CISCO-DLC-SWITCH-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-DLC-SWITCH-MIB

Organization: Cisco Systems, Inc.

Last Updated: 1997-02-19

Category: Cisco Devices, SNA and Legacy Protocols

Description: Manages Cisco DLC (Data Link Control) switching for LLC/DLC bridging, supporting legacy SNA and NetBIOS LAN-to-LAN connectivity.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is CISCO-DLC-SWITCH-MIB?

CISCO-DLC-SWITCH-MIB is a Cisco private MIB for managing FRAS (Frame Relay Access Server) BNN (Boundary Network Node) switching, which bridges legacy IBM SNA (SDLC) and NetBIOS (LLC) end-station sessions onto Frame Relay for delivery to an SNA host. It exposes per-session configuration and status data for downstream/end-station connections, namely SDLC session address, state, DLCI and Frame Relay interface for frasBnnSdlcConTable, and device MAC address and LAN SAPs for frasBnnLlcConTable. It is used to monitor the software status of individual legacy SNA/NetBIOS sessions, specifically each session's connection state (bnnSdlcConState), letting an administrator confirm that downstream terminals or controllers remain properly connected through the Frame Relay cloud to the mainframe. It explicitly complements the separate FRAS-HOST MIB, which covers the upstream/host-end side of these sessions, rather than duplicating it. It's typically deployed on Cisco routers acting as a Frame Relay Access Server/boundary network node in networks that still carry legacy SNA or NetBIOS traffic from branch terminals to a mainframe data center, where a CISCO-DLC-SWITCH-MIB download helps confirm each downstream session stays connected through the Frame Relay cloud.

IPNetwork Monitor allows you to monitor SNMP objects defined in CISCO-DLC-SWITCH-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Cisco router (Frame Relay Access Server / FRAS BNN)

Monitoring Examples

An administrator polls frasBnnSdlcConTable/frasBnnSdlcConEntry (keyed by bnnSdlcConAddress) to check bnnSdlcConState, bnnSdlcConDlci, and bnnSdlcConFRInterface for each SDLC-attached downstream device, confirming the session is up over the correct Frame Relay DLCI. For LAN-attached (LLC) sessions, frasBnnLlcConTable/bnnLlcConDeviceMacAddress and bnnLlcConLanLocalSap identify which end-station MAC address is bound to which local SAP. A session unexpectedly reporting a down or disconnected bnnSdlcConState would indicate a downstream SNA terminal or controller has lost its Frame Relay path to the host.

What Can Be Monitored

  • SDLC session connection state
  • SDLC session DLCI/Frame Relay interface
  • SDLC local/remote SAP
  • LLC session device MAC address
  • LLC session local SAP
Imported Objects

From CISCO-SMI

ciscoMgmtOBJECT-IDENTITY

From IF-MIB

InterfaceIndexOrZero

From RFC1213-MIB

ifIndex

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

MacAddress
TEXTUAL-CONVENTION

How to Use in IPNetwork Monitor

Example using bnnSdlcConState OID:

Select a Cisco router (Frame Relay Access Server / FRAS BNN, legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type bnnSdlcConState into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The FRAS connection state of this Link Station — reset, testSent, xidexchg, connrqsent, sigstnwait, connrspwait, connrspsent, contacted, or discwait. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'contacted' for longer than a normal connection setup takes, since 'contacted' is this link station's steady connected state. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Manages Frame Relay Access Support (FRAS) sessions for SDLC and LLC connections in bridged and routed formats.

Start monitoring Cisco router (Frame Relay Access Server / FRAS BNN, legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CISCO-DLC-SWITCH-MIB