| OID symbolic | OID numeric | Type | Access | Description |
| alcatelIND1StackMgrMIB | 1.3.6.1.4.1.6486.801.1.2.1.24.1 | | | This module describes an authoritative enterprise-specific Simple
Network Management Protocol (SNMP) Management Information Base (MIB):
For the Birds Of Prey Product Line
Stack Manager
The right to make changes in specification and other information
contained in this document without prior notice is reserved.
No liability shall be assumed for any incidental, indirect, special, or
consequential damages whatsoever arising from or related to this
document or the information contained herein.
Vendors, end-users, and other interested parties are granted
non-exclusive license to use this specification in connection with
management of the products for which it is intended to be used.
Copyright (C) 1995-2007 Alcatel-Lucent
ALL RIGHTS RESERVED WORLDWIDE |
| alcatelIND1StackMgrMIBObjects | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1 | | | |
| alaStackMgrChassisTable | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1 | | not-accessible | Maintains a list with information about all the switches
that participate on the stack herein refered to as chassis. |
| alaStackMgrChassisEntry | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1 | | not-accessible | Each entry corresponds to a chassis and lists its role and
neighbors in the stack. |
| ALA alaStackMgrSlotNINumber | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.1 | AlaStackMgrNINumber | read-only | Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: swicthes operating in pass through mode
- 255: unassigned slot number. |
| INT alaStackMgrSlotCMMNumber | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.2 | INTEGER | read-only | The numbers allocated for the stack CMMs are from 65..72 or 0 if not present |
| ALA alaStackMgrChasRole | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.3 | AlaStackMgrSlotRole | read-only | The current role of the chassis as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5). |
| ALA alaStackMgrLocalLinkStateA | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.4 | AlaStackMgrLinkStatus | read-only | 1 indicates that the stacking link A is up, which means it knows its adjacent node.
2 indicates that the stacking link A is inactive and RemoteNISlotA and RemoteLinkA are not significants. |
| ALA alaStackMgrRemoteNISlotA | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.5 | AlaStackMgrNINumber | read-only | This is the remote NI slot seen by the current NI through its stacking link A.
The numbers allocated for the Stack NIs are 1..8, 1001..1008 or 0 if not present |
| ALA alaStackMgrRemoteLinkA | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.6 | AlaStackMgrLinkNumber | read-only | This is the remote link of the remote NI slot seen through the stacking link A.
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52. |
| ALA alaStackMgrLocalLinkStateB | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.7 | AlaStackMgrLinkStatus | read-only | 1 indicates that the stacking link B is up, which means it knows its adjacent node.
2 indicates that the stacking link B is inactive and RemoteNISlotB and RemoteLinkB are not significants. |
| ALA alaStackMgrRemoteNISlotB | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.8 | AlaStackMgrNINumber | read-only | This is the remote NI slot seen by the current NI through its stacking link B.
The numbers allocated for the Stack NIs are 1..8, 1001..1008 or 0 if not present |
| ALA alaStackMgrRemoteLinkB | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.9 | AlaStackMgrLinkNumber | read-only | This is the remote link of the remote NI slot seen through the stacking link B.
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52. |
| ALA alaStackMgrChasState | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.10 | AlaStackMgrSlotState | read-only | This current state of the chassis: running (1), duplicateSlot (2), clearedSlot (3),
outOfSlots (4), outOfTokens (5), or badMix (6). |
| ALA alaStackMgrSavedSlotNINumber | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.11 | AlaStackMgrNINumber | read-write | Slot number stored in persistent memory that will be in effect if the stack
element reboots. Only slot numbers in the range 1..8 are allowed. |
| ALA alaStackMgrCommandAction | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.12 | AlaStackMgrCommandAction | read-write | This object identifies which of the following Actions is to be performed:
clearSlot(1), clearSlotImmediately (2) or reload (3). Whenever a new command is received,
the value of the object alaStackMgrCommandStatus will be updated accordingly. |
| ALA alaStackMgrCommandStatus | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.13 | AlaStackMgrCommandStatus | read-only | This object provides the current status of last command received from the management
as follows: notSignificant(0), clearSlotInProgress(1), clearSlotFailed(2), clearSlotSuccess(3),
setSlotInProgress(4), setSlotFailed(5) or setSlotSuccess(6).
New commands are only accepted if the value of this object is different than setSlotInProgress
and clearSlotInProgress. |
| ALA alaStackMgrOperStackingMode | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.14 | AlaStackMgrStackingMode | read-only | This object specifies the current running mode of the switch. |
| ALA alaStackMgrAdminStackingMode | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.1.1.15 | AlaStackMgrStackingMode | read-write | This object specifies the stack mode atained on reload. |
| alaStackMgrStatsTable | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2 | | not-accessible | Stack port statistics table. |
| alaStackMgrStatsEntry | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1 | | not-accessible | Stats table for stackable ports. |
| ALA alaStackMgrStatLinkNumber | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.1 | AlaStackMgrLinkNumber | read-only | Local link refers to the stacking port on each slot.
The values of these ports are:
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52. |
| C32 alaStackMgrStatPktsRxEx | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.2 | Counter32 | read-only | The total number of packets recieved on this port. |
| C32 alaStackMgrStatPktsTx | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.3 | Counter32 | read-only | The total number of packets transmitted on this port. |
| C32 alaStackMgrStatErrorsRx | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.4 | Counter32 | read-only | The total number of packets in error - received on the port. |
| C32 alaStackMgrStatErrorsTx | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.5 | Counter32 | read-only | The total number of packets in error - transmitted on the port. |
| INT alaStackMgrStatDelayFromLastMsg | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.2.1.6 | INTEGER | read-only | The delay since the last message. |
| ALA alaStackMgrStackStatus | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.3 | AlaStackMgrStackStatus | read-only | Indicates whether the Stack is or not in Loop. |
| INT alaStackMgrTokensUsed | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.4 | INTEGER | read-only | Indicates the total number of tokens that have been allocated to all the
elements in the stack. |
| INT alaStackMgrTokensAvailable | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.5 | INTEGER | read-only | Indicates the total number of tokens that are still available and that
potentially may be allocated to elements of the stack. |
| alaStackMgrStaticRouteTable | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6 | | not-accessible | Maintains a list with information about all the static
routes in the stack. |
| alaStackMgrStaticRouteEntry | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1 | | not-accessible | Each entry corresponds to a static route and lists its source and
destination in the stack. |
| NUM alaStackMgrStaticRouteSrcStartIf | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.1 | InterfaceIndex | not-accessible | The physical identification number for start source range of the static route |
| NUM alaStackMgrStaticRouteSrcEndIf | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.2 | InterfaceIndex | not-accessible | The physical identification number for end source range of the static route |
| NUM alaStackMgrStaticRouteDstStartIf | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.3 | InterfaceIndex | not-accessible | The physical identification number for start destination range of the static route |
| NUM alaStackMgrStaticRouteDstEndIf | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.4 | InterfaceIndex | not-accessible | The physical identification number for end destination range of the static route |
| ALA alaStackMgrStaticRoutePort | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.5 | AlaStackMgrLinkNumber | read-write | This is the stack link to the destination NI slot .
The values for these ports are platform dependent. The possible values are:
- 0: not present
- linkA: 25, 27, 29, 31 or 51
- linkB: 26, 28, 30, 32 or 52.
Incase of static routesthe value is either 1(STACKA) or 2(STACKB) |
| ALA alaStackMgrStaticRoutePortState | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.6 | AlaStackMgrLinkStatus | read-only | 1 indicates that the static route stacking link is up .
2 indicates that the stacking link is inactive. |
| INT alaStackMgrStaticRouteStatus | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.7 | INTEGER | read-write | Whether this static route is enabled or disabled . |
| ROW alaStackMgrStaticRouteRowStatus | 1.3.6.1.4.1.6486.801.1.2.1.24.1.1.6.1.8 | RowStatus | read-write | The status of this table entry. |
| alcatelIND1StackMgrMIBConformance | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2 | | | |
| alcatelIND1StackMgrMIBGroups | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2.1 | | | |
| alaStackMgrCfgMgrGroup | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2.1.1 | | | A collection of objects providing information about
the topology of the stack . |
| alaStackMgrNotificationGroup | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2.1.2 | | | A collection of notifications for signaling Stack manager events. |
| alcatelIND1StackMgrMIBCompliances | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2.2 | | | |
| alcatelIND1StackMgrMIBCompliance | 1.3.6.1.4.1.6486.801.1.2.1.24.1.2.2.1 | | | The compliance statement for device support of Stack Manager. |
| alcatelIND1StackMgrTrapObjects | 1.3.6.1.4.1.6486.801.1.2.1.24.1.3 | | | |
| ALA alaStackMgrTrapLinkNumber | 1.3.6.1.4.1.6486.801.1.2.1.24.1.3.1 | AlaStackMgrLinkNumber | accessible-for-notify | Holds the link number, when the stack is not in loop. |
| ALA alaStackMgrPrimary | 1.3.6.1.4.1.6486.801.1.2.1.24.1.3.2 | AlaStackMgrNINumber | accessible-for-notify | Holds the slot number of the stack element that plays the role of Primary. |
| ALA alaStackMgrSecondary | 1.3.6.1.4.1.6486.801.1.2.1.24.1.3.3 | AlaStackMgrNINumber | accessible-for-notify | Holds the slot number of the stack element that plays the role of Secondary. |
| alaStackMgrTraps | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4 | | | |
| NTF alaStackMgrDuplicateSlotTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.1 | | | The element specified by alaStackMgrSlotNINumber has the same slot number of
another element of the stack and it must relinquish its operational status
because it has a higher election key (up time, slot, mac).
The elements will be put in pass through mode. |
| NTF alaStackMgrNeighborChangeTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.2 | | | Indicates whether the stack is in loop or not.
In case of no loop, alaStackMgrSlotNINumber and alaStackMgrTrapLinkNumber
indicate where the Stack is broken |
| NTF alaStackMgrRoleChangeTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.3 | | | Role Change Trap. Indicates that a new primary or secondary is elected. |
| NTF alaStackMgrDuplicateRoleTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.4 | | | The element identified by alaStackMgrSlotNINumber detected the presence of
two elements with the same primary or secondary role as specified by
alaStackMgrChasRole on the stack. |
| NTF alaStackMgrClearedSlotTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.5 | | | The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because its operational slot was cleared with immediate effect. |
| NTF alaStackMgrOutOfSlotsTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.6 | | | One element of the stack will enter the pass through mode because there
are no slot numbers available to be assigned to this element. |
| NTF alaStackMgrOutOfTokensTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.7 | | | The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because there are no tokens available to be assigned to this element. |
| NTF alaStackMgrOutOfPassThruSlotsTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.8 | | | There are no pass through slots available to be assigned to an element
that is supposed to enter the pass through mode. |
| NTF alaStackMgrBadMixTrap | 1.3.6.1.4.1.6486.801.1.2.1.24.1.4.0.9 | | | The element identified by alaStackMgrSlotNINumber will enter the pass through
mode because it is not compatible with the existing stack. |