All MIBs › BLDG-HVAC-MIB › bldgHVACCoolOrHeatMins
bldgHVACCoolOrHeatMins
Module: BLDG-HVAC-MIB
OID (symbolic): BLDG-HVAC-MIB::bldgHVACCoolOrHeatMins
OID (numeric): 1.3.6.1.3.122.1.1.1.6
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The total number of heating or cooling minutes that have been consumed since the row was activated. Notice that whether the minutes represent heating or cooling is a function of the configuration of this row. If the system is re-initialized from a cooling to heating function or vice versa, then the counter would start over again. This effect is similar to a reconfiguration of some network interface cards. When parameters that impact configuration are changed, the subsystem must be re-initialized. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of bldgHVACDiscontinuityTime.
What is bldgHVACCoolOrHeatMins?
Reports the cumulative number of minutes the HVAC system has spent actively heating or cooling a room since the configuration row was activated. Whether the minutes represent heating or cooling depends on how the row is configured, and the counter resets if the system switches between the two modes.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.3.122.1.1.1.6 snmpwalk -v2c -c public <target> BLDG-HVAC-MIB::bldgHVACCoolOrHeatMins
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.3.122.1.1.1.6.1 snmpget -v2c -c public <target> BLDG-HVAC-MIB::bldgHVACCoolOrHeatMins.1
Start monitoring Building HVAC control units/BMS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the BLDG-HVAC-MIB::bldgHVACCoolOrHeatMins OID value, configure state conditions and alerts, and monitor any Building HVAC control units/BMS from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (5 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.3 | experimental | APERTUS-NPG-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.3.122 | bldgHVACMIB | BLDG-HVAC-MIB |
| 1.3.6.1.3.122.1 | bldgHVACObjects | BLDG-HVAC-MIB |
| 1.3.6.1.3.122.1.1 | bldgHVACTable | BLDG-HVAC-MIB |
| 1.3.6.1.3.122.1.1.1 | bldgHVACEntry | BLDG-HVAC-MIB |
| 1.3.6.1.3.122.1.1.1.6 | bldgHVACCoolOrHeatMins | BLDG-HVAC-MIB |