All MIBs › ARISTA-PFC-MIB
Organization: Arista Networks, Inc.
Last Updated: 2014-08-15
Category: Vendor: Arista
Description: Arista EOS priority-based flow control (PFC) configuration and per-priority statistics.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ARISTA-PFC-MIB?
ARISTA-PFC-MIB is a proprietary Arista Networks module extending the standards-based IEEE8021-PFC-MIB with per-class-of-service detail for IEEE 802.1Qbb Priority-based Flow Control on Arista switches, a mechanism used in lossless Ethernet fabrics such as those carrying FCoE or RoCE traffic. It exposes a per-interface, per-priority table of PFC pause frame requests and indications. This is a performance/congestion monitoring module: rising PFC counters on a given priority reveal that a specific traffic class is experiencing backpressure, which can signal downstream congestion or a misconfigured lossless-traffic class. It has an explicit and notable dependency on the standard IEEE8021-PFC-MIB, which it extends rather than replaces. It is deployed on Arista data center switches running converged/lossless Ethernet fabrics where priority flow control is enabled for storage or RDMA traffic. Engineers can download the ARISTA-PFC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ARISTA-PFC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Arista Networks EOS switch (data center/lossless Ethernet fabric)
Monitoring Examples
An operator would poll aristaPfcPriorityTable, indexed by aristaPfcIfIndex and aristaPfcPriorityIndex, reading aristaPfcPriorityRequests and aristaPfcPriorityIndications to see how often PFC pause frames were sent or received for a given priority class on an interface. A steadily climbing aristaPfcPriorityIndications count on a specific priority would indicate that downstream congestion is repeatedly triggering flow-control pauses for that traffic class, potentially causing latency spikes for storage or RDMA applications relying on lossless delivery.
What Can Be Monitored
- per-priority PFC pause requests
- per-priority PFC pause indications
- per-interface flow control activity by class of service
Imported Objects
From ARISTA-SMI-MIB
| aristaMibs | OBJECT-IDENTITY |
From IF-MIB
| InterfaceIndex |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter64 | |
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| TEXTUAL-CONVENTION |
How to Use in IPNetwork Monitor
Example using aristaPfcPriorityRequests OID:
OIDs
RFC description
Extensions for managing IEEE 802.1Qbb Priority-based Flow Control on Arista devices with per class-of-service information.
Start monitoring Arista Networks EOS switches with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.