CIENA-CES-PORT-MIB :: cienaCesPortNotificationPortDown

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PORT-MIBcienaCesPortNotificationPortDown

cienaCesPortNotificationPortDown

Module: CIENA-CES-PORT-MIB

OID (symbolic): CIENA-CES-PORT-MIB::cienaCesPortNotificationPortDown

OID (numeric): 1.3.6.1.4.1.1271.2.2.2.0.1

Node type: NOTIFICATION-TYPE

Description: A cienaCesLogicalPortNotificationPortDown trap signifies that the SNMP entity, acting in an agent role, has detected that the link status has become operationally down for one of its communication links. To enable the device to send this notification: - cienaCesPortEnhancedLinkTrapState needs to be set to enabled - cienaCesPortAllTrapState needs to be set to enabled - cienaCesLogicalPortConfigPortAllTrapState for the port needs to be set to enabled - cienaCesLogicalPortConfigPortLinkUpDownTrapState for the port needs to be set to enabled These objects are set to enabled by default. Variable bindings include: cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesPortPgIdMappingNotifChassisIndex, cienaCesPortPgIdMappingNotifShelfIndex, cienaCesPortPgIdMappingNotifSlotIndex, cienaCesPortPgIdMappingNotifPortNumber, cienaCesLogicalPortConfigPortAdminState, cienaCesLogicalPortConfigPortOperState, cienaCesLogicalPortConfigPortName, cienaCesLogicalPortConfigPortType, cienaCesLogicalPortConfigPortDesc, sysName, and sysLocation.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' CIENA-CES-PORT-MIB::cienaCesPortNotificationPortDown
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.1271.2.2.2.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:50595->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (462080419) 53 days, 11:33:24.19
  SNMPv2-MIB::snmpTrapOID.0 = OID: CIENA-CES-PORT-MIB::cienaCesPortNotificationPortDown

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PORT-MIB::cienaCesPortNotificationPortDown OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.2cienaCesNotificationsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.2.2cienaCesPortNotificationMIBNotificationPrefixCIENA-CES-PORT-MIB
1.3.6.1.4.1.1271.2.2.2.0cienaCesPortNotificationMIBNotificationsCIENA-CES-PORT-MIB
1.3.6.1.4.1.1271.2.2.2.0.1cienaCesPortNotificationPortDownCIENA-CES-PORT-MIB