| OID symbolic | OID numeric | Type | Access | Description |
| INT cltmCmd_Action_o | 1.3.6.1.4.1.529.23.66.1.1.42 | INTEGER | read-write | |
| INT cltmCmd_BackgroundNoiseFilter | 1.3.6.1.4.1.529.23.66.1.1.8 | INTEGER | read-write | Line Filter Type for Background Noise Test. |
| INT cltmCmd_BackgroundNoiseTermination | 1.3.6.1.4.1.529.23.66.1.1.9 | INTEGER | read-write | Line Termination Type for Background Noise Test. |
| INT cltmCmd_BtapMeasureLength | 1.3.6.1.4.1.529.23.66.1.1.41 | INTEGER | read-write | Measurement length (100 - 20000 ft. or 32 - 6097 meter). |
| INT cltmCmd_BtapStartLength | 1.3.6.1.4.1.529.23.66.1.1.40 | INTEGER | read-write | Measurement start length (15 - 20000 ft. or 5 - 6097 meter). |
| INT cltmCmd_CalibrationType | 1.3.6.1.4.1.529.23.66.1.1.17 | INTEGER | read-write | Calibration Type |
| INT cltmCmd_CltmSlot | 1.3.6.1.4.1.529.23.66.1.1.2 | INTEGER | read-only | Identify the CLTM slot within the system. |
| INT cltmCmd_CtoneTone | 1.3.6.1.4.1.529.23.66.1.1.36 | INTEGER | read-write | Control tone, type of Tone (QUIET, RESTORE). |
| INT cltmCmd_CtoneType | 1.3.6.1.4.1.529.23.66.1.1.35 | INTEGER | read-write | Control tone, type of DSL service (ADSL, GLITE). |
| INT cltmCmd_DmmallInputImp | 1.3.6.1.4.1.529.23.66.1.1.34 | INTEGER | read-write | Input Impedance (100, 1000 Kohm). |
| INT cltmCmd_DmmallPeriod | 1.3.6.1.4.1.529.23.66.1.1.33 | INTEGER | read-write | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| INT cltmCmd_DmmallType | 1.3.6.1.4.1.529.23.66.1.1.32 | INTEGER | read-write | DMM Measurement Type. |
| INT cltmCmd_DmmcapPeriod | 1.3.6.1.4.1.529.23.66.1.1.31 | INTEGER | read-write | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| INT cltmCmd_DmmdcdImpedance | 1.3.6.1.4.1.529.23.66.1.1.30 | INTEGER | read-write | Output Impedance to be used (10 to 1000 Kohms). |
| INT cltmCmd_DmmdcdPeriod | 1.3.6.1.4.1.529.23.66.1.1.28 | INTEGER | read-write | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
| INT cltmCmd_DmmdcdVoltage | 1.3.6.1.4.1.529.23.66.1.1.29 | INTEGER | read-write | Test voltage to be used (-230 to 230 Volts). |
| INT cltmCmd_DmmLead | 1.3.6.1.4.1.529.23.66.1.1.7 | INTEGER | read-write | DMM Measurement Leads. |
| INT cltmCmd_DmmType | 1.3.6.1.4.1.529.23.66.1.1.6 | INTEGER | read-write | DMM Measurement Type. |
| INT cltmCmd_FcllocGauge | 1.3.6.1.4.1.529.23.66.1.1.44 | INTEGER | read-write | FCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| INT cltmCmd_FcllocUnit | 1.3.6.1.4.1.529.23.66.1.1.43 | INTEGER | read-write | Measurement System for FCLLOC Test. |
| INT cltmCmd_ImpulseNoiseStartDeadTime | 1.3.6.1.4.1.529.23.66.1.1.15 | INTEGER | read-write | Dead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments. |
| INT cltmCmd_ImpulseNoiseStartDelta | 1.3.6.1.4.1.529.23.66.1.1.13 | INTEGER | read-write | Delta Value for Impulse Noise Test. The delta range is 2-6 dB |
| INT cltmCmd_ImpulseNoiseStartMaxCount | 1.3.6.1.4.1.529.23.66.1.1.14 | INTEGER | read-write | Max Count for Impulse Noise Test. The range of the value is 1-1999. |
| INT cltmCmd_ImpulseNoiseStartThresh | 1.3.6.1.4.1.529.23.66.1.1.12 | INTEGER | read-write | Threshold for Impulse Noise Test. The Range is 50-100 dBrm. |
| INT cltmCmd_ImpulseNoiseStartTimer | 1.3.6.1.4.1.529.23.66.1.1.16 | INTEGER | read-write | Timer values for Impulse Noise Start Test. The value is assigned in 1 minute increment. |
| INT cltmCmd_Index_o | 1.3.6.1.4.1.529.23.66.1.1.1 | INTEGER | read-only | |
| INT cltmCmd_LoopResistanceTemp | 1.3.6.1.4.1.529.23.66.1.1.11 | INTEGER | read-write | Line Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit. |
| INT cltmCmd_LoopResistanceUnit | 1.3.6.1.4.1.529.23.66.1.1.10 | INTEGER | read-write | Measurement System for Loop Resistance Test. |
| INT cltmCmd_ShortlocGauge | 1.3.6.1.4.1.529.23.66.1.1.46 | INTEGER | read-write | SHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| INT cltmCmd_ShortlocType | 1.3.6.1.4.1.529.23.66.1.1.47 | INTEGER | read-write | SHORTLOC test type. |
| INT cltmCmd_ShortlocUnit | 1.3.6.1.4.1.529.23.66.1.1.45 | INTEGER | read-write | Measurement System for SHORTLOC Test. |
| INT cltmCmd_TdrAvg | 1.3.6.1.4.1.529.23.66.1.1.24 | INTEGER | read-write | Number of trials to get the avarage. |
| INT cltmCmd_TdrGauge | 1.3.6.1.4.1.529.23.66.1.1.22 | INTEGER | read-write | TDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
| INT cltmCmd_TdrGetType | 1.3.6.1.4.1.529.23.66.1.1.25 | INTEGER | read-write | TDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set. |
| INT cltmCmd_TdrMeasurementLength | 1.3.6.1.4.1.529.23.66.1.1.27 | INTEGER | read-write | TDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) for the metric system. |
| INT cltmCmd_TdrStartDistance | 1.3.6.1.4.1.529.23.66.1.1.26 | INTEGER | read-write | TDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the metric system. |
| INT cltmCmd_TdrUnit | 1.3.6.1.4.1.529.23.66.1.1.21 | INTEGER | read-write | Measurement System for TDR Test. |
| INT cltmCmd_TdrVp | 1.3.6.1.4.1.529.23.66.1.1.23 | INTEGER | read-write | TDR VP as percentage of the speed of light. |
| INT cltmCmd_TestOperation | 1.3.6.1.4.1.529.23.66.1.1.5 | INTEGER | read-write | The current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure. |
| INT cltmCmd_TestSequence | 1.3.6.1.4.1.529.23.66.1.1.4 | INTEGER | read-only | Sequence of the last issued test command. |
| INT cltmCmd_TestTimeStamp | 1.3.6.1.4.1.529.23.66.1.1.3 | INTEGER | read-only | Value of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are changed. |
| INT cltmCmd_ToneSendFreq | 1.3.6.1.4.1.529.23.66.1.1.18 | INTEGER | read-write | Tone Send Frequency in KHz. |
| INT cltmCmd_ToneSendLevel | 1.3.6.1.4.1.529.23.66.1.1.19 | INTEGER | read-write | Tone Send Level in dBm. |
| INT cltmCmd_ToneSendPeriod | 1.3.6.1.4.1.529.23.66.1.1.20 | INTEGER | read-write | Amount of time a tone is sent (1-20 Minutes). |
| INT cltmCmd_TtoneLead | 1.3.6.1.4.1.529.23.66.1.1.37 | INTEGER | read-write | trace tone, Measurement Leads. |
| INT cltmCmd_TtoneLevel | 1.3.6.1.4.1.529.23.66.1.1.38 | INTEGER | read-write | trace tone, Tone Send Level in dBm. |
| INT cltmCmd_TtonePeriod | 1.3.6.1.4.1.529.23.66.1.1.39 | INTEGER | read-write | trace tone, Amount of time a tone is sent (1-20 Minutes). |
| mibcltmCmd | 1.3.6.1.4.1.529.23.66 | | | |
| mibcltmCmdEntry | 1.3.6.1.4.1.529.23.66.1.1 | | not-accessible | A mibcltmCmd entry containing objects that
maps to the parameters of mibcltmCmd profile. |
| mibcltmCmdTable | 1.3.6.1.4.1.529.23.66.1 | | not-accessible | A list of mibcltmCmd profile entries. |