| OID symbolic | OID numeric | Type | Access | Description |
| ubiEntityMIB | 1.3.6.1.4.1.7800.100.3 | | | The UBQS-ENTITY-MIB is used to monitor
and configure operational status of
Field Replaceable Units (FRUs) and other managable
physical entities of the system listed in the
Entity-MIB (RFC 2737) entPhysicalTable. |
| ubiEntityMIBObjects | 1.3.6.1.4.1.7800.100.3.1 | | | |
| ubiEntityNotificationEnables | 1.3.6.1.4.1.7800.100.3.1.1 | | | |
| T/F ubiFRUControlEnabled | 1.3.6.1.4.1.7800.100.3.1.1.1 | TruthValue | read-write | This variable indicates whether the system
produces the following notifications:
ubiEntityFRUInserted, ubiEntityFRURemoved.
A false value will prevent these notifications
from being generated. |
| T/F ubiEntSensorThresholdNotificationEnabled | 1.3.6.1.4.1.7800.100.3.1.1.2 | TruthValue | read-write | This variable indicates whether the system
produces the following notification:
ubiEntSensorThreshold.
A false value will prevent these notifications
from being generated. |
| ubiModuleTable | 1.3.6.1.4.1.7800.100.3.1.2 | | not-accessible | This table contains one row per module entity. |
| ubiModuleEntry | 1.3.6.1.4.1.7800.100.3.1.2.1 | | not-accessible | Information about a particular module entity. |
| INT ubiModuleId | 1.3.6.1.4.1.7800.100.3.1.2.1.1 | INTEGER | read-only | The unique module ID. |
| STR ubiModuleType | 1.3.6.1.4.1.7800.100.3.1.2.1.2 | DisplayString | read-only | The textual type of this module. |
| MOD ubiModuleOperStatus | 1.3.6.1.4.1.7800.100.3.1.2.1.3 | ModuleOperType | read-only | The operational state of this module. |
| TIM ubiModuleStatusLastChangeTime | 1.3.6.1.4.1.7800.100.3.1.2.1.4 | TimeStamp | read-only | The value of sysUpTime when ubiModuleOperStatus
is changed. |
| STR ubiModuleSerialNumber | 1.3.6.1.4.1.7800.100.3.1.2.1.5 | DisplayString | read-only | The serial number of this module. |
| I32 ubiModuleSlotNumber | 1.3.6.1.4.1.7800.100.3.1.2.1.6 | Integer32 | read-only | This value is determined by the number of slot
where the module is located. |
| I32 ubiModulePortNumber | 1.3.6.1.4.1.7800.100.3.1.2.1.7 | Integer32 | read-only | This value is determined by the number of port
where the module is located. |
| INT ubiModuleAction | 1.3.6.1.4.1.7800.100.3.1.2.1.8 | INTEGER | read-write | This object, when read, returns one of the
following results:
other(1): module permanently enabled
Setting this object to one of the acceptable values
gives the following results:
other(1): gives an error
reset(2): resets the module's control logic
Setting this object to any other values results in
an error. |
| ubiSlotTable | 1.3.6.1.4.1.7800.100.3.1.3 | | not-accessible | This table contains one row per slot entity. |
| ubiSlotEntry | 1.3.6.1.4.1.7800.100.3.1.3.1 | | not-accessible | Information about a particular slot entity. |
| INT ubiSlotModuleId | 1.3.6.1.4.1.7800.100.3.1.3.1.1 | INTEGER | read-only | The unique module ID. |
| INT ubiSlotId | 1.3.6.1.4.1.7800.100.3.1.3.1.2 | INTEGER | read-only | The unique slot ID. |
| STR ubiSlotType | 1.3.6.1.4.1.7800.100.3.1.3.1.3 | DisplayString | read-only | The textual type of this slot. |
| MOD ubiSlotOperStatus | 1.3.6.1.4.1.7800.100.3.1.3.1.4 | ModuleOperType | read-only | The status of this slot. |
| I32 ubiSlotPortNumber | 1.3.6.1.4.1.7800.100.3.1.3.1.5 | Integer32 | read-only | This value is determined by the number of port
where the slot is located. |
| STR ubiSlotSerialNumber | 1.3.6.1.4.1.7800.100.3.1.3.1.6 | DisplayString | read-write | The serial number of this slot. |
| ubiExtSlot | 1.3.6.1.4.1.7800.100.3.1.4 | | | |
| INT ubiIEEE1588SlotOperStatusEx | 1.3.6.1.4.1.7800.100.3.1.4.1 | INTEGER | read-only | The operational status of the slot for
IEEE 1588 specification. |
| INT ubiMngSlotOperStatus | 1.3.6.1.4.1.7800.100.3.1.4.2 | INTEGER | read-only | The operational status of the slot for
mng specification. |
| ubiTransceiver | 1.3.6.1.4.1.7800.100.3.1.5 | | | |
| ubiEntitySensorTable | 1.3.6.1.4.1.7800.100.3.1.5.1 | | not-accessible | This table contains objects which provide information
about the transceiver sensor of physical entity. |
| ubiEntitySensorEntry | 1.3.6.1.4.1.7800.100.3.1.5.1.1 | | not-accessible | An entry containing management information applicable
to the transceiver sensor of a particular physical entity. |
| UBI ubiEntSensorType | 1.3.6.1.4.1.7800.100.3.1.5.1.1.1 | UbiSensorDataType | read-only | This variable indicates the type of data reported
by the entSensorValue.
valid values are:
other(1): a measure other than those listed below
unknown(2): unknown measurement, or
arbitrary, relative numbers
voltsAC(3): electric potential
voltsDC(4): electric potential
amperes(5): electric current
celsius(6): temperature
dBm(7): dB relative to 1mW of power |
| UBI ubiEntSensorScale | 1.3.6.1.4.1.7800.100.3.1.5.1.1.2 | UbiSensorDataScale | read-only | This variable indicates the exponent to apply
to sensor values reported by entSensorValue. |
| UBI ubiEntSensorValue | 1.3.6.1.4.1.7800.100.3.1.5.1.1.3 | UbiSensorValue | read-only | This variable reports the most recent measurement seen
by the sensor. |
| INT ubiEntSensorEventStatus | 1.3.6.1.4.1.7800.100.3.1.5.1.1.4 | INTEGER | read-only | This variable indicates the present
current event status of the sensor. |
| TIM ubiEntSensorEventUpdateTime | 1.3.6.1.4.1.7800.100.3.1.5.1.1.5 | TimeStamp | read-only | The value of sysUpTime when the status of
entity sensor is changed. |
| UBI ubiEntSensorAlarmHighThreshold | 1.3.6.1.4.1.7800.100.3.1.5.1.1.6 | UbiSensorValue | read-write | This variable indicates the value of
the high alarm threshold. |
| UBI ubiEntSensorWarningHighThreshold | 1.3.6.1.4.1.7800.100.3.1.5.1.1.7 | UbiSensorValue | read-write | This variable indicates the value of
the high warning threshold. |
| UBI ubiEntSensorWarningLowThreshold | 1.3.6.1.4.1.7800.100.3.1.5.1.1.8 | UbiSensorValue | read-write | This variable indicates the value of
the low warning threshold. |
| UBI ubiEntSensorAlarmLowThreshold | 1.3.6.1.4.1.7800.100.3.1.5.1.1.9 | UbiSensorValue | read-write | This variable indicates the value of
the low alarm threshold. |
| STR ubiEntSensorName | 1.3.6.1.4.1.7800.100.3.1.5.1.1.10 | DisplayString | read-only | This variable indicates the name of
the sensor entity. |
| ubiTransceiverInfoTable | 1.3.6.1.4.1.7800.100.3.1.5.2 | | not-accessible | This table contains objects which provide information
about the transceiver of physical entity. |
| ubiTransceiverInfoEntry | 1.3.6.1.4.1.7800.100.3.1.5.2.1 | | not-accessible | An entry containing management information applicable
to the transceiver of a particular physical entity. |
| OID ubiTcIdentifier | 1.3.6.1.4.1.7800.100.3.1.5.2.1.1 | UbiTcIdentifier | read-only | This variable indicates the transceiver indentifier.
valid value are:
unknown(0),
other(1),
gbic(2),
module(3),
sfp(4),
xbi(5),
xenpak(6),
xfp(7),
xff(8),
xfpE(9),
xpak(10),
x2(11) |
| STR ubiTcVendorOUI | 1.3.6.1.4.1.7800.100.3.1.5.2.1.2 | DisplayString | read-only | This variable indicates a textual string containing
information about the IEEE company ID of transceiver vendor |
| STR ubiTcVendorName | 1.3.6.1.4.1.7800.100.3.1.5.2.1.3 | DisplayString | read-only | A textual string containing information about the
transceiver name. |
| STR ubiTcVendorPartNumber | 1.3.6.1.4.1.7800.100.3.1.5.2.1.4 | DisplayString | read-only | A textual string containing information about the
part number of the transceiver. |
| STR ubiTcVendorRevisionLevel | 1.3.6.1.4.1.7800.100.3.1.5.2.1.5 | DisplayString | read-only | A textual string containing information about the
revision level of the transceiver part number. |
| STR ubiTcVendorSerialNumber | 1.3.6.1.4.1.7800.100.3.1.5.2.1.6 | DisplayString | read-only | This variable indicates a textual string containing
information about the transceiver serial number. |
| STR ubiTcVendorManufacturingDate | 1.3.6.1.4.1.7800.100.3.1.5.2.1.7 | DisplayString | read-only | This variable indicates a manufacturing date
of transceiver |
| I32 ubiTcWaveLength | 1.3.6.1.4.1.7800.100.3.1.5.2.1.8 | Integer32 | read-only | This variable indicates a wave length
of transceiver. |
| UBI ubiTcConnector | 1.3.6.1.4.1.7800.100.3.1.5.2.1.9 | UbiTcConnectorType | read-only | This variable indicates a connector type
of transceiver. |
| I32 ubiTcLength | 1.3.6.1.4.1.7800.100.3.1.5.2.1.10 | Integer32 | read-only | This variable indicates a length
of transceiver. |
| T/F ubiTransceiverMonitoring | 1.3.6.1.4.1.7800.100.3.1.5.3 | TruthValue | read-write | This variable indicates whether the system produces
the log and notification for transceiver sensor. |
| ubiEntityMIBNotificationPrefix | 1.3.6.1.4.1.7800.100.3.2 | | | |
| ubiFruNotifications | 1.3.6.1.4.1.7800.100.3.2.0 | | | |
| NTF ubiFRUInserted | 1.3.6.1.4.1.7800.100.3.2.0.1 | | | The ubiEntityFRUInserted notification indicates that a FRU was
inserted. The varbind for this notification indicates the
entPhysicalIndex of the inserted FRU, and the entPhysicalIndex
of the FRU's container. |
| NTF ubiFRURemoved | 1.3.6.1.4.1.7800.100.3.2.0.2 | | | The ubiEntityFRURemoved notification indicates that a FRU was
removed. The varbind for this notification indicates the
entPhysicalIndex of the removed FRU, and the entPhysicalIndex
of the FRU's container. |
| ubiEntitySensorNotifications | 1.3.6.1.4.1.7800.100.3.2.1 | | | |
| NTF ubiEntSensorThreshold | 1.3.6.1.4.1.7800.100.3.2.1.1 | | | The ubiEntSensorThreshold notification indicates that
the status of transceiver sensor was changed. |
| ubiEntityMIBConformance | 1.3.6.1.4.1.7800.100.3.3 | | | |
| ubiEntityMIBCompliances | 1.3.6.1.4.1.7800.100.3.3.1 | | | |
| ubiEntityMIBCompliance | 1.3.6.1.4.1.7800.100.3.3.1.1 | | | An Entity-MIB implementation can implement this group to
provide FRU status and control. |
| ubiEntityMIBGroups | 1.3.6.1.4.1.7800.100.3.3.2 | | | |
| ubiEntityMIBModuleGroup | 1.3.6.1.4.1.7800.100.3.3.2.1 | | | The collection of objects which are used to get the
operational state and redundancy state of the modules |
| ubiEntitySlotGroup | 1.3.6.1.4.1.7800.100.3.3.2.2 | | | The collection of objects which are used to get the
operational state and redundancy state of the slot. |
| ubiEntityMIBNotificationGroup | 1.3.6.1.4.1.7800.100.3.3.2.3 | | | TThe collection of objects which are
used to send a notification. |
| ubiEntiryMIBIEEE1588SlotGroup | 1.3.6.1.4.1.7800.100.3.3.2.4 | | | The collection of objects which are used to get the
operational state of the slot for IEEE 1588. |
| ubiEntityMIBTransceiverGroup | 1.3.6.1.4.1.7800.100.3.3.2.5 | | | The collection of objects which are used to get the
information of transceiver. |