Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CENTILLION-ATMCFG-MIB?
CENTILLION-ATMCFG-MIB is a Bay Networks (Centillion) proprietary MIB configuring ATM Emulated LAN (ELAN) instances on Centillion ATM switches. Its ELAN configuration table, keyed by ELAN index, records the ELAN type, enable state, total circuit count, and the virtual card/port/segment identifiers backing that ELAN. As a configuration MIB it lets an administrator confirm an ELAN is enabled and mapped to the correct virtual card/port before diagnosing a LAN Emulation connectivity problem. It is deployed on Bay Networks Centillion ATM switches providing LAN Emulation services. Engineers can download the CENTILLION-ATMCFG-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in CENTILLION-ATMCFG-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Bay Networks Centillion ATM switches
Monitoring Examples
An administrator checks atmElanEnable and atmElanVirtualPort for a specific ELAN index to confirm it's active and mapped to the expected virtual port before troubleshooting a LAN Emulation client connectivity issue.
What Can Be Monitored
- ELAN enable state, circuit count, and virtual card/port mapping
This MIB depends on
Related MIBs
Imported Objects
From CENTILLION-ROOT-MIB
| EnableIndicator | |
| atmConfig | OBJECT-IDENTITY |
From CENTILLION-VIRTUALSEGMENT-MIB
| VirtualSegmentTypeId |
From RFC-1212
| OBJECT-TYPE |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT atmCellCktEnable | 1.3.6.1.4.1.930.2.2.1.2.2.1.3 | INTEGER | read-write | Enable bit of the cell circuit. 1 = enable cell circuit 2 = disable cell circuit |
| OCT atmCellCktEndptList | 1.3.6.1.4.1.930.2.2.1.2.2.1.6 | OCTET STRING | read-write | List of endpoints for the circuit. Each endpoint includes Card (32 bit) Port (32 bit) Vpi (32 bit) Vci (32 bit) |
| atmCellCktEntry | 1.3.6.1.4.1.930.2.2.1.2.2.1 | not-accessible | ATM Cell Circuit table entry. Each entry is indexed by one field: The circuit index. | |
| INT atmCellCktIndex | 1.3.6.1.4.1.930.2.2.1.2.2.1.1 | INTEGER | read-write | The index to the packet circuit table. support total of 256 circuits. |
| INT atmCellCktNumEndpt | 1.3.6.1.4.1.930.2.2.1.2.2.1.5 | INTEGER | read-write | Number of endpoints in the circuit. An endpoint is defined as a combination of card/port/vpi/vci. |
| INT atmCellCktPriority | 1.3.6.1.4.1.930.2.2.1.2.2.1.2 | INTEGER | read-write | Priority bit of the circuit. 1 = normal priority 2 = high priority |
| INT atmCellCktStatus | 1.3.6.1.4.1.930.2.2.1.2.2.1.7 | INTEGER | read-write | The current status of the entry. Entries may be added by specifying a value of valid, and removed by setting the status to invalid. |
| atmCellCktTable | 1.3.6.1.4.1.930.2.2.1.2.2 | not-accessible | ATM virtual circuit table. | |
| INT atmCellCktType | 1.3.6.1.4.1.930.2.2.1.2.2.1.4 | INTEGER | read-write | type bit of the circuit. 1 = virtual circuit 2 = virtual path circuit |
| atmCktTable | 1.3.6.1.4.1.930.2.2.1.2 | |||
| INT atmCurPortLogConfig | 1.3.6.1.4.1.930.2.2.1.5.2 | INTEGER | read-only | The current number of logical links in the atmPortLogConfigTable. |
| OCT atmElanAllCkts | 1.3.6.1.4.1.930.2.2.1.1.1.1.4 | OCTET STRING | read-only | Return all pvc circuits that belong to this elan. Each circuit id is a 32 bit field |
| INT atmElanBridgeGroupId | 1.3.6.1.4.1.930.2.2.1.1.1.1.10 | INTEGER | read-only | Spanning Tree Group ID of the spanning tree group that the virtual segment and this Elan are members of. |
| atmElanConfig | 1.3.6.1.4.1.930.2.2.1.1 | |||
| atmElanConfigEntry | 1.3.6.1.4.1.930.2.2.1.1.1.1 | not-accessible | ATM elan table. Each entry is indexed by one field: elan id. | |
| atmElanConfigTable | 1.3.6.1.4.1.930.2.2.1.1.1 | not-accessible | ATM elan table | |
| INT atmElanEnable | 1.3.6.1.4.1.930.2.2.1.1.1.1.3 | INTEGER | read-write | Enable bit of the elan. 1 = enable elan 2 = disable elan |
| INT atmElanIndex | 1.3.6.1.4.1.930.2.2.1.1.1.1.1 | INTEGER | read-write | The index to the atm elan table. support total of 32 circuits. |
| INT atmElanMaxUnknownFrameCount | 1.3.6.1.4.1.930.2.2.1.1.1.1.11 | INTEGER | read-write | Maximum Unknown Frame Count. See the description of atmElanMaxUnknownFrameTime below. |
| INT atmElanMaxUnknownFrameTime | 1.3.6.1.4.1.930.2.2.1.1.1.1.12 | INTEGER | read-write | Maxinum Unknown Frame Time. Within the period of time defined by the Maxinum Unknown Frame Time, a LAN Client will send no more than Maxinum Unknown Frame Count frames for a given unicast LAN Destination. This time value is expressed in seconds. |
| INT atmElanStatus | 1.3.6.1.4.1.930.2.2.1.1.1.1.8 | INTEGER | read-write | The current status of the entry. Entries may be added by specifying a value of valid, and removed by setting the status to invalid. |
| INT atmElanType | 1.3.6.1.4.1.930.2.2.1.1.1.1.2 | INTEGER | read-write | The elan type. |
| ENA atmElanVcBridgingEnable | 1.3.6.1.4.1.930.2.2.1.1.1.1.13 | EnableIndicator | read-write | This object is used to enable or disable VC Bridging on the vport. The default value for this object is disable. |
| INT atmElanVirtualCard | 1.3.6.1.4.1.930.2.2.1.1.1.1.5 | INTEGER | read-only | Virtual card number. |
| INT atmElanVirtualPort | 1.3.6.1.4.1.930.2.2.1.1.1.1.6 | INTEGER | read-only | Virtual port number. Currently this number is the Elan id |
| INT atmElanVirtualSegmentId | 1.3.6.1.4.1.930.2.2.1.1.1.1.7 | INTEGER | read-only | Virtual Segment ID of the segment that this Elan is a member of |
| VIR atmElanVirtualSegmentType | 1.3.6.1.4.1.930.2.2.1.1.1.1.9 | VirtualSegmentTypeId | read-write | The virtual segment type. |
| INT atmMaxPortLogConfig | 1.3.6.1.4.1.930.2.2.1.5.1 | INTEGER | read-only | The maximum number of logical links in the atmPortLogConfigTable. |
| INT atmPktCktCardPort | 1.3.6.1.4.1.930.2.2.1.2.1.1.7 | INTEGER | read-write | The atm card/port of the circuit. The card/port takes one byte. This will be replaced by atmPktCktCardPort2 |
| INT atmPktCktCardPort2 | 1.3.6.1.4.1.930.2.2.1.2.1.1.11 | INTEGER | read-write | This mib is added for 24 ports card. This will replace atmPktCktCardPort. The atm card/port of the circuit. The card and port takes one byte each. |
| INT atmPktCktCost | 1.3.6.1.4.1.930.2.2.1.2.1.1.5 | INTEGER | read-write | The cost of the circuit. range from 0 to 255 with 0 the least cost. |
| INT atmPktCktElanIndex | 1.3.6.1.4.1.930.2.2.1.2.1.1.6 | INTEGER | read-write | The elan id this circuit belongs to. |
| INT atmPktCktEnable | 1.3.6.1.4.1.930.2.2.1.2.1.1.3 | INTEGER | read-write | Enable bit of the circuit. 1 = enable circuit 2 = disable circuit |
| atmPktCktEntry | 1.3.6.1.4.1.930.2.2.1.2.1.1 | not-accessible | ATM Packet Circuit table entry. Each entry is indexed by one field: The circuit index. | |
| INT atmPktCktIndex | 1.3.6.1.4.1.930.2.2.1.2.1.1.1 | INTEGER | read-write | The index to the packet circuit table. support total of 256 circuits. |
| INT atmPktCktPriority | 1.3.6.1.4.1.930.2.2.1.2.1.1.2 | INTEGER | read-write | Priority bit of the circuit. 1 = normal priority 2 = high priority |
| INT atmPktCktStatus | 1.3.6.1.4.1.930.2.2.1.2.1.1.10 | INTEGER | read-write | The current status of the entry. Entries may be added by specifying a value of valid, and removed by setting the status to invalid. |
| atmPktCktTable | 1.3.6.1.4.1.930.2.2.1.2.1 | not-accessible | ATM virtual circuit table. | |
| INT atmPktCktType | 1.3.6.1.4.1.930.2.2.1.2.1.1.4 | INTEGER | read-write | type bit of the circuit. 1 = virtual circuit 2 = virtual path circuit |
| INT atmPktCktVci | 1.3.6.1.4.1.930.2.2.1.2.1.1.9 | INTEGER | read-write | The packet circuit vci number. |
| INT atmPktCktVpi | 1.3.6.1.4.1.930.2.2.1.2.1.1.8 | INTEGER | read-write | The packet circuit vpi number. |
| INT atmPortAdminFrameMode | 1.3.6.1.4.1.930.2.2.1.3.1.1.16 | INTEGER | read-write | When read, this object returns the configured atm frame mode. When set, only modes sonet and sdh are supported. |
| INT atmPortCardIndex | 1.3.6.1.4.1.930.2.2.1.3.1.1.1 | INTEGER | read-write | This field indicates the ATM card id. |
| atmPortConfig | 1.3.6.1.4.1.930.2.2.1.3 | |||
| atmPortConfigEntry | 1.3.6.1.4.1.930.2.2.1.3.1.1 | not-accessible | ATM port configuration table. Each entry is indexed by two fields: The card index and the port index. | |
| atmPortConfigTable | 1.3.6.1.4.1.930.2.2.1.3.1 | not-accessible | ATM Hardware Port Configuration Table | |
| INT atmPortEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.3 | INTEGER | read-write | This field indicates if the ATM port is enabled or disabled. 2=Disable, 1=Enable. When the port is disabled, no cell traffic will be ggenerated nor accepted and not SONET signal is generated. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortForceHecErrorEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.10 | INTEGER | read-write | This field indicates if forcing cell header checksum error is enabled or disabled. 2=Disable, 1=Enable. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortHardwareFrameMode | 1.3.6.1.4.1.930.2.2.1.3.1.1.7 | INTEGER | read-only | This field indicates the atm frame mode detected by hardware, Sonet, SDH or NotApply (no cable plugged in) or other (value other than sonet and sdh). |
| INT atmPortHecCorrectionEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.6 | INTEGER | read-write | This field indicates if hec correction is enabled or disabled. 2=Disable, 1=Enable. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortHecCosetEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.5 | INTEGER | read-write | This field indicates if heccoset is enabled or disabled. 2=Disable, 1=Enable. When the port is disabled, no cell traffic will be ggenerated nor accepted and not SONET signal is generated. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortLocalLoopEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.8 | INTEGER | read-write | This field indicates if local loop is enabled or disabled. 2=Disable, 1=Enable. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| atmPortLogConfig | 1.3.6.1.4.1.930.2.2.1.5 | |||
| INT atmPortLogConfigAdmWeightCbr | 1.3.6.1.4.1.930.2.2.1.5.3.1.9 | INTEGER | read-write | The Administrative weight of this VP for the constant bit rate service category. A value of zero is returned if the link is non-PNNI. |
| INT atmPortLogConfigAdmWeightUbr | 1.3.6.1.4.1.930.2.2.1.5.3.1.10 | INTEGER | read-write | The Administrative weight of this VP for the unspecified bit rate service category. A value of zero is returned if the link is non-PNNI. |
| INT atmPortLogConfigCardIndex | 1.3.6.1.4.1.930.2.2.1.5.3.1.1 | INTEGER | read-only | This field indicates the ATM card id. |
| atmPortLogConfigEntry | 1.3.6.1.4.1.930.2.2.1.5.3.1 | not-accessible | ATM logical link configuration table. Each entry is indexed by three fields: The card index, port index and the VPI. | |
| INT atmPortLogConfigPortIndex | 1.3.6.1.4.1.930.2.2.1.5.3.1.2 | INTEGER | read-only | This field indicates ATM port id. |
| INT atmPortLogConfigSigEntityRole | 1.3.6.1.4.1.930.2.2.1.5.3.1.6 | INTEGER | read-write | This object indicates the role of the signaling entity that is associated with this ATM logical port. This object can only be set to user(2) or netw(3). A value of other(1) is returned when neither user(2) or netw(3) has been specified. |
| INT atmPortLogConfigSigEntityType | 1.3.6.1.4.1.930.2.2.1.5.3.1.5 | INTEGER | read-write | This object indicates the type of the signaling entity associated with this ATM port. The type of a signaling can either be no signaling, User-Network Interface, uni(2), Interim Interswitch Signaling Protocol, iisp(3) or Private Network-Network Interface, pnni(4). |
| INT atmPortLogConfigSigIlmi | 1.3.6.1.4.1.930.2.2.1.5.3.1.8 | INTEGER | read-write | This object is used to enable or disable ILMI. When atmPortLogConfigSigEntityType is set to uni(2) and atmPortLogConfigSigVersion is set to auto(2), this object must be set to enabled(1). When atmPortLogConfigSigEntityType is set to iisp(3), this object must be set to disabled(2). |
| INT atmPortLogConfigSigVersion | 1.3.6.1.4.1.930.2.2.1.5.3.1.7 | INTEGER | read-write | This object indicates the version of the signaling entity that is associated with this ATM port. When atmPortLogConfigSigEntityType is set to pnni(4), the signaling entity cannot be set to uni30(3) or uni31(4); It can be set to pnni10(5) or auto(2). When this object is set to auto(2), the signaling entity will start running with UNI 3.1 and learn the correct version through ILMI. |
| INT atmPortLogConfigStatus | 1.3.6.1.4.1.930.2.2.1.5.3.1.4 | INTEGER | read-write | This object is used to add, modify or delete a logical link. A value of other(1) will be returned for read operations on logical links. The value add(3) is written when setting up a new link and modify(4) is used for modifying an existing link. The value remove(5) is used to release the link. |
| ENA atmPortLogConfigStatusEnquiryEnable | 1.3.6.1.4.1.930.2.2.1.5.3.1.11 | EnableIndicator | read-write | This object is used to enable or disable the Status enquiry. Note that this parametwer is used only if the ATM signalling is enabled. |
| atmPortLogConfigTable | 1.3.6.1.4.1.930.2.2.1.5.3 | not-accessible | ATM Logical link Configuration Table. | |
| INT atmPortLogConfigTimerT309 | 1.3.6.1.4.1.930.2.2.1.5.3.1.12 | INTEGER | read-write | Timer value of timer T309.T309 is a SAAL disconnect timer. The T309 timer is started when SAAL disconnect is sent and it is stopped when SAAL disconnect is sent. When the timer is expired internal connection will be cleared and virtual calls will be released. |
| INT atmPortLogConfigVPI | 1.3.6.1.4.1.930.2.2.1.5.3.1.3 | INTEGER | read-only | This field indicates ATM virtual path identifier. |
| INT atmPortLoopTimingEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.4 | INTEGER | read-write | This field indicates if loop timing is enabled or disabled. 2=Disable, 1=Enable. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortPortIndex | 1.3.6.1.4.1.930.2.2.1.3.1.1.2 | INTEGER | read-write | This field indicates ATM port id. |
| INT atmPortRemoteLoopEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.9 | INTEGER | read-write | This field indicates if loop timing is enabled or disabled. 2=Disable, 1=Enable. When the port is disabled, no cell traffic will be ggenerated nor accepted and not SONET signal is generated. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortScramblingEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.11 | INTEGER | read-write | This field indicates if scrambing is enabled or disabled. 2=Disable, 1=Enable. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortSigEntityRole | 1.3.6.1.4.1.930.2.2.1.3.1.1.13 | INTEGER | read-write | This object indicates the role of the signalling entity that is associated with this ATM port. When the object atmPortSigEntity is set to a value other than uni(2), this object is set to other(1). Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortSigEntityType | 1.3.6.1.4.1.930.2.2.1.3.1.1.12 | INTEGER | read-write | This object indicates the type of the siganlling entity that is associated with this ATM port. The type of a signalling instance can either be no signalling, UNI which is the User-Network Interface, or Network- Network Interface iisp(3). Note that there are more than one NNI supported by the ATM Forum and we support only IISP. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortSigIlmi | 1.3.6.1.4.1.930.2.2.1.3.1.1.15 | INTEGER | read-write | This object is used to enable/disable ILMI. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortSigVersion | 1.3.6.1.4.1.930.2.2.1.3.1.1.14 | INTEGER | read-write | This object indicates the version of the siganlling entity that is associated with this ATM port. This object is always set to other(1) when the object atmPortSigEntityType is set to a value other than uni(2). When the value of this object is set to auto(2), the signalling entity will start running with UNI 3.1 and learn the correct version through ILMI. Exception: this field is read-only for 5782 Goldfish Module. That is, the user is not allowed to configure the port on this module. |
| INT atmPortSscopStatus | 1.3.6.1.4.1.930.2.2.1.3.1.1.17 | INTEGER | read-only | Indicates the operational status of the service specific connection-oriented protocol ( SSCOP ). SSCOP's function is to correct transmission errors or losses by selectively retransmitting the missing frames. down - Indicates that the peer protocol has failed to respond to the max number of status polls by its peer. up - Indicates the peer protocol is responding to the status polls. other - is an undetermined state of the SSCOP peer protocol. |
| ENA atmPortStatusEnquiryEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.18 | EnableIndicator | read-write | This object is used to enable or disable the Status enquiry for this logical link. The default value for this object is enabled except for the UNI links. Note that this parameter is used only if the ATM signalling is enabled. |
| INT atmPortTimerT309 | 1.3.6.1.4.1.930.2.2.1.3.1.1.19 | INTEGER | read-write | Timer value of timer T309.T309 is a SAAL disconnect timer. The T309 timer is started when SAAL disconnect is sent and it is stopped when SAAL disconnect is sent. When the timer is expired internal connection will be cleared and virtual calls will be released. |
| INT atmPortTrafficShapingEnable | 1.3.6.1.4.1.930.2.2.1.3.1.1.20 | INTEGER | read-write | This field indicates if traffic shaping for the ATM port is enabled or disabled. When traffic shaping is disabled, the port operates at full wire rate. When traffic shaping is enabled, the port will operate at the configured rate or available pacing rate. |
| atmSysConfig | 1.3.6.1.4.1.930.2.2.1.4 | |||
| INT atmSysSigEnable | 1.3.6.1.4.1.930.2.2.1.4.1 | INTEGER | read-write | This object is used to enable or disable the ATM signalling task within the switch. Note that by disabling the ATM signalling, the switch will not be able to support any ATM applications such as the LAN Emulation Client. The default of this value is disable. |
RFC description
Nortel Centillion ATM network configuration and ELAN setup management.
Start monitoring Bay Networks Centillion ATM switches (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.