TP5000E :: tp5000eSync

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TP5000E › tp5000eSync

tp5000eSync

Module: TP5000E

OID (symbolic): TP5000E::tp5000eSync

OID (numeric): 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: This object is used to force system time and phase to synchronize to the selected reference (synchronize between IMC and IOC). This object is write-only, and the value must be 'now.'

What is tp5000eSync?

Setting tp5000eSync to the literal value 'now' forces the system to immediately synchronize its time and phase (IMC and IOC) to the currently selected reference; it is effectively write-only despite SNMP having no true write-only type.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3
snmpwalk -v2c -c public <target> TP5000E::tp5000eSync

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3.1
snmpget -v2c -c public <target> TP5000E::tp5000eSync.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3.1 s <value>

Start monitoring Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TP5000E::tp5000eSync OID value, configure state conditions and alerts, and monitor any Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9070symmetricomSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1symmNetworkManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2symmSnmpManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5symmCommonModelV1SYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5.7symmDeviceDependentSYMM-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9070.1.2.5.7.1tp5000eTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8tp5000eClockTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8.2tp5000eClockConfigTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3tp5000eSyncTP5000E