSIOC2OptionROMVpSIOC2OptionROM
CucsBiosVfScrubPoliciesVpDemandScrub
CucsBiosVfScrubPoliciesVpPatrolScrub
CucsBiosVfSerialPortAEnableVpSerialPortAEnable
CucsBiosVfSparingModeVpSparingMode
CucsBiosVfSriovConfigVpSriov
CucsBiosVfTPMPendingOperationVpTPMPendingOperation
CucsBiosVfTPMSupportVpTPMSupport
CucsBiosVfTrustedPlatformModuleVpTrustedPlatformModuleSupport
CucsBiosVfUCSMBootModeControlVpUEFIBootMode
CucsBiosVfUCSMBootOrderRuleControlVpUCSMBootOrderRule
CucsBiosVfUEFIOSUseLegacyVideoVpUEFIOSUseLegacyVideo
CucsBiosVfUSBBootConfigVpLegacyUSBSupport
CucsBiosVfUSBBootConfigVpMakeDeviceNonBootable
CucsBiosVfUSBConfigurationVpLegacyUSBSupport
CucsBiosVfUSBConfigurationVpXHCIMode
CucsBiosVfUSBFrontPanelAccessLockVpUSBFrontPanelLock
CucsBiosVfUSBPortConfigurationVpPort6064Emulation
CucsBiosVfUSBPortConfigurationVpUSBPortFront
CucsBiosVfUSBPortConfigurationVpUSBPortInternal
CucsBiosVfUSBPortConfigurationVpUSBPortKVM
CucsBiosVfUSBPortConfigurationVpUSBPortRear
CucsBiosVfUSBPortConfigurationVpUSBPortSDCard
CucsBiosVfUSBPortConfigurationVpUSBPortVMedia
CucsBiosVfUSBSysIdlePowerOptimizingSettingVpUSBIdlePowerOptimize
CucsBiosVfVGAPriorityVpVGAPriority
CucsBiosVfWorkloadConfigurationVpWorkloadConfiguration
CucsBiosVpIntelVirtualizationTechnology
CucsBiosVpSelectMemoryRASConfiguration
CucsPolicyPolicyOwner

From INET-ADDRESS-MIB

InetAddressIPv4
InetAddressIPv6

From SNMP-FRAMEWORK-MIB

SnmpAdminString

From SNMPv2-SMI

Counter32
Counter64
Gauge32
MODULE-IDENTITY
OBJECT-TYPE
TimeTicks
Unsigned32

From SNMPv2-TC

DateAndTime
DisplayString
MacAddress
RowPointer
TEXTUAL-CONVENTION
TimeInterval
TimeStamp
TruthValue
OIDs

RFC description

Manages BIOS configuration and settings for Cisco Unified Computing System servers and chassis.

Start monitoring Cisco UCS server blades with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CISCO-UNIFIED-COMPUTING-BIOS-MIB