| OID symbolic | OID numeric | Type | Access | Description |
| mibhdsl2NetworkProfile | 1.3.6.1.4.1.529.23.14 | | | |
| mibhdsl2NetworkProfileTable | 1.3.6.1.4.1.529.23.14.1 | | not-accessible | A list of mibhdsl2NetworkProfile profile entries. |
| mibhdsl2NetworkProfileEntry | 1.3.6.1.4.1.529.23.14.1.1 | | not-accessible | A mibhdsl2NetworkProfile entry containing objects that
maps to the parameters of mibhdsl2NetworkProfile profile. |
| INT hdsl2NetworkProfile_Shelf_o | 1.3.6.1.4.1.529.23.14.1.1.1 | INTEGER | read-only | |
| INT hdsl2NetworkProfile_Slot_o | 1.3.6.1.4.1.529.23.14.1.1.2 | INTEGER | read-only | |
| INT hdsl2NetworkProfile_Item_o | 1.3.6.1.4.1.529.23.14.1.1.3 | INTEGER | read-only | |
| STR hdsl2NetworkProfile_Name | 1.3.6.1.4.1.529.23.14.1.1.4 | DisplayString | read-write | For future use. The current design does not use the name field but instead references Hdsl2 lines by the physical address; we may in the future support referencing Hdsl2 lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Hdsl2 line physical address. |
| INT hdsl2NetworkProfile_PhysicalAddress_Shelf | 1.3.6.1.4.1.529.23.14.1.1.5 | INTEGER | read-write | The number of the shelf that the addressed physical device resides on. |
| INT hdsl2NetworkProfile_PhysicalAddress_Slot | 1.3.6.1.4.1.529.23.14.1.1.6 | INTEGER | read-write | The number of the slot that the addressed physical device resides on. |
| INT hdsl2NetworkProfile_PhysicalAddress_ItemNumber | 1.3.6.1.4.1.529.23.14.1.1.7 | INTEGER | read-write | A number that specifies an addressable entity within the context of shelf and slot. |
| INT hdsl2NetworkProfile_Enabled | 1.3.6.1.4.1.529.23.14.1.1.8 | INTEGER | read-write | TRUE if the line is enabled, otherwise FALSE. |
| INT hdsl2NetworkProfile_ProfileNumber | 1.3.6.1.4.1.529.23.14.1.1.9 | INTEGER | read-write | For potential backwards compatibility. The current design consists of one line profile numbered 0. |
| INT hdsl2NetworkProfile_LineConfig_TrunkGroup | 1.3.6.1.4.1.529.23.14.1.1.10 | INTEGER | read-write | The trunk group to which this line is assigned. 0 means this line is not part of a trunk group. |
| INT hdsl2NetworkProfile_LineConfig_NailedGroup | 1.3.6.1.4.1.529.23.14.1.1.11 | INTEGER | read-write | A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group. |
| INT hdsl2NetworkProfile_LineConfig_VpSwitchingVpi | 1.3.6.1.4.1.529.23.14.1.1.12 | INTEGER | read-write | The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY. |
| INT hdsl2NetworkProfile_LineConfig_RoutePort_SlotNumber_SlotNumber | 1.3.6.1.4.1.529.23.14.1.1.13 | INTEGER | read-write | |
| INT hdsl2NetworkProfile_LineConfig_RoutePort_SlotNumber_ShelfNumber | 1.3.6.1.4.1.529.23.14.1.1.14 | INTEGER | read-write | TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed. |
| INT hdsl2NetworkProfile_LineConfig_RoutePort_RelativePortNumber_RelativePortNumber | 1.3.6.1.4.1.529.23.14.1.1.15 | INTEGER | read-write | |
| INT hdsl2NetworkProfile_LineConfig_Activation | 1.3.6.1.4.1.529.23.14.1.1.16 | INTEGER | read-write | Line activation mode. |
| INT hdsl2NetworkProfile_LineConfig_CallRouteInfo_Shelf | 1.3.6.1.4.1.529.23.14.1.1.17 | INTEGER | read-write | The number of the shelf that the addressed physical device resides on. |
| INT hdsl2NetworkProfile_LineConfig_CallRouteInfo_Slot | 1.3.6.1.4.1.529.23.14.1.1.18 | INTEGER | read-write | The number of the slot that the addressed physical device resides on. |
| INT hdsl2NetworkProfile_LineConfig_CallRouteInfo_ItemNumber | 1.3.6.1.4.1.529.23.14.1.1.19 | INTEGER | read-write | A number that specifies an addressable entity within the context of shelf and slot. |
| INT hdsl2NetworkProfile_LineConfig_UnitType | 1.3.6.1.4.1.529.23.14.1.1.20 | INTEGER | read-write | The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation. |
| INT hdsl2NetworkProfile_Action_o | 1.3.6.1.4.1.529.23.14.1.1.23 | INTEGER | read-write | |
| INT hdsl2NetworkProfile_SparingMode | 1.3.6.1.4.1.529.23.14.1.1.24 | INTEGER | read-write | Port sparing operational mode for this port. |
| INT hdsl2NetworkProfile_LineConfig_NtrEnabled | 1.3.6.1.4.1.529.23.14.1.1.25 | INTEGER | read-write | TRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the remote CPE port to recover the clock. If the unit-type is CPE, it will allow the port to possibly output the recovered clock as the system clock (if elected, see clock-source and clock-priority fields) when NTR is enabled. |
| INT hdsl2NetworkProfile_LineConfig_ClockSource | 1.3.6.1.4.1.529.23.14.1.1.26 | INTEGER | read-write | Determine whether the 8KHz clock from the HDSL2 line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock source. |
| INT hdsl2NetworkProfile_LineConfig_ClockPriority | 1.3.6.1.4.1.529.23.14.1.1.27 | INTEGER | read-write | Clock priority assigned to the HDSL2 line. Used to select a particular HDSL2 line as the 8KHz system clock source. |
| INT hdsl2NetworkProfile_LineConfig_LoopBack | 1.3.6.1.4.1.529.23.14.1.1.28 | INTEGER | read-write | Configuration of different modem loopbacks. |
| INT hdsl2NetworkProfile_IgnoreLineup | 1.3.6.1.4.1.529.23.14.1.1.29 | INTEGER | read-write | Ignore line up value for this port. |
| INT hdsl2NetworkProfile_LineConfig_Margin | 1.3.6.1.4.1.529.23.14.1.1.30 | INTEGER | read-write | Selects a margin range between the signal to noise floor. |
| INT hdsl2NetworkProfile_LineConfig_RateMode | 1.3.6.1.4.1.529.23.14.1.1.31 | INTEGER | read-write | Used for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode. |
| INT hdsl2NetworkProfile_LineConfig_MinRate | 1.3.6.1.4.1.529.23.14.1.1.32 | INTEGER | read-write | Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to. |
| INT hdsl2NetworkProfile_LineConfig_MaxRate | 1.3.6.1.4.1.529.23.14.1.1.33 | INTEGER | read-write | Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is the only rate the mode trains to. |
| INT hdsl2NetworkProfile_LineConfig_GshdslStandardNetworkType | 1.3.6.1.4.1.529.23.14.1.1.34 | INTEGER | read-write | Per the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard network types. The setting of auto-detect is only valid for CPE to train off of COE Standard Network settings. |
| INT hdsl2NetworkProfile_LineConfig_GshdslPsdType | 1.3.6.1.4.1.529.23.14.1.1.35 | INTEGER | read-write | Per the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 776kbps, 784kbps, 1544kbps, or 1552kbps for Annex A networks. Annex B networks support fixed rates of 2056kbps or 2304kbps. The setting of auto-detect is only valid for CPE to train off of COE PSD settings. |
| STR hdsl2NetworkProfile_ThreshProfiles_SpanThreshProfile | 1.3.6.1.4.1.529.23.14.1.1.36 | DisplayString | read-write | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for all the HDSL2/SHDSL units for this port unless otherwise specified by the individual parameters in this subprofile. |
| STR hdsl2NetworkProfile_ThreshProfiles_XtucThreshProfile | 1.3.6.1.4.1.529.23.14.1.1.37 | DisplayString | read-write | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the DSLAM. |
| STR hdsl2NetworkProfile_ThreshProfiles_XturThreshProfile | 1.3.6.1.4.1.529.23.14.1.1.38 | DisplayString | read-write | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the remote CPE. |
| INT hdsl2NetworkProfile_LineConfig_SnextMargin | 1.3.6.1.4.1.529.23.14.1.1.39 | INTEGER | read-write | Selects a Snext margin range with a worst-case self next noise model given current loop insertion loss. |
| INT hdsl2NetworkProfile_LineConfig_AnnexbAnfpEnabled | 1.3.6.1.4.1.529.23.14.1.1.40 | INTEGER | read-write | TRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. This field makes the modem perform in Annex B mode, but slightly differently. This is to comply with the UK ANFP requirements and pass the BTexact Technologies PSD measurement technique to meet BT approval. Only enable this field for that test specifically. |
| mibhdsl2NetworkProfile_ThreshProfiles_UnitThreshProfilesTable | 1.3.6.1.4.1.529.23.14.2 | | not-accessible | A list of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile entries. |
| mibhdsl2NetworkProfile_ThreshProfiles_UnitThreshProfilesEntry | 1.3.6.1.4.1.529.23.14.2.1 | | not-accessible | A mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles entry containing objects that maps to the parameters of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile. |
| INT hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_Shelf_o | 1.3.6.1.4.1.529.23.14.2.1.1 | INTEGER | read-only | |
| INT hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_Slot_o | 1.3.6.1.4.1.529.23.14.2.1.2 | INTEGER | read-only | |
| INT hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_Item_o | 1.3.6.1.4.1.529.23.14.2.1.3 | INTEGER | read-only | |
| INT hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_Index_o | 1.3.6.1.4.1.529.23.14.2.1.4 | INTEGER | read-only | |
| STR hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_XruNetThreshProfile | 1.3.6.1.4.1.529.23.14.2.1.5 | DisplayString | read-write | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the network side of regenerator unit 1. |
| STR hdsl2NetworkProfile_ThreshProfiles_UnitThreshProfiles_XruCustThreshProfile | 1.3.6.1.4.1.529.23.14.2.1.6 | DisplayString | read-write | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the customer side of regenerator unit 1. |