XF-RADIOLINK-PTP-MODEM-MIB

MIB Reference — IPNetwork Monitor

All MIBsXF-RADIOLINK-PTP-MODEM-MIB

Organization: Ericsson AB

Last Updated: 2012-05-29

Category: Ericsson Radio Link

Description:

Monitors Ericsson XF point-to-point radio link modem configuration, modulation status, and performance.

Imported Objects

From ENTITY-MIB

entPhysicalIndexOBJECT-TYPE

From IF-MIB

ifIndexOBJECT-TYPE

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

TEXTUAL-CONVENTION

From XF-RADIOLINK-PTP-TERMINAL-MIB

xfTermRowIndexOBJECT-TYPE

From XF-TOP-MIB

xfRadioLinkOBJECT-IDENTITY

What Is XF-RADIOLINK-PTP-MODEM-MIB?

XF-RADIOLINK-PTP-MODEM-MIB is an Ericsson AB proprietary MIB for point-to-point Radiolink microwave modems. Its modem table, keyed by index, records MMU (Modem Modulator Unit) alarm status, module-index-validity, ATPC (Automatic Transmit Power Control) capability, modulation/capacity capability, protection path, slot position, channel-mode capability, channel companion slot/index, interface capability, and RAU (Radio Access Unit) supply voltage, while a RAU-interface table records loopback enable/RX-loop state and alarms, a LINE/RS table records alarms, and a modem-capability table extends detection. As a configuration/status MIB it lets an administrator confirm ATPC/protection-path settings and watch modem/RAU alarm status on an Ericsson Radiolink point-to-point microwave link. It is deployed on Ericsson AB Radiolink point-to-point microwave modems. Engineers can download the XF-RADIOLINK-PTP-MODEM-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in XF-RADIOLINK-PTP-MODEM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • modem/RAU alarm status and ATPC/protection configuration

Supported Devices

  • Ericsson AB Radiolink point-to-point microwave modems

Monitoring Examples

An administrator checks xfMMUAlarmStatus and xfRAUIFAlarms to diagnose an active alarm condition on an Ericsson Radiolink point-to-point microwave modem.

OIDs
OID symbolicOID numericTypeAccessDescription
xfRadioLinkPtpModemMIB1.3.6.1.4.1.193.81.3.4.2This MIB defines objects for point-to-point Radiolink modems ().
xfRadioLinkPtpModemObjects1.3.6.1.4.1.193.81.3.4.2.1
xfModemTable1.3.6.1.4.1.193.81.3.4.2.1.1not-accessibleTable for Radiolink point-to-points modem managed objects. The tabled is indexed with entPhysicalIndex.
xfModemEntry1.3.6.1.4.1.193.81.3.4.2.1.1.1not-accessibleAn entry in the xfModemTable
MMU xfMMUAlarmStatus1.3.6.1.4.1.193.81.3.4.2.1.1.1.1MMUAlarmStatusread-onlyThis object shows the alarm status of the modem.
MMU xfMMUModIndexNotValid1.3.6.1.4.1.193.81.3.4.2.1.1.1.2MMUModIndexStatusread-onlyThis object shows if modulation index is valid. OBSOLETE.
MMU xfMMUAtpcCapability1.3.6.1.4.1.193.81.3.4.2.1.1.1.3MMUAtpcCapabilityread-onlyThis object shows the atpc capability.
MMU xfMMUModCapability1.3.6.1.4.1.193.81.3.4.2.1.1.1.4MMUModCapabilityread-onlyThis object shows the modulation capability.
MMU xfMMUCapacityCapability1.3.6.1.4.1.193.81.3.4.2.1.1.1.5MMUCapCapabilityread-onlyThis object shows the capacity capability.
INT xfMMUProtectionPath1.3.6.1.4.1.193.81.3.4.2.1.1.1.6INTEGERread-onlyThis object indicates what radio path the modem belongs to.
I32 xfMMUSlotPosition1.3.6.1.4.1.193.81.3.4.2.1.1.1.7Integer32read-onlyThe AMM slot position in which the MMU2 X is inserted in. 0 = Unknown, 1-20 = slot position.
BIT xfMMUChannelModeCapability1.3.6.1.4.1.193.81.3.4.2.1.1.1.8Bitsread-onlyChannel capability.
I32 xfMMUChannelCompanionSlot1.3.6.1.4.1.193.81.3.4.2.1.1.1.9Integer32read-writeSlot number of companion channel MMU (XPIC/CCDP). Default value: 0 Near end access: read-write Far end access: read-only (Traffic Node only)
I32 xfMMUChannelCompanionIndex1.3.6.1.4.1.193.81.3.4.2.1.1.1.10Integer32read-only0 if CCDP not selected entPhysicalIndex of companion channel MMU (XPIC/CCDP) according to xfMMUChannelCompanionSlot setting.
BIT xfMMUInterfaceCapability1.3.6.1.4.1.193.81.3.4.2.1.1.1.11Bitsread-onlyInterface capability for MMU.
INT xfMMURAUSupplyVoltage1.3.6.1.4.1.193.81.3.4.2.1.1.1.12INTEGERread-onlyThe radio nominal supply voltage. Values: other(1) p55V(2) default m48V(3) p24V(4)
xfRAUIFTable1.3.6.1.4.1.193.81.3.4.2.1.2not-accessibleTable for rau interface objects. The tabled is indexed with ifIndex.
xfRAUIFEntry1.3.6.1.4.1.193.81.3.4.2.1.2.1not-accessibleAn entry in the xfRAUIFTable
INT xfRAUIFLoopEnable1.3.6.1.4.1.193.81.3.4.2.1.2.1.1INTEGERread-writeThis object manage the IF loop. Default value: disable(3) Near end access: read-write Far end access: no access
INT xfRAUIFRxLoop1.3.6.1.4.1.193.81.3.4.2.1.2.1.2INTEGERread-writeThis object manage the Far end rx loop. Default value: disable(3)
BIT xfRAUIFAlarms1.3.6.1.4.1.193.81.3.4.2.1.2.1.3Bitsread-onlyThis object shows rau if related alarms.
BIT xfRAUIFStatus1.3.6.1.4.1.193.81.3.4.2.1.2.1.4Bitsread-onlyThis object shows test loop status.
xfLINERSTable1.3.6.1.4.1.193.81.3.4.2.1.3not-accessibleTraffic node extension of ifTable. The tabled is indexed with ifIndex.
xfLINERSEntry1.3.6.1.4.1.193.81.3.4.2.1.3.1not-accessibleAn entry in the xfLINERSTable
BIT xfLINERSAlarms1.3.6.1.4.1.193.81.3.4.2.1.3.1.1Bitsread-onlyThis object shows line rs related alarms.
xfModemCapabilityTable1.3.6.1.4.1.193.81.3.4.2.1.4not-accessibleTable for misc. modem capability information.
xfModemCapabilityEntry1.3.6.1.4.1.193.81.3.4.2.1.4.1not-accessibleAn entry in the xfModemCapabilityTable
MMU xfMMUChannelSpacing1.3.6.1.4.1.193.81.3.4.2.1.4.1.1MMUChannelSpacingCapabilityread-onlyChannel spacing. ETSI: 3.5, 7, 14, 28, 40, 56 MHz ANSI: 10, 20, 30, 40, 50 MHz
MOD xfMMUChannelModulation1.3.6.1.4.1.193.81.3.4.2.1.4.1.2ModemModulationread-onlyThis object shows the channel modulation. Values: cqpsk(2) CQPSK qam16(3) 16-QAM qam128(4) 128-QAM qam32(5) 32-QAM qam64(6) 64-QAM qam4(7) 4-QAM qam8(8) 8-QAM qam256(9) 256-QAM qam512(10) 512-QAM qam1024(11) 1024-QAM
I32 xfMMUMaxTribCapacity1.3.6.1.4.1.193.81.3.4.2.1.4.1.3Integer32read-onlyMax tributaries.
I32 xfMMUDCNCapacity1.3.6.1.4.1.193.81.3.4.2.1.4.1.4Integer32read-onlyDCN Hop Capacity.
I32 xfMMUMaxCapacity1.3.6.1.4.1.193.81.3.4.2.1.4.1.5Integer32read-onlyMax Capacity.
MMU xfMMUFrameFormatType1.3.6.1.4.1.193.81.3.4.2.1.4.1.6MMUFrameFormatTyperead-onlyFrame format type. Values: fftUnknown(0) fftStatic(1) fftAdMod(2) fftXpic(3) fftXpicAdmod(4) fftLegacy(5)
INT xfMMUFrameFormatRev1.3.6.1.4.1.193.81.3.4.2.1.4.1.7INTEGERread-onlyFrame format revision.
BIT xfMMUBerAlarmThresholdCapability1.3.6.1.4.1.193.81.3.4.2.1.4.1.8Bitsread-onlyList of the allowed BER thresholds.
xfRadioLinkPtpModemConformance1.3.6.1.4.1.193.81.3.4.2.2
xfRadioLinkPtpModemCompliances1.3.6.1.4.1.193.81.3.4.2.2.1
xfRadioLinkPtpModemFullCompliance1.3.6.1.4.1.193.81.3.4.2.2.1.1The compliance statement for SNMP entities which implement everything.
xfRadioLinkPtpModemGroups1.3.6.1.4.1.193.81.3.4.2.2.2
xfRadioLinkPtpModemCompleteGroup1.3.6.1.4.1.193.81.3.4.2.2.2.1A collection of all current objects in this MIB module.

RFC description

Manages point-to-point radio modem configurations and performance metrics for Ericsson Radiolink equipment.

Start monitoring Ericsson AB Radiolink point-to-point microwave modem (ATPC/protection-path/RAU-alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download XF-RADIOLINK-PTP-MODEM-MIB