| OID symbolic | OID numeric | Type | Access | Description |
| cadTimeMib | 1.3.6.1.4.1.4998.1.1.5.2 | | | This MIB contains objects for controlling and reporting on the various Time of Day
Services in the Cadant C4 CMTS. These Time of Day services include the TOD protocol,
the NTP protocol, and manual configuration. |
| cadClock | 1.3.6.1.4.1.4998.1.1.5.2.1 | | | |
| STR cadTimeZone | 1.3.6.1.4.1.4998.1.1.5.2.1.1 | DisplayString | read-write | Canonical TZ location name or GMT offset in hours and optionally
minutes. Setting this object causes the active TZ and DST rules
to change in the local time of day clock. |
| T/F cadIsDST | 1.3.6.1.4.1.4998.1.1.5.2.1.2 | TruthValue | read-only | If true, then cadLocalDateAndTime is in Daylight Savings Time mode.
If false, then cadLocalDateAndTime is expressed in standard time. |
| STR cadTZAbbrev | 1.3.6.1.4.1.4998.1.1.5.2.1.3 | DisplayString | read-only | Current TZ abbreviation based on either the TZ rules or a GMT
offset, e.g. CST, CDT, GMT+2, GMT-3:30, GMT |
| DAT cadLocalDateAndTime | 1.3.6.1.4.1.4998.1.1.5.2.1.4 | DateAndTime | read-only | CMTS local date and time displayed as
yyyy-mm-dd,hh:mm:ss.d,+/-hh:mm, where the date is yyyy-mmmm-dd and
time in deci-seconds is hh:mm:ss.d, adn teh current offset from
GMT is +/-hh:mm. This object is adjusted by teh TZ and DST rules.
E.g. 2002-5-26,13;30:15.0,-4:0 |
| U32 cadLocalTime | 1.3.6.1.4.1.4998.1.1.5.2.1.5 | Unsigned32 | read-only | CMTS local date and time displayed as a 32-bit number of
seconds since teh epoch Jan. 1, 1970. This object is adjusted
by the current TZ and DST rules. |
| U32 cadUTCtime | 1.3.6.1.4.1.4998.1.1.5.2.1.6 | Unsigned32 | read-write | UTC (GMT) time mainted by the CMTS local time of day clock
represented as a 32-bit number of seconds since the epoch
Jan. 1, 1970. If NetTimeSyncProto is TOD(1) or NTP(2) then this
value is maintained by the network time sync protocol and
any attempt to change this object is ignored. If NetTimeSyncProto
is None(0), then the local time of day clock may be set manually
via this object. |
| INT cadNetTimeSyncProto | 1.3.6.1.4.1.4998.1.1.5.2.1.7 | INTEGER | read-write | Active network time synchronization protocol to be used by this
managed device. |
| cadTod | 1.3.6.1.4.1.4998.1.1.5.2.2 | | | |
| IP cadTodServerIpAddress | 1.3.6.1.4.1.4998.1.1.5.2.2.1 | IpAddress | read-write | If cadNetTimeSyncProto is tod(1), then this object is used as
to provide the IPv4 address of the network TOD server. |
| INT cadTodServerConnType | 1.3.6.1.4.1.4998.1.1.5.2.2.2 | INTEGER | read-write | If cadNetTimeSyncProto is tod(1), then this object is used as
to provide the connection type for communitcating with the
server specified in cadTodServerIpAddress. |
| cadNtp | 1.3.6.1.4.1.4998.1.1.5.2.3 | | | |
| I32 cadNtpVersionDefault | 1.3.6.1.4.1.4998.1.1.5.2.3.1 | Integer32 | read-write | Default NTP version used when sending messages to NTP
clients, servers, or peers. |
| T/F cadNtpAuthenticate | 1.3.6.1.4.1.4998.1.1.5.2.3.2 | TruthValue | read-write | If set to true(1), then all NTP operations will require
authentication keys. Otherwise, if false(2), then NTP
authentication is not required. |
| CAD cadNtpClockDrift | 1.3.6.1.4.1.4998.1.1.5.2.3.3 | CadDouble | read-only | The latest SCM local clock drift value. This value is
used when restarting the NTP daemon process. |
| cadNtpSource | 1.3.6.1.4.1.4998.1.1.5.2.3.10 | | | |
| I32 cadNtpSourceMinPollDefault | 1.3.6.1.4.1.4998.1.1.5.2.3.10.1 | Integer32 | read-write | Default minimum polling interval for NTP clients and
peers. This object is expressed is powers of 2 seconds
in the range of 4 through 11, for an effective minimum
polling interval of between 16 and 2048 seconds. This
object may not be set to a value greater than
cadNtpSourceMaxPollDefault. The value in this object is
ignored if cadNtpSourceMinPoll is non-zero. |
| I32 cadNtpSourceMaxPollDefault | 1.3.6.1.4.1.4998.1.1.5.2.3.10.2 | Integer32 | read-write | Default maximum polling interval for NTP clients and
peers. This object is expressed is powers of 2 seconds
in the range of 4 through 11, for an effective minimum
polling interval of between 16 and 2048 seconds. This
object may not be set to a value less than
cadNtpSourceMinPollDefault. The value in this object is
ignored if cadNtpSourceMaxPoll is non-zero. |
| cadNtpSourceTable | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10 | | not-accessible | Configuration and display table for NTP servers and/or peers. |
| cadNtpSourceEntry | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1 | | not-accessible | Each entry represents an association this device has with
an NTP server or peer. |
| IP cadNtpSourceIpAddress | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.1 | IpAddress | not-accessible | The IPv4 address associated with this NTP server or peer. |
| INT cadNtpSourceType | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.2 | INTEGER | read-create | This table may only contain entries of one type.
Attempts to create additional rows which have a
cadNtpSourceType different from the other rows will
fail. |
| T/F cadNtpSourceBurstEnabled | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.3 | TruthValue | read-create | If set to true(1), then burst mode is enabled. If
set to false(2), then burst mode is disabled. |
| T/F cadNtpSourcePreferred | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.4 | TruthValue | read-create | If set to true(1), then this NTP server or peer entry
is a preferred server or peer and will be considered
before other non-preferred servers or peers, even if those
other servers or peers have a better/lower Stratum value. |
| U32 cadNtpSourceAuthKeyId | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.5 | Unsigned32 | read-create | The id-id of the MD5 authentication key-string as
stored in the cadNtpAuthKeyTable. A value of 0 for
this object denotes that no authentication is to
be used for communication. |
| I32 cadNtpSourceMinPoll | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.6 | Integer32 | read-create | If non-zero, this will override cadNtpMinPoll. See
the DESCRIPTION of cadNtpMinPoll for more details. |
| I32 cadNtpSourceMaxPoll | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.7 | Integer32 | read-create | If non-zero, this will override cadNtpMaxPoll. See
the DESCRIPTION of cadNtpMaxPoll for more details. |
| I32 cadNtpSourceVersion | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.8 | Integer32 | read-create | The version of NTP used when sending messages
to this server or peer. Setting this to 2, 3, or 4 will
override the cadNtpVersion default value. Setting
this object to 0 will cause the value in cadNtpVersion
to be used for this server or peer. |
| I32 cadNtpSourceTtl | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.9 | Integer32 | read-create | The Time-To-Live (TTL) value used in the IP header
when trying to locate nearby members of its manycast
group. This object is only applicable for rows which
have a cadNtpSourceType value of either manycastServer(4)
or manycastPeer(6). |
| ROW cadNtpSourceRowStatus | 1.3.6.1.4.1.4998.1.1.5.2.3.10.10.1.10 | RowStatus | read-create | Control object for this row. The only values supported
by the C4 CMTS are active(1), createAndGo(4), and destroy(6).
Setting this object to createAndGo(4) will cause the row
to be created. Reading this object should always return
active(1). Setting this object to destroy(6) will remove
the row from the C4 CMTS. |
| cadNtpAuthKeyTable | 1.3.6.1.4.1.4998.1.1.5.2.3.30 | | not-accessible | Table for provisioning NTP authentication keys |
| cadNtpAuthKeyEntry | 1.3.6.1.4.1.4998.1.1.5.2.3.30.1 | | not-accessible | Each entry represents an NTP authentication key. |
| U32 cadNtpAuthKeyId | 1.3.6.1.4.1.4998.1.1.5.2.3.30.1.1 | Unsigned32 | not-accessible | The ID of this NTP authentication key |
| INT cadNtpAuthKeyType | 1.3.6.1.4.1.4998.1.1.5.2.3.30.1.2 | INTEGER | read-create | The type of key this row represents. Future versions
may support more authentication algorithms than MD5. |
| STR cadNtpAuthKeyValue | 1.3.6.1.4.1.4998.1.1.5.2.3.30.1.3 | DisplayString | read-create | The ASCII value of this key |
| ROW cadNtpAuthKeyRowStatus | 1.3.6.1.4.1.4998.1.1.5.2.3.30.1.4 | RowStatus | read-create | Control object for this row |