CIENA-CES-MPLS-MIB :: cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-MPLS-MIBcienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute

cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute

Module: CIENA-CES-MPLS-MIB

OID (symbolic): CIENA-CES-MPLS-MIB::cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute

OID (numeric): 1.3.6.1.4.1.1271.2.1.18.1.2.4.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates whether or not an FRR (fast re-route) tunnel needs to be created for this dynamic encap tunnel.

What is cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute?

Per the object's own description this indicates whether an FRR backup tunnel needs to be created for this dynamic encap tunnel, applying here to a co-routed bidirectional circuit rather than a unidirectional one. An admin enabling this on a co-routed tunnel expects a local-repair backup covering both directions of the circuit to be pre-signaled, so a downstream failure triggers a fast switch for the whole bidirectional path rather than waiting on full end-to-end re-signaling. For example, this set to on(1) on a co-routed voice trunk should produce sub-100ms recovery in both directions if a link along the shared path fails, versus a multi-second gap without FRR.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.18.1.2.4.1.20
snmpwalk -v2c -c public <target> CIENA-CES-MPLS-MIB::cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.18.1.2.4.1.20.1
snmpget -v2c -c public <target> CIENA-CES-MPLS-MIB::cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute.1

Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-MPLS-MIB::cienaCesGmplsDynamicIngressCoroutedTunnelRecordRoute OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.18cienaCesMplsMIBCIENA-CES-MPLS-MIB
1.3.6.1.4.1.1271.2.1.18.1cienaCesMplsMIBObjectsCIENA-CES-MPLS-MIB
1.3.6.1.4.1.1271.2.1.18.1.2cienaCesGmplsCIENA-CES-MPLS-MIB
1.3.6.1.4.1.1271.2.1.18.1.2.4cienaCesGmplsDynamicIngressCoroutedTunnelTableCIENA-CES-MPLS-MIB
1.3.6.1.4.1.1271.2.1.18.1.2.4.1cienaCesGmplsDynamicIngressCoroutedTunnelEntryCIENA-CES-MPLS-MIB
1.3.6.1.4.1.1271.2.1.18.1.2.4.1.20cienaCesGmplsDynamicIngressCoroutedTunnelRecordRouteCIENA-CES-MPLS-MIB