All MIBs › CIENA-CES-MPLS-MIB › cienaCesMplsPwLocalFault
cienaCesMplsPwLocalFault
Module: CIENA-CES-MPLS-MIB
OID (symbolic): CIENA-CES-MPLS-MIB::cienaCesMplsPwLocalFault
OID (numeric): 1.3.6.1.4.1.1271.2.1.18.1.4.1.1.13
Node type: OBJECT-TYPE
Type: VCStatus
Access: read-only
Description: This represents the pseudowire local fault
What is cienaCesMplsPwLocalFault?
This reports the current fault status detected locally on this pseudowire's attachment circuit or forwarding path at this PE router, as opposed to a fault reported by the remote peer. This is the specific object an admin checks first when the local attachment circuit, such as the customer-facing Ethernet port, is suspected to be the source of a service disruption, isolating it from problems that might instead originate at the remote end. A local fault present here alongside a healthy remote fault status narrows the investigation specifically to this PE's local interface or hardware.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.18.1.4.1.1.13 snmpwalk -v2c -c public <target> CIENA-CES-MPLS-MIB::cienaCesMplsPwLocalFault
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.18.1.4.1.1.13.1 snmpget -v2c -c public <target> CIENA-CES-MPLS-MIB::cienaCesMplsPwLocalFault.1
Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-MPLS-MIB::cienaCesMplsPwLocalFault OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.18 | cienaCesMplsMIB | CIENA-CES-MPLS-MIB |
| 1.3.6.1.4.1.1271.2.1.18.1 | cienaCesMplsMIBObjects | CIENA-CES-MPLS-MIB |
| 1.3.6.1.4.1.1271.2.1.18.1.4 | cienaCesMplsPw | CIENA-CES-MPLS-MIB |
| 1.3.6.1.4.1.1271.2.1.18.1.4.1 | cienaCesMplsPwTable | CIENA-CES-MPLS-MIB |
| 1.3.6.1.4.1.1271.2.1.18.1.4.1.1 | cienaCesMplsPwEntry | CIENA-CES-MPLS-MIB |
| 1.3.6.1.4.1.1271.2.1.18.1.4.1.1.13 | cienaCesMplsPwLocalFault | CIENA-CES-MPLS-MIB |