-- -- TP5000E.mib -- MIB generated by MG-SOFT Visual MIB Builder 2013 (64-bit) Version 9.0 Build 760 -- Friday, October 14, 2016 at 04:05:08 -- -- TP5000E.mib -- MIB generated by MG-SOFT Visual MIB Builder 2013 (64-bit) Version 9.0 Build 760 -- Wednesday, August 12, 2015 at 17:16:25 -- -- TP5000E.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Monday, August 22, 2011 at 10:48:15 -- -- TP5000E.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Friday, July 01, 2011 at 14:07:58 -- -- TP5000E.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Tuesday, March 29, 2011 at 13:01:56 -- -- TP5000E.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Tuesday, February 08, 2011 at 14:36:23 -- -- TP5000EXT.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Wednesday, February 02, 2011 at 10:14:22 -- -- TP5000EXT.my -- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209 -- Thursday, January 27, 2011 at 18:27:52 -- TP5000E DEFINITIONS ::= BEGIN IMPORTS entPhysicalIndex FROM ENTITY-MIB ifNumber, ifIndex FROM IF-MIB InetAddressIPv6 FROM INET-ADDRESS-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF snmpModules, IpAddress, Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC symmDeviceDependent, TP5000MODULEID, EnableValue, ONVALUETYPE, ACTIONONLY, YESVALUETYPE FROM SYMM-COMMON-SMI; -- 1.3.6.1.4.1.9070.1.2.5.7.1 -- Feb 01, 2011 at 00:00 GMT -- -- 1.3.6.1.4.1.9070.1.2.5.7.1 -- March 29, 2011 at 13:17 GMT -- March 01, 2011 at 10:24 GMT -- 1.3.6.1.4.1.9070.1.2.5.7.1 tp5000e MODULE-IDENTITY LAST-UPDATED "201803220437Z" -- March 22, 2018 at 04:37 GMT ORGANIZATION "Symmetricom" CONTACT-INFO "Symmetricom Technical Support 1-888-367-7966 toll free USA 1-408-428-7907 worldwide Support@symmetricom.com " DESCRIPTION "This MIB is the equipment-specific subset MIB for the TP5000e system. " REVISION "201803220437Z" -- March 22, 2018 at 04:37 GMT DESCRIPTION "Version 1.0" ::= { symmDeviceDependent 1 } -- -- Type definitions -- -- Type definitions -- TP5000LEDID ::= INTEGER { bta(1), btb(2), sys(3), alm(4), gpsOrGnss(5), mgmt(6), act(7), alarm(8), eth1(9), eth2(10), holdover(11), ref(12), pwra(13), pwrb(14), shelfPower(15), shelfBatA(16), shelfBatB(17), shelfAlarm(18), shelfMgmt(19), shelfRef(20) } TP5000LEDTYPE ::= INTEGER { off(0), on(1), red(2), redblink(3), green(4), greenblink(5), amber(6), amberblink(7) } ALARMLEVELTYPE ::= INTEGER { clear(0), critical(2), major(3), minor(4), event(5) } TP5000IOCPORTID ::= INTEGER { eth1(1), eth2(2), none(5) } TP5000IMAGEACTIVE ::= INTEGER { active(1), inactive(2) } TP5000INTRAIPSET ::= INTEGER { setA(0), setB(1), setC(2) } TP5000PACKETSERVICE ::= INTEGER { ptpGM(1), ptpProbe(2), ntpServer(3), ntpProbe(4) } TP5000SSMOPTION ::= INTEGER { option1(1), option2(2) } TP5000REFQUALIFICATION ::= INTEGER { disable(0), qualified(1), disqualified(2), selected(3) } TP5000REFTIMINGMODE ::= INTEGER { time(1), frequency(2) } TP5000REFSELECTMODE ::= INTEGER { manual(1), priority(2), ssm(3) } TP5000SERVOCTL ::= INTEGER { warmup(1), freerun(2), fasttrack(3), normaltrack(4), holdover(5), bridge(6), fail(7), offline(8), extHoldover(9), localFreerun(10), localHoldover(11) } TP5000TRANSIENT ::= INTEGER { stateEvent(0), transientEvent(1) } TP5000IOPORTID ::= INTEGER { port1(1), port2(2), port3(3), port4(4), none(5) } TP5000IOTYPE ::= INTEGER { input(1), output(2) } TP5000SSMVALUE ::= INTEGER (1..15) -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- -- Textual conventions -- DateAndTime ::= TEXTUAL-CONVENTION DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d" STATUS current DESCRIPTION "A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present." SYNTAX OCTET STRING (SIZE (8 | 11)) TLatAndLon ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a1d:1d:1d.1d" STATUS current DESCRIPTION "antenna latitude and longitude specification. field octets contents range ----- ------ -------- ----- 1 1 +/-180 deg '+' / '-' 2 2 degree 0..180 3 3 minute 0..59 4 4 second 0..59 5 5 second fraction 0..99 +/- dd:mm:ss.ss " SYNTAX OCTET STRING (SIZE (5)) TAntHeight ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a2d.1d" STATUS current DESCRIPTION "antenna height specification. field octets contents range ----- ------ -------- ----- 1 1 +/- '+' / '-' 2 2-3 meter 0..10000 3 4 meter fraction 0..99 +/- hh.hh " SYNTAX OCTET STRING (SIZE (4)) TLocalTimeOffset ::= TEXTUAL-CONVENTION DISPLAY-HINT "1a1d:1d" STATUS current DESCRIPTION "A local time offset specification. field octets contents range ----- ------ -------- ----- 1 1 direction from UTC '+' / '-' 2 2 hours from UTC* 0..13 3 3 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - The hours range is 0..13 For example, the -6 local time offset would be displayed as: -6:0 " SYNTAX OCTET STRING (SIZE (3)) TSsm ::= TEXTUAL-CONVENTION DISPLAY-HINT "x" STATUS current DESCRIPTION "The ssm hex code" SYNTAX INTEGER (0..255) -- -- Node definitions -- -- Node definitions -- -- Node definitions -- -- TP5000 evolution system status tree -- 1.3.6.1.4.1.9070.1.2.5.7.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1 tp5000eSystemStatus OBJECT IDENTIFIER ::= { tp5000e 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1 tp5000eLedTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eLedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table of the front panel LED status for a specified module. The module can be IMC, IOC1, IOC2, or an expansion shelf." ::= { tp5000eSystemStatus 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1 tp5000eLedEntry OBJECT-TYPE SYNTAX Tp5000eLedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the LED table contains status for one of the LEDs in a specified module. This table has a double index: entPhysicalIndex and tp5000LEDID." INDEX { entPhysicalIndex, tp5000eLedID } ::= { tp5000eLedTable 1 } Tp5000eLedEntry ::= SEQUENCE { tp5000eLedID TP5000LEDID, tp5000eLedStatus TP5000LEDTYPE } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.1 tp5000eLedID OBJECT-TYPE SYNTAX TP5000LEDID MAX-ACCESS read-only STATUS current DESCRIPTION "LED ID are LED names on the module front panel. Currently, the TP5000E system has 14 unique LED names. Some LED names (ALM and MGMT) are used on different module types. IMC LEDs: 1) BT A (battery terminal A-bus power) 2) BT B (battery terminal B-bus power) 3) SYS (system health) 4) ALM (IMC alarm) 5) GNSS/GPS (GNSS/GPS status) 6) MGMT (Ethernet management port) IOC LEDs: 7) ACT (active IOC) 8) Alarm (IOC alarm) 9) ETH1 (Ethernet port 1) 10) ETH2 (Ethernet port 2) 11) Holdover (IOC oscillator status) Expansion shelf LEDs: 13) PWR A (A-bus power) 14) PWR B (B-bus power) 4) ALM (expansion shelf alarm) 6) MGMT (Ethernet management port) 12) REF (reference tracking status)" ::= { tp5000eLedEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.1.1.2 tp5000eLedStatus OBJECT-TYPE SYNTAX TP5000LEDTYPE MAX-ACCESS read-only STATUS current DESCRIPTION "LED status can be one of the following: Off(0), On(1), Red(2), Redblink(3), Green(4), Greenblink(5), Amber(6), Amberblink(7)" ::= { tp5000eLedEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2 tp5000eHWStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eHWStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of hardware status for a specified module (IMC, IOC1, IOC2, or an expansion shelf). It includes power supply voltages and other status information for the module hardware." ::= { tp5000eSystemStatus 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1 tp5000eHWStatusEntry OBJECT-TYPE SYNTAX Tp5000eHWStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of hardware status table. The table index is entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eHWStatusIndex } ::= { tp5000eHWStatusTable 1 } Tp5000eHWStatusEntry ::= SEQUENCE { tp5000eHWStatusIndex Integer32, tp5000eHWStatusInfo DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.1 tp5000eHWStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the TP5000E hardware status table." ::= { tp5000eHWStatusEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.2.1.2 tp5000eHWStatusInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "For each module, the hardware status information is DisplayString type, and has a list of hardware status (power supply voltages, etc.). Example for IMC: -48V-A : ok -48V-B : ok +1.2V : 1.211V +1.8V : 1.843V +2.5V : 2.526V +5.5V : 5.490V VCXO : 2.526V GPS Power : 5.464V GPS Current : 24mA GPS Antenna : ok FPGA : ok Example for an IOC: +1.8V : 1.805V 10M EFC : 1.116V 20M EFC : 0.872V 25M EFC : 1.155V 24.5M EFC : 1.155V 24.7M EFC : 1.253V OSC Current : 173mA FPGA VCCint : 1.005V FPGA VCCaux : 2.499V FPGA Temp : 60C FPGA Temp High : 61C FPGA Temp Low : 54C Example for an Ethernet expansion shelf: +1.8V : 1.805V 12V : 12.116V 2.5V : 2.572V 1.2V : 1.17V 0.9V : 1.0V 1.0V : 1.1V 5V : 5.01V 1.1A: 1.5A: 2.5A: 1.1B: 1.5B: 2.5B: Temperature : 54C Example for an E1/TOD expansion shelf: +1.8V : 1.805V 5 V : 5.016V 2.5 V : 2.520V 1.2 V : 1.1805V TIM2.5 V : 2.505V 1.0V : 1.053V TIM1.2V : 1.990V " ::= { tp5000eHWStatusEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3 tp5000eModUpTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eModUpTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Module up time for a specified module (IMC, IOC1, IOC2, or an expansion shelf)." ::= { tp5000eSystemStatus 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1 tp5000eModUpTimeEntry OBJECT-TYPE SYNTAX Tp5000eModUpTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the module up time table. The table index is entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eModUpTimeIndex } ::= { tp5000eModUpTimeTable 1 } Tp5000eModUpTimeEntry ::= SEQUENCE { tp5000eModUpTimeIndex Integer32, tp5000eModuleUpTime DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.1 tp5000eModUpTimeIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the module up time table." ::= { tp5000eModUpTimeEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.3.1.2 tp5000eModuleUpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module up time status for the module is a DisplayString type. Example for IMC: IMC uptime: 7 days 2 hrs 18 mins " ::= { tp5000eModUpTimeEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4 tp5000eModWarmUpTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eModWarmUpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of warm-up status for a specified module (IMC, IOC1, IOC2, or an expansion shelf)." ::= { tp5000eSystemStatus 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1 tp5000eModWarmUpEntry OBJECT-TYPE SYNTAX Tp5000eModWarmUpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the module warm-up status table. The table index is entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eModWarmUpIndex } ::= { tp5000eModWarmUpTable 1 } Tp5000eModWarmUpEntry ::= SEQUENCE { tp5000eModWarmUpIndex Integer32, tp5000eModWarmUpStatus DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.1 tp5000eModWarmUpIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the module warm-up status table." ::= { tp5000eModWarmUpEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.4.1.2 tp5000eModWarmUpStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module warm-up status for the module is a DisplayString type. Example for an IOC: IOC1 warm-up status: complete (total 1651 secs) " ::= { tp5000eModWarmUpEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.10 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5 tp5000eModStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eModStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of operating status for a specified module in the system (IMC, IOC1, IOC2, or an expansion shelf)." ::= { tp5000eSystemStatus 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.10.1 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9.1 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1 tp5000eModStatusEntry OBJECT-TYPE SYNTAX Tp5000eModStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the module operating status table. The table index is entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eModStatusIndex } ::= { tp5000eModStatusTable 1 } Tp5000eModStatusEntry ::= SEQUENCE { tp5000eModStatusIndex Integer32, tp5000eModStatusInfo DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.1 tp5000eModStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the module general status table." ::= { tp5000eModStatusEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.10.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.2.1.9.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.1.5.1.2 tp5000eModStatusInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A list of operating status parameters for the module. Example for main shelf status information: System name: TP5000 IMC time: 2010-03-08 20:33:30 IMC uptime: 7 days 2 hrs 18 mins IOC1 warmup status: complete (total 1651 secs) IOC1 state: active IOC1 uptime: 7 days 2 hrs 18 mins IOC2 warmup status: n/a IOC2 state: card not present IOC2 uptime: card not present Reference mode: time Current reference input: GPS Phase offset: 0 ns Clock status: normal track PTP mode eth1: multicast grandmaster PTP mode eth2: multicast grandmaster Active alarms: 1 Exp connections: 1,3,6,9 Example for an Ethernet expansion shelf status information: Expansion shelf: PTP-SyncE Shelf time: 2010-03-08 20:33:30 Shelf uptime: 7 days 2 hrs 18 mins Phase Offset: 0 ns Main Clock status: normal track Shelf clock status: normal track Combined Clock status: normal track PTP mode: multicast grandmaster SyncE output PQL: 2 Example of an E1/TOD expansion shelf status information: Expansion shelf: E1-TOD shelf time : 2010-03-08 20:33:30 shelf uptime : 7 days 2 hrs 18 mins Phase offset : 0 ns Main clock status : normal track Shelf clock status: normal track Combined Clock status: normal track E1 output PQL: 2 " ::= { tp5000eModStatusEntry 2 } -- TP5000 evolution alarm and event tree -- 1.3.6.1.4.1.9070.1.2.5.7.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2 tp5000eAlarmAndEvent OBJECT IDENTIFIER ::= { tp5000e 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1 tp5000eActAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eActAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of alarms that are still active in the TP5000E system." ::= { tp5000eAlarmAndEvent 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1 tp5000eActAlarmEntry OBJECT-TYPE SYNTAX Tp5000eActAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry for one active alarm in the active alarm table. The table index is the local index." INDEX { tp5000eActAlarmIndex } ::= { tp5000eActAlarmTable 1 } Tp5000eActAlarmEntry ::= SEQUENCE { tp5000eActAlarmIndex INTEGER, tp5000eActAlarmModID TP5000MODULEID, tp5000eActAlarmID Unsigned32, tp5000eActAlarmInternalIndex Unsigned32, tp5000eActAlarmDateTime DisplayString, tp5000eActAlarmSeverity ALARMLEVELTYPE, tp5000eActAlarmDesc DisplayString } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.1 tp5000eActAlarmIndex OBJECT-TYPE SYNTAX INTEGER (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The access (local) index of the active alarm table. The range of the table index is 1 to 500." ::= { tp5000eActAlarmEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.2 tp5000eActAlarmModID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the hardware module that generated this active alarm. In TP5000E system, the module name can be one of the following: SYS, IMC, IOC1, IOC2, IO, Exp0, Exp1,... Exp9. The module ID is only used to show the module name of a physical entity, but it is never used as an index. Indexing is done using entPhysicalIndex. " ::= { tp5000eActAlarmEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.3 tp5000eActAlarmID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm ID uniquely identifies an alarm type. All alarm IDs are listed and described in the User Guide. " ::= { tp5000eActAlarmEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.4 tp5000eActAlarmInternalIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "See alarm second index in User Guide. " ::= { tp5000eActAlarmEntry 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.5 tp5000eActAlarmDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp for this active alarm. It is the time when the alarm was reported. " ::= { tp5000eActAlarmEntry 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.6 tp5000eActAlarmSeverity OBJECT-TYPE SYNTAX ALARMLEVELTYPE MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm severity level can be one of the following: -critical(2), critical condition -major(3), error condition -minor(4), warning condition -event(5), normal but significant condition " ::= { tp5000eActAlarmEntry 6 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.1.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7 tp5000eActAlarmDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A description for the alarm. For a complete description of all alarms, please see the User Guide. A portion of the alarm and event table is shown below: ID Level State Delay transient Descriptions --------------------------------------------------- 0 critical enable 0 no Communication to peer card failed 1 minor enable 0 no GNSS receiver communications failed 2 minor enable 0 no GNSS receiver not tracking satellite 3 major enable 0 no TOD source invalid 4 event enable 0 yes TOD has been set by TOD source 5 event enable 0 yes System log time has been updated " ::= { tp5000eActAlarmEntry 7 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2 tp5000eActEventTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eActEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of events that are still active in the TP5000E system." ::= { tp5000eAlarmAndEvent 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1 tp5000eActEventEntry OBJECT-TYPE SYNTAX Tp5000eActEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry for one active event in the active event table. The table index is the local index." INDEX { tp5000eActEventIndex } ::= { tp5000eActEventTable 1 } Tp5000eActEventEntry ::= SEQUENCE { tp5000eActEventIndex INTEGER, tp5000eActEventModID TP5000MODULEID, tp5000eActEventID Unsigned32, tp5000eActEventInternlIndex Unsigned32, tp5000eActEventDateTime DisplayString, tp5000eActEventDesc DisplayString } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.1 tp5000eActEventIndex OBJECT-TYPE SYNTAX INTEGER (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The access (local) index of the active event table. The range of the table index is 1 to 500." ::= { tp5000eActEventEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.2 tp5000eActEventModID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the hardware module that reported the event. Module ID can be one of the following: SYS, IMC, IOC1, IOC2, or Exp0, Exp1,... Exp9. The module ID is only used to show the module name of a physical entity, but it is never used as an index. Indexing is done using entPhysicalIndex. " ::= { tp5000eActEventEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.3 tp5000eActEventID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The event ID uniquely identifies an event type. All event IDs are listed and described in the User Guide. " ::= { tp5000eActEventEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.4 tp5000eActEventInternlIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "See alarm second index in User Guide. " ::= { tp5000eActEventEntry 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.5 tp5000eActEventDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time stamp for this active event. It is the time when the event was reported. " ::= { tp5000eActEventEntry 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.2.1.6 tp5000eActEventDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A description for the event. For a complete description of all events, please see the User Guide." ::= { tp5000eActEventEntry 6 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3 tp5000eAlarmConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eAlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The alarm configuration table. Each alarm is defined by five alarm configuration parameters: alarm id, alarm severity level, delay time, enable state, and a description." ::= { tp5000eAlarmAndEvent 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1 tp5000eAlarmConfigEntry OBJECT-TYPE SYNTAX Tp5000eAlarmConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries of the alarm configuration table. Table index is a local index." INDEX { tp5000eAlarmConfigIndex } ::= { tp5000eAlarmConfigTable 1 } Tp5000eAlarmConfigEntry ::= SEQUENCE { tp5000eAlarmConfigIndex INTEGER, tp5000eAlarmConfigAID Unsigned32, tp5000eAlarmLevelSetting ALARMLEVELTYPE, tp5000eAlarmSettingDelay Integer32, tp5000eEnableAlarmState EnableValue, tp5000eAlarmConfigDesc DisplayString } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.1 tp5000eAlarmConfigIndex OBJECT-TYPE SYNTAX INTEGER (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the alarm configuration table. The range of the table index is 1 to 500." ::= { tp5000eAlarmConfigEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.2 tp5000eAlarmConfigAID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This value is the Alarm ID. The alarm definition for each ID is defined in the User Guide. " ::= { tp5000eAlarmConfigEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.3 tp5000eAlarmLevelSetting OBJECT-TYPE SYNTAX ALARMLEVELTYPE MAX-ACCESS read-write STATUS current DESCRIPTION "The alarm severity level can be one of the following: 2 Critical: critical condition 3 Major: error condition 4 Minor: warning condition 5 Event: normal but significant condition " ::= { tp5000eAlarmConfigEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.4 tp5000eAlarmSettingDelay OBJECT-TYPE SYNTAX Integer32 UNITS "second" MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm delay in seconds. The alarm is not reported if the alarm condition disappears before this delay time is up. The purpose of the alarm delay is to prevent reporting intermittent conditions. The range of the alarm delay is 0 to 84,600 seconds. Default value is 0." DEFVAL { 0 } ::= { tp5000eAlarmConfigEntry 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.5 tp5000eEnableAlarmState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm state control flag. The flag can be Enable (1) or Disable (2). The default value is Enable. If an alarm is disabled, the system will never report conditions associated with this alarm." DEFVAL { 2 } ::= { tp5000eAlarmConfigEntry 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.3.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.3.1.6 tp5000eAlarmConfigDesc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm description (from hardcoded alarm definition table)." ::= { tp5000eAlarmConfigEntry 6 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.4 tp5000eNumofStandingAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of currently active alarms in the TP5000E system, including those generated by the expansion shelves." ::= { tp5000eAlarmAndEvent 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.2.5 tp5000eMessageGenerate OBJECT-TYPE SYNTAX ONVALUETYPE MAX-ACCESS read-write STATUS current DESCRIPTION "This flag is used to generate all TP5000E alarm and event messages with this one action. The messages are sent to the alarm and event logs. This feature is used for testing purposes. For a message that specifies a port, only one message is generated instead of generating a message for each possible port. This object is actually write-only, but SNMP does not have write-only. " ::= { tp5000eAlarmAndEvent 5 } -- TP5000 evolution global configuration tree. -- 1.3.6.1.4.1.9070.1.2.5.7.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3 tp5000eGlobalConfig OBJECT IDENTIFIER ::= { tp5000e 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1 tp5000eLogFileConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eLogFileConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The log file table is used to configure the sizes of various log files. There are four log files: alarm log, event log, command log, and security log." ::= { tp5000eGlobalConfig 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1 tp5000eLogFileConfigEntry OBJECT-TYPE SYNTAX Tp5000eLogFileConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the log file configuration table. Table index is the local index." INDEX { tp5000eLogFileConfigIndex } ::= { tp5000eLogFileConfigTable 1 } Tp5000eLogFileConfigEntry ::= SEQUENCE { tp5000eLogFileConfigIndex Integer32, tp5000eLogFileTypeName DisplayString, tp5000eLogFileBufferSize Unsigned32 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.1 tp5000eLogFileConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "The local index of the log file configuration table." ::= { tp5000eLogFileConfigEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.2 tp5000eLogFileTypeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The log file name can be one of the following: Alarm, Event, Command, or Security. All alarm messages go into the alarm log. All event messages go into the event log. All user entered commands are recorded in the command log, except those commands related to user login and logout. All user login and logout commands are stored in the security log. " ::= { tp5000eLogFileConfigEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.1.1.3 tp5000eLogFileBufferSize OBJECT-TYPE SYNTAX Unsigned32 UNITS "Kbyte" MAX-ACCESS read-write STATUS current DESCRIPTION "The size for the specified log file. Log file size is specified in unit of Kbytes. The default and the maximum size is 100 KB per log." DEFVAL { 100 } ::= { tp5000eLogFileConfigEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2 tp5000eRemoteSyslogTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eRemoteSyslogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote syslog file control table. It is used to configure a remote syslog server to receive log messages from TP5000K system. Only one remote syslog server is supported at this time." ::= { tp5000eGlobalConfig 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1 tp5000eRemoteSyslogEntry OBJECT-TYPE SYNTAX Tp5000eRemoteSyslogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the remote syslog file control table." INDEX { tp5000eRemoteSyslogIndex } ::= { tp5000eRemoteSyslogTable 1 } Tp5000eRemoteSyslogEntry ::= SEQUENCE { tp5000eRemoteSyslogIndex Integer32, tp5000eRemoteSyslogState EnableValue, tp5000eRemoteSyslogAddr IpAddress } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.1 tp5000eRemoteSyslogIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "The local index of the remote syslog file control table. At this time only the index value of 1 is supported." ::= { tp5000eRemoteSyslogEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.2 tp5000eRemoteSyslogState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "The remote syslog state control. The setting can be either Enable (1) or Disable (2). Once this is set to Enable, all TP5000E log messages (intended for any of the four built-in logs) will be sent to the remote syslog server." DEFVAL { 2 } ::= { tp5000eRemoteSyslogEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.2.1.3 tp5000eRemoteSyslogAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the remote syslog machine. The format is xxx.xxx.xxx.xxx. It suports only IPv4 format. 0.0.0.0 denotes remote-syslog address is IPv6" ::= { tp5000eRemoteSyslogEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3 tp5000eRedundTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eRedundEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The port redundancy table for IOC modules. Currently the system is hardcoded for card redundancy. The only redundancy selection is whether to enable port redundancy within a module (port bonding). " ::= { tp5000eGlobalConfig 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1 tp5000eRedundEntry OBJECT-TYPE SYNTAX Tp5000eRedundEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the IOC port redundancy table. Table index is module index" INDEX { ifIndex, tp5000eRedundModuleID } ::= { tp5000eRedundTable 1 } Tp5000eRedundEntry ::= SEQUENCE { tp5000eRedundModuleID TP5000MODULEID, tp5000eRedundModState EnableValue, tp5000eRedundActivePort TP5000IOCPORTID } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.1 tp5000eRedundModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "The module ID can be either IOC1 or IOC2. The system is currently hardcoded for card redundancy (if two IOC cards are present, they are always configured as a redundancy pair, with one active and one on standby). Whichever module ID is used to access this table, the configuration will apply to both IOC cards. In the future when the two IOC cards can be independent, configuration will only apply to the current IOC module. " ::= { tp5000eRedundEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.2 tp5000eRedundModState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Port redundancy state can be either Enable (1) or Disable (2). When it is Enable, the two Ethernet ports on the specified IOC module will form a bonded pair. When two ports are bonded, they share the same IP address, but only one port is active; the other port is in standby mode." ::= { tp5000eRedundEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.3.1.3 tp5000eRedundActivePort OBJECT-TYPE SYNTAX TP5000IOCPORTID MAX-ACCESS read-write STATUS current DESCRIPTION "The port ID of the active port on an IOC module. The active port ID is either Eth1 (1) or Eth2 (2). This object can be used to set the desired port to be the active port; the other port automatically becomes the standby port." ::= { tp5000eRedundEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4 tp5000eImageTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eImageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Firmware image information for the selected module (IMC, IOC1, IOC2, or an expansion shelf). In TP5000E, each module can store two firmware images. The image that is selected as the active image will be used when the module is booted up next time. Two images are used in upgrading or downgrading. Image downloading is done through CLI only. " ::= { tp5000eGlobalConfig 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1 tp5000eImageEntry OBJECT-TYPE SYNTAX Tp5000eImageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of the firmware image table. Each entry contains objects of each module image information. The image table index is the entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eImageIndex } ::= { tp5000eImageTable 1 } Tp5000eImageEntry ::= SEQUENCE { tp5000eImageIndex Integer32, tp5000eImageNextBoot YESVALUETYPE, tp5000eImageID INTEGER, tp5000eImageCurrState TP5000IMAGEACTIVE, tp5000eImageInfoMsg DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.1 tp5000eImageIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the firmware image table." ::= { tp5000eImageEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.2 tp5000eImageNextBoot OBJECT-TYPE SYNTAX YESVALUETYPE MAX-ACCESS read-write STATUS current DESCRIPTION "This field indicates whether the board will be booted from this firmware image next time. Values can be either 'yes' or 'no.' Only one of the images can be selected for next boot. The field for the other image is automatically updated accordingly. " ::= { tp5000eImageEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.3 tp5000eImageID OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "For each module, there are up to two images. The range of image ID is 1 and 2." ::= { tp5000eImageEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.4 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.4 tp5000eImageCurrState OBJECT-TYPE SYNTAX TP5000IMAGEACTIVE MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of whether an image active or not. The value is either active (1) or inactive (2). " ::= { tp5000eImageEntry 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.5 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.4.1.5 tp5000eImageInfoMsg OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The information message for an image. " ::= { tp5000eImageEntry 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.5 tp5000eRebootTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eRebootEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The action to reboot a specified module (IMC, IOC1, IOC2, or an expansion shelf)." ::= { tp5000eGlobalConfig 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.7.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1 tp5000eRebootEntry OBJECT-TYPE SYNTAX Tp5000eRebootEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains objects of the module reboot information. The table index is entPhysicalIndex. Depending on the entPhysicalIndex, reboot can apply to the whole system (stack), a chassis, or a module. " INDEX { entPhysicalIndex, tp5000eRebootIndex } ::= { tp5000eRebootTable 1 } Tp5000eRebootEntry ::= SEQUENCE { tp5000eRebootIndex Integer32, tp5000eRebootAction ACTIONONLY } -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1.1 tp5000eRebootIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the module reboot table." ::= { tp5000eRebootEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.7.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.5.1.2 tp5000eRebootAction OBJECT-TYPE SYNTAX ACTIONONLY MAX-ACCESS read-write STATUS current DESCRIPTION "The action to reboot the module. Value is either Apply (1) or Nonapply (2). The active firmware image is used when the module is rebooted. Use tp5000eImageTable to select the active image. " ::= { tp5000eRebootEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.2 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6 tp5000eAuthRADIUSTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eAuthRADIUSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains IP addresses and access keys for the Radius authentication server. Radius enable state is set in tp5000eRadiusState outside of this table. " ::= { tp5000eGlobalConfig 6 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1 tp5000eAuthRADIUSEntry OBJECT-TYPE SYNTAX Tp5000eAuthRADIUSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the RADIUS table. " INDEX { tp5000eAuthRADIUSIndex } ::= { tp5000eAuthRADIUSTable 1 } Tp5000eAuthRADIUSEntry ::= SEQUENCE { tp5000eAuthRADIUSIndex INTEGER, tp5000eServerRADIUSIPAddress IpAddress, tp5000eAuthRADIUSKey DisplayString } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.2.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.1 tp5000eAuthRADIUSIndex OBJECT-TYPE SYNTAX INTEGER (1) MAX-ACCESS read-only STATUS current DESCRIPTION "A local index to the RADIUS table. Currently the system only supports RADIUS index value of 1. " ::= { tp5000eAuthRADIUSEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.2 tp5000eServerRADIUSIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The RADIUS server's IP address. Format for IPv4 address is xxx.xxx.xxx.xxx. An IP address cannot be set up if authRADIUS key value is none. " ::= { tp5000eAuthRADIUSEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.6.1.3 tp5000eAuthRADIUSKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication key for RADIUS server access." ::= { tp5000eAuthRADIUSEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.7 tp5000eAssetNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User assigned inventory asset number for the system." DEFVAL { "" } ::= { tp5000eGlobalConfig 7 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.4.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.4.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.4.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.8 tp5000eIntraCommIPSet OBJECT-TYPE SYNTAX TP5000INTRAIPSET MAX-ACCESS read-write STATUS current DESCRIPTION "Intra-communication IP set between IMC, IOCs and Expansion shelves. Value can be class A (1), B (2), C (3). Their ranges are: A: IP address range 10.0.250.8 to 10.0.250.47 B: IP address range 172.16.250.8 to 172.16.250.47, C: IP address range 192.168.250.8 to 192.168.250.47 The selected address set cannot be used for external Ethernet ports in this TP5000 system. Therefore, choose a set that does not conflict with the external network configuration. After the value is changed, IMC and IOC or expansion shelves will establish a new connection in 1 to 2 minutes." ::= { tp5000eGlobalConfig 8 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.9 tp5000eRadiusState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "The RADIUS state can be either Enable (1) or Disable (2). Use tp5000eAuthRadiusTable to configure access to the Radius server. " ::= { tp5000eGlobalConfig 9 } -- 1.3.6.1.4.1.9070.1.2.4.6.4.4.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.3.10 tp5000eLastConfig OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Last Config Update. " ::= { tp5000eGlobalConfig 10 } -- TP5000 evolution global service tree -- 1.3.6.1.4.1.9070.1.2.5.7.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4 tp5000eGlobalService OBJECT IDENTIFIER ::= { tp5000e 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1 tp5000ePacketServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000ePacketServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines packet service for the specified Ethernet interface on the IOC (main shelf). Currently, this table only applies to the main shelf IOC ports (Eth1 and Eth2); the Ethernet expansion shelves are currently fixed to provide 'PTP grandmaster over Ethernet.' " ::= { tp5000eGlobalService 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1 tp5000ePacketServiceEntry OBJECT-TYPE SYNTAX Tp5000ePacketServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the packet service table. Table index is ifIndex (index for interfaces and ports). The system is currently hardcoded for card redundancy (if two IOC cards are present, they are always configured as a redundancy pair, with one active and one on standby). Regardless of which IOC card ifIndex is used, the configuration will apply to both IOC cards. In the future when the two IOC cards can be independent, configuration will only apply to the IOC module with the current ifIndex. " INDEX { ifIndex, tp5000ePacketServiceIndex } ::= { tp5000ePacketServiceTable 1 } Tp5000ePacketServiceEntry ::= SEQUENCE { tp5000ePacketServiceIndex Integer32, tp5000ePacketServiceMode TP5000PACKETSERVICE } -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.1 tp5000ePacketServiceIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the packet service selection table." ::= { tp5000ePacketServiceEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.5.6.4.1.3 -- 1.3.6.1.4.1.9070.1.2.4.7.1.5.1.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.5.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.1.1.2 tp5000ePacketServiceMode OBJECT-TYPE SYNTAX TP5000PACKETSERVICE MAX-ACCESS read-write STATUS current DESCRIPTION "The packet service for this port. Value can be PTP Grandmaster (1), PTP probe (2), NTP server (3), or NTP probe (4). Note that packet service selection is done for each port, and the two Ethernet ports on the IOC can have different services. " ::= { tp5000ePacketServiceEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2 tp5000eSSMOptionTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eSSMOptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the table for selecting SSM network option for a specified shelf (IOC or Expansion shelf). Main shelf and expansion shelves can each have its own selection of SSM network options." ::= { tp5000eGlobalService 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1 tp5000eSSMOptionEntry OBJECT-TYPE SYNTAX Tp5000eSSMOptionEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the SSM option table. Table index is entPhysicalIndex." INDEX { entPhysicalIndex, tp5000eSSMOptionIndex } ::= { tp5000eSSMOptionTable 1 } Tp5000eSSMOptionEntry ::= SEQUENCE { tp5000eSSMOptionIndex Integer32, tp5000eSSMOption TP5000SSMOPTION } -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.1 tp5000eSSMOptionIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the SSM option selection table." ::= { tp5000eSSMOptionEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2.1.2 tp5000eSSMOption OBJECT-TYPE SYNTAX TP5000SSMOPTION MAX-ACCESS read-write STATUS current DESCRIPTION "Network option for SSM can be Option 1 (1) or Option 2 (2). Option 1 is for E1 based network. Option 2 is for DS1 based network. ITU-T G.781 and G.8265.1 specifies different SSM (QL) values for Option 1 and Option 2 networks." ::= { tp5000eSSMOptionEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.8.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.8.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.3 tp5000ePTPClientDataTableLock OBJECT-TYPE SYNTAX INTEGER { unlocked(0), locked(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The ptpClientDataTableLock will control the internal semaphore to lock or unlock the ptpClientDataTable. The table must be locked before it can be read. When the ptpClientDataTable is locked, the data in the table will not change. The ptpClientDataTableLock can be set up to be locked or to be unlocked. When the locked signal is issued, the internal semaphore will be increased and start to lock the ptpClientDataTable. When the unlocked signal is issued, the internal semaphore will be decreased. When the semaphore reaches zero (0), the ptpClientDataTable will be unlocked. " ::= { tp5000eGlobalService 3 } -- -- 1.3.6.1.4.1.9070.1.2.5.7.1.4.4 tp5000ePacketServiceExtendedMode OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), notavailable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Fixed configuration. IOC1-1: PTP-GM IOC1-2: NTP-Server" ::= { tp5000eGlobalService 4 } -- -- The PTP client management tree. Now only support TP500, TP1500 and Symmetricom soft-client. -- -- -- 1.3.6.1.4.1.9070.1.2.5.7.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.5 tp5000ePTPClientMgmt OBJECT IDENTIFIER ::= { tp5000e 5 } -- TP5000 evolution reference status tree. -- 1.3.6.1.4.1.9070.1.2.5.7.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6 tp5000eReferenceStatus OBJECT IDENTIFIER ::= { tp5000e 6 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1 tp5000eInputPQLTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eInputPQLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status table for a specified reference input. PQL (priority quality level) is reference quality used internally by the TP5000E system. Input SSM and other reference quality indicators are first mapped to PQL, and further processing is carried out using PQL. " ::= { tp5000eReferenceStatus 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1 tp5000eInputPQLEntry OBJECT-TYPE SYNTAX Tp5000eInputPQLEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the reference input status table. Index of the table is ifIndex." INDEX { ifIndex, tp5000eInputRefName } ::= { tp5000eInputPQLTable 1 } Tp5000eInputPQLEntry ::= SEQUENCE { tp5000eInputRefName DisplayString, tp5000eInputRefActualPQL Integer32, tp5000eInputRefQualified TP5000REFQUALIFICATION } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.1 tp5000eInputRefName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the reference. Currently supported references are GNSS, GPS, 1PPS+TOD1, 1PPS+TOD2, Span input 1, and Span input 2." ::= { tp5000eInputPQLEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.2 tp5000eInputRefActualPQL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This PQL value either corresponds to the actual SSM value in the reference (when SSM is available) or the default PQL value for the reference. " ::= { tp5000eInputPQLEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.9 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.1.1.3 tp5000eInputRefQualified OBJECT-TYPE SYNTAX TP5000REFQUALIFICATION MAX-ACCESS read-only STATUS current DESCRIPTION "This is the selection status for the reference. Its value is one of the following: Disabled, Disqualified, Qualified, or Selected. " ::= { tp5000eInputPQLEntry 3 } -- Symmetricom metrix sub-tree. -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.6.2 tp5000eSymmMetrics OBJECT IDENTIFIER ::= { tp5000eReferenceStatus 2 } -- The input reference configuration tree -- 1.3.6.1.4.1.9070.1.2.5.7.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7 tp5000eRefConfig OBJECT IDENTIFIER ::= { tp5000e 7 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.1 tp5000eRefTimingMode OBJECT-TYPE SYNTAX TP5000REFTIMINGMODE MAX-ACCESS read-write STATUS current DESCRIPTION "The timing mode of the entire TP5000E system, and it can be either Time (1) or Frequency (2). Whether the system is in Time or Frequency mode affects how time and frequency references are used in reference selection. A time reference has both frequency and time-of-day (TOD) information and can be used for both time and frequency synchronization. Examples of time references are: GNSS, GPS, 1PPT+TOD, and PTP. A frequency reference does not have TOD information and can be used only for frequency synchronization. Examples of frequency references are: 2048 kHz, 2048 kbps, 1544 kHz, 1544 kbps, SyncE, and 10 MHz." ::= { tp5000eRefConfig 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.2 tp5000eRefSelectionCriteria OBJECT-TYPE SYNTAX TP5000REFSELECTMODE MAX-ACCESS read-write STATUS current DESCRIPTION "Reference selection criteria applies to the entire TP5000E system, and it can be Priority based (2) or SSM based (3). Manual mode (1) is currently not supported. References are assigned priorities and PQL values, either by default or by user input. PQL values used to relate only to SSM values of E1/T1/SynE signals, but now PQL also covers time signals such as GNSS, GPS, and 1PPS+TOD. For a mapping for currently supported references, please see the user guide. " ::= { tp5000eRefConfig 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3 tp5000eRefConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eRefConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The reference configuration table is used to configure reference selection parameters for a specified reference input. Configuration parameters include reference name, reference enable state, reference priority, reference PQL enable state, and user configured PQL value. PQL (priority quality level) is reference quality used internal by the TP5000E system. Input SSM and other reference quality indicators are first mapped to PQL, and further processing is carried out using PQL. " ::= { tp5000eRefConfig 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1 tp5000eRefConfigEntry OBJECT-TYPE SYNTAX Tp5000eRefConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the reference configuration table. Table index is the ifIndex (port index)." INDEX { ifIndex, tp5000eRefName } ::= { tp5000eRefConfigTable 1 } Tp5000eRefConfigEntry ::= SEQUENCE { tp5000eRefName DisplayString, tp5000eRefState EnableValue, tp5000eRefPriority Integer32, tp5000eRefPQLState EnableValue, tp5000eRefPQL Integer32 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.2 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.1 tp5000eRefName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the reference. Examples: GNSS, GPS, E1, 1PPS+TOD." ::= { tp5000eRefConfigEntry 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.2 tp5000eRefState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Reference input state can be either Enable (1) or Disable (2). Only enabled references are used in reference selection." ::= { tp5000eRefConfigEntry 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.4 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.3 tp5000eRefPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Priority value assigned to a reference. Its range is 1 to 16. It is used as one of the selection criteria for reference selection." ::= { tp5000eRefConfigEntry 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.3.5.2.1.3 -- 1.3.6.1.4.1.9070.1.2.4.8.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.4 tp5000eRefPQLState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "The PQL state of a reference can be either Enable (1) or Disable (2). If PQL is enabled for a reference, the actual PQL value that the system uses either corresponds to the reference SSM value (when SSM is available) or is the default PQL value (when SSM is not available). If the PQL is disabled, the actual PQL value that the system uses matches the user configured reference PQL value (tp5000eRefPQL)." ::= { tp5000eRefConfigEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.7.3.1.5 tp5000eRefPQL OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Configured reference PQL value. Its range is 1 to 3, with 1 indicating the highest quality level. This PQL value is used when the reference PQL state is disabled, meaning 'do not use the PQL that comes with the reference but use this value.' This value along with disabling the PQL state is used to override the input PQL " ::= { tp5000eRefConfigEntry 5 } -- TP5000 evolution clock tree. -- 1.3.6.1.4.1.9070.1.2.5.7.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8 tp5000eClock OBJECT IDENTIFIER ::= { tp5000e 8 } -- TP5000 evolution clock status -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1 tp5000eClockStatus OBJECT IDENTIFIER ::= { tp5000eClock 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1 tp5000eClockStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eClockStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains status information for the clock in each shelf." ::= { tp5000eClockStatus 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1 tp5000eClockStatusEntry OBJECT-TYPE SYNTAX Tp5000eClockStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Clock Status Table. Table index is entPhysicalIndex (a shelf or a module)." INDEX { entPhysicalIndex, tp5000eClockStatusIndex } ::= { tp5000eClockStatusTable 1 } Tp5000eClockStatusEntry ::= SEQUENCE { tp5000eClockStatusIndex Integer32, tp5000eServoControlStatus TP5000SERVOCTL, tp5000ePhaseOffset DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.1 tp5000eClockStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the module clock status table." ::= { tp5000eClockStatusEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.2 tp5000eServoControlStatus OBJECT-TYPE SYNTAX TP5000SERVOCTL MAX-ACCESS read-only STATUS current DESCRIPTION "The clock servo status of clock module (IOC or expansion). This status is also called clock status in CLI. For expansion shelves, the clock status is the combined status of the cascaded main shelf clock and the expansion shelf clock. The clock status can be one of the following: (1) Warm-up (2) Free-run (3) Fast-track (4) Normal track (5) Holdover (6) Bridging (7) Fail (8) Offline (9) Extended holdover (10) Local free-run (11) Local holdover" ::= { tp5000eClockStatusEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.1.1.1.3 tp5000ePhaseOffset OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the phase offset in ns between the reference and output. This is applicable only when the selected reference is a time reference." ::= { tp5000eClockStatusEntry 3 } -- TP5000 evolution clock configuration tree. -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2 tp5000eClockConfig OBJECT IDENTIFIER ::= { tp5000eClock 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1 tp5000eBridgingTime OBJECT-TYPE SYNTAX Unsigned32 (100..200000) UNITS "Second" MAX-ACCESS read-write STATUS current DESCRIPTION "Bridging time in seconds. Range 100-200000. Default value Bridging is a clock state between normal tracking and holdover. When all references are lost, the clock declares that it is going into holdover after the bridging time has elapsed. During bridging, the clock maintains its specification for tracking. Default value is 900" ::= { tp5000eClockConfig 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.2 tp5000eAutoSync OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "The auto sync state can be either Enable (1) or Disable (2). Auto sync allows IOC time and IMC time to synchronize when IOC is in time mode passed warmup. If auto sync is disabled, an alarm will be generated when IOC and IMC times are not synchronized. Use tp5000eSync to remove this alarm condition." ::= { tp5000eClockConfig 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.3 tp5000eSync OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to force system time and phase to synchronize to the selected reference (synchronize between IMC and IOC). This object is write-only, and the value must be 'now.'" ::= { tp5000eClockConfig 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.4 tp5000eHoldoverExceededTimeQz OBJECT-TYPE SYNTAX Unsigned32 (0..3000000) UNITS "Seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "holdover time in seconds for holdover-exceeded-time-qz, Range (0|900-3000000). 0 is disable " ::= { tp5000eClockConfig 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.5 tp5000eHoldoverExceededTimeRb OBJECT-TYPE SYNTAX Unsigned32 (0..3000000) UNITS "Seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "holdover time in seconds for holdover-exceeded-time-rb, Range (0|900-3000000). 0 is disable " ::= { tp5000eClockConfig 5 } -- TP5000 evolution hardware hierarchy tree -- 1.3.6.1.4.1.9070.1.2.5.7.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9 tp5000eHardwareHierarchy OBJECT IDENTIFIER ::= { tp5000e 9 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1 tp5000eIfTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes physical hierarchy of TP5000E system down to the individual logical interface which can be a physical interface (like GPS port) or a virtual interface (like VLANs at an Ethernet port). " ::= { tp5000eHardwareHierarchy 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1 tp5000eIfEntry OBJECT-TYPE SYNTAX Tp5000eIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the TP5000E interface table. Table index is ifIndex." INDEX { tp5000eIfIndex } ::= { tp5000eIfTable 1 } Tp5000eIfEntry ::= SEQUENCE { tp5000eIfIndex Integer32, tp5000eIfModuleID TP5000MODULEID, tp5000eIfPortID Integer32, tp5000eIfTableIndex Unsigned32 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.1 tp5000eIfIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Local index of this table." ::= { tp5000eIfEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.2 tp5000eIfModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Module ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is only used to show the name of a physical module. It is not used as an index or sorting key. " ::= { tp5000eIfEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.3 tp5000eIfPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current inventory port ID. The range depends on the module ID and P/N index that together uniquely identify port configuration for each module. Example: range for IOC port ID is {1, 2}, and range for E1 expansion shelf is {1... 28}." ::= { tp5000eIfEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.4 tp5000eIfTableIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current interface index from ifTable. Each local index is mapped to a corresponding index in the ifTable." ::= { tp5000eIfEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2 tp5000eEntPhysicalTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eEntPhysicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes physical hierarchy of TP5000K system down to the module (container) level." ::= { tp5000eHardwareHierarchy 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1 tp5000eEntPhysicalEntry OBJECT-TYPE SYNTAX Tp5000eEntPhysicalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the TP5000E physical entity table. Each entry uniquely identifies the connector configuration (a module may have multiple versions with different connectors)." INDEX { tp5000eEntPhysicalIndex } ::= { tp5000eEntPhysicalTable 1 } Tp5000eEntPhysicalEntry ::= SEQUENCE { tp5000eEntPhysicalIndex Integer32, tp5000eEntPhysicalModuleID TP5000MODULEID, tp5000eEntPhysicalStackID Integer32, tp5000eEntPhysicalChassisID Integer32, tp5000eEntPhysicalPartIndex Integer32, tp5000eEntPhysicalTableIndex Integer32 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.1 tp5000eEntPhysicalIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "Local index of the TP5000E physical entity table." ::= { tp5000eEntPhysicalEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.2 tp5000eEntPhysicalModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Module ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is only used to show the name of a physical module. It is not used as an index or sorting key. " ::= { tp5000eEntPhysicalEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.3 tp5000eEntPhysicalStackID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Stack ID is the ID of the TP5000E system that the current module resides in. Stack ID is currently hardcoded to 1, and NMS needs to use other means (such as IP address) to identify each TP5000E system." ::= { tp5000eEntPhysicalEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.4 tp5000eEntPhysicalChassisID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis ID is the equipment shelf ID. In TP5000E system, there is one main shelf (chassis ID = 1) and up to ten expansion shelves (chassis ID range 2 to 11)." ::= { tp5000eEntPhysicalEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.5 tp5000eEntPhysicalPartIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Part number index uniquely identifies the connector configuration of a given module type. Currently, there are four versions of IMC, and the valid part number index value for IMC are IMC-1 (1), IMC-2 (2), IMC-3 (3), and IMC-4 (4). IOC only has two versions (Rb or Qz), and the valid part number index values for IOC are IOC-Rb (1) and IOC-Qz (2). There are four versions of I/O module, and therefore the range of the I/O module part number index is {1... 4}. Each type of expansion shelf currently does not have multiple versions, so their valid part number index value is only 1 at this time." ::= { tp5000eEntPhysicalEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.2.1.6 tp5000eEntPhysicalTableIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Each entry (module) in this table is mapped to an entity index in the entityPhysicalTable in the Entity-MIB." ::= { tp5000eEntPhysicalEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10 tp5000eVlanConfig OBJECT IDENTIFIER ::= { tp5000e 10 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1 tp5000eNonfixedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eNonfixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "In the non-fixed VLAN table, VLANs can be added or removed. As a VLAN is added or removed, the table index is updated. The non-fixed VLAN table can hold 484 VLANs (with IfIndex 17 to 500)." ::= { tp5000eVlanConfig 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1 tp5000eNonfixedVlanEntry OBJECT-TYPE SYNTAX Tp5000eNonfixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the non-fixed VLAN table. Table index is the local index, but each entry uniquely identifies a VLAN through the IfIndex." INDEX { tp5000eNonfixedVlanIndex } ::= { tp5000eNonfixedVlanTable 1 } Tp5000eNonfixedVlanEntry ::= SEQUENCE { tp5000eNonfixedVlanIndex Integer32, tp5000eNonfixedVlanIfIndex Unsigned32, tp5000eNonfixedVlanModuleID TP5000MODULEID, tp5000eNonfixedVlanPortID Integer32, tp5000eNonfixedVlanId INTEGER, tp5000eNonfixedVlanPriority Integer32, tp5000eNonfixedVlanIPv4Addr IpAddress, tp5000eNonfixedVlanNetmask IpAddress, tp5000eNonfixedVlanState EnableValue, tp5000eNonfixedVlanRowStatus RowStatus } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.1 tp5000eNonfixedVlanIndex OBJECT-TYPE SYNTAX Integer32 (1..100000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the non-fixed VLAN table." ::= { tp5000eNonfixedVlanEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.2 tp5000eNonfixedVlanIfIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "IfIndex of the current non-fixed VLAN (17-500)." ::= { tp5000eNonfixedVlanEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.3 tp5000eNonfixedVlanModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-create STATUS current DESCRIPTION "Module ID is the name of the physical module (the inventory module ID) in which the current non-fixed VLAN is defined. Module ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is only used to show the name of a physical module. It is not used as an index or sorting key. " ::= { tp5000eNonfixedVlanEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.4 tp5000eNonfixedVlanPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Physical port ID where the current non-fixed VLAN is defined. The range depends on the module ID and P/N index which together uniquely identify port configuration for each module. Example: range for IOC port ID is {1, 2}, and range for E1 expansion shelf is {1... 28}." ::= { tp5000eNonfixedVlanEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.5 tp5000eNonfixedVlanId OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID of the current VLAN interface. The range is 0~4094. If a VLAN ID is set to 0, the associated VLAN interface of this VLAN index will be removed from the internal VLAN table. The default VLAN ID of each VLAN interface in the VLAN table is 0. The VLAN ID can be set up only once. The VLAN ID and VLAN Priority must be configured at same time when a VLAN interface row is added. Once a VLAN ID is defined, it cannot be modified. To change it, set the VLAN ID to 0 (deleting the VLAN from the VLAN table) and create a new VLAN row. " ::= { tp5000eNonfixedVlanEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.6 tp5000eNonfixedVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "The priority of the VLAN ID. The range is 0 to 7. VLAN priority and VLAN ID must be configured at same time when a VLAN interface row is added. Once a VLAN priority is defined, it cannot be modified. To change it, set the VLAN ID to 0 (deleting the VLAN from the VLAN table), and create a new VLAN row." ::= { tp5000eNonfixedVlanEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.2.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.7 tp5000eNonfixedVlanIPv4Addr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The IPv4 address to which this entry's addressing information pertains. Implementers need to be aware that if the size of ipAddressAddr exceeds 116 octets, OIDS of instances of columns in this row will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3. " ::= { tp5000eNonfixedVlanEntry 7 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.8 tp5000eNonfixedVlanNetmask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The mask of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx. " ::= { tp5000eNonfixedVlanEntry 8 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.9 tp5000eNonfixedVlanState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "This is the state of an individual non-fixed VLAN. Value can be Enable (1) or Disable (2). Setting an individual VLAN state to Enable is not enough for the VLAN to become active. The physical VLAN mode must also be set to Enable (see tp5000eVlanModeTable)." ::= { tp5000eNonfixedVlanEntry 9 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.1.1.10 tp5000eNonfixedVlanRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of non-fixed VLAN table is used to control row actions. The status column has six defined actions (values): -`active(1)', which indicates that the conceptual row is available for use by the managed device; -`notInService(2)', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device; -`notReady(3)', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; -`createAndGo(4)', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device; -`createAndWait(5)', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device);and, -`destroy(6)', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. " ::= { tp5000eNonfixedVlanEntry 10 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2 tp5000eFixedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eFixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "In the fixed VLAN table, VLANs are pre-assigned to the VLAN table index. They cannot be added or removed from the table." ::= { tp5000eVlanConfig 2 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1 tp5000eFixedVlanEntry OBJECT-TYPE SYNTAX Tp5000eFixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the fixed VLAN table. Table index is ifIndex and local index." INDEX { ifIndex, tp5000eFixedVlanIndex } ::= { tp5000eFixedVlanTable 1 } Tp5000eFixedVlanEntry ::= SEQUENCE { tp5000eFixedVlanIndex Integer32, tp5000eFixedVlanId INTEGER, tp5000eFixedVlanPriority Integer32, tp5000eFixedVlanIPv4Addr IpAddress, tp5000eFixedVlanNetmask IpAddress, tp5000eFixedVlanGateway IpAddress, tp5000eFixedVlanState EnableValue } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.1 tp5000eFixedVlanIndex OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the fixed VLAN table." ::= { tp5000eFixedVlanEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.2 tp5000eFixedVlanId OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "The VLAN ID of the current VLAN interface. The range is 0~4094. If a VLAN ID is set to 0, the associated VLAN interface of this VLAN index will be removed from the internal VLAN table. The default VLAN ID of each VLAN interface in the VLAN table is 0. The VLAN ID can be setup only once. The VLAN ID and VLAN Priority must be configured at same time when a VLAN interface row is added. Once a VLAN ID is defined, it cannot be modified. To change it, set the VLAN ID to 0 (deleting the VLAN from the VLAN table) and create a new VLAN row. " ::= { tp5000eFixedVlanEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.3 tp5000eFixedVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "The priority of the VLAN ID. The range is 0 to 7. VLAN priority and VLAN ID must be configured at same time when a VLAN interface row is added. Once a VLAN priority is defined, it cannot be modified. To change it, set the VLAN ID to 0 (deleting the VLAN from the VLAN table), and create a new VLAN row." ::= { tp5000eFixedVlanEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.2.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.4 tp5000eFixedVlanIPv4Addr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv4 address to which this entry's addressing information pertains. Implementers need to be aware that if the size of ipAddressAddr exceeds 116 octets, OIDS of instances of columns in this row will have more than 128 sub-identifiers and cannot be accessed using SNMPv1, SNMPv2c, or SNMPv3. " ::= { tp5000eFixedVlanEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.5 tp5000eFixedVlanNetmask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The mask of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx. " ::= { tp5000eFixedVlanEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.2.1.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.6 tp5000eFixedVlanGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The gateway of an IPv4 interface. The address format is : xxx.xxx.xxx.xxx. " ::= { tp5000eFixedVlanEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.2.1.7 tp5000eFixedVlanState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is the state of an individual fixed VLAN. Value can be Enable (1) or Disable (2). Setting an individual VLAN state to Enable is not enough for the VLAN to become active. The physical port VLAN mode must also be set to Enable (see tp5000eVlanModeTable)." ::= { tp5000eFixedVlanEntry 7 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3 tp5000eVlanModeTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eVlanModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN mode table. The VLAN mode table is used to enable or disable all VLANs in a physical port." ::= { tp5000eVlanConfig 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1 tp5000eVlanModeEntry OBJECT-TYPE SYNTAX Tp5000eVlanModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the VLAN mode table. Table index is ifIndex (port and interface index) and local index." INDEX { ifIndex, tp5000eVlanModeIndex } ::= { tp5000eVlanModeTable 1 } Tp5000eVlanModeEntry ::= SEQUENCE { tp5000eVlanModeIndex Integer32, tp5000eVlanModeModuleID TP5000MODULEID, tp5000eVlanModePortID Integer32, tp5000eVlanModeValue EnableValue } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.1 tp5000eVlanModeIndex OBJECT-TYPE SYNTAX Integer32 (1..1000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local index of the VLAN mode table." ::= { tp5000eVlanModeEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.2 tp5000eVlanModeModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Module ID is the name of the physical module (the inventory module ID) in which the current VLAN is defined. Module ID is the name of the physical module. Its value can be one of the following: IMC (2), IOC1 (3), IOC2 (4), IO (5), exp0 (6),... exp9 (15). Module ID is only used to show the name of a physical module. It is not used as an index or sorting key. " ::= { tp5000eVlanModeEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.9.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.3 tp5000eVlanModePortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Physical port ID where the current VLAN is defined." ::= { tp5000eVlanModeEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.4.1.3.1.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.3.1.4 tp5000eVlanModeValue OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN mode for the specified physical port. Value can be Enable or Disable. This parameter can enable or disable all VLANs in this physical port, but setting the physical port VLAN mode to Enable is not enough for an individual VLAN to become active. That individual VLAN must also be enabled (see tp5000eVlanNonfixedVlanPortState and tp5000eVlanFixedVlanPortState)." ::= { tp5000eVlanModeEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4 tp5000eIPv6NonfixedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eIPv6NonfixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { tp5000eVlanConfig 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1 tp5000eIPv6NonfixedVlanEntry OBJECT-TYPE SYNTAX Tp5000eIPv6NonfixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { tp5000eIPv6NonfixedVlanIndex } ::= { tp5000eIPv6NonfixedVlanTable 1 } Tp5000eIPv6NonfixedVlanEntry ::= SEQUENCE { tp5000eIPv6NonfixedVlanIndex Integer32, tp5000eIPv6NonfixedVlanIfIndex Unsigned32, tp5000eIPv6NonfixedVlanModuleID TP5000MODULEID, tp5000eIPv6NonfixedVlanPortID Integer32, tp5000eIPv6NonfixedVlanId INTEGER, tp5000eIPv6NonfixedVlanPriority Integer32, tp5000eIPv6NonfixedVlanAddr InetAddressIPv6, tp5000eIPv6NonfixedVlanPrefix Integer32, tp5000eIPv6NonfixedVlanState EnableValue, tp5000eIPv6NonfixedVlanRowStatus RowStatus } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.1 tp5000eIPv6NonfixedVlanIndex OBJECT-TYPE SYNTAX Integer32 (1..100000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.2 tp5000eIPv6NonfixedVlanIfIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.3 tp5000eIPv6NonfixedVlanModuleID OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.4 tp5000eIPv6NonfixedVlanPortID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.5 tp5000eIPv6NonfixedVlanId OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.6 tp5000eIPv6NonfixedVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.7 tp5000eIPv6NonfixedVlanAddr OBJECT-TYPE SYNTAX InetAddressIPv6 MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 7 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.8 tp5000eIPv6NonfixedVlanPrefix OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 8 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.9 tp5000eIPv6NonfixedVlanState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 9 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.4.1.10 tp5000eIPv6NonfixedVlanRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6NonfixedVlanEntry 10 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5 tp5000eIPv6FixedVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eIPv6FixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { tp5000eVlanConfig 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1 tp5000eIPv6FixedVlanEntry OBJECT-TYPE SYNTAX Tp5000eIPv6FixedVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." INDEX { ifIndex, tp5000eIPv6FixedVlanIndex } ::= { tp5000eIPv6FixedVlanTable 1 } Tp5000eIPv6FixedVlanEntry ::= SEQUENCE { tp5000eIPv6FixedVlanIndex Integer32, tp5000eIPv6FixedVlanId INTEGER, tp5000eIPv6FixedVlanPriority Integer32, tp5000eIPv6FixedVlanAddr InetAddressIPv6, tp5000eIPv6FixedVlanPrefix Integer32, tp5000eIPv6FixedVlanDefaultRouter InetAddressIPv6, tp5000eIPv6FixedVlanState EnableValue } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.1 tp5000eIPv6FixedVlanIndex OBJECT-TYPE SYNTAX Integer32 (1..10000) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.2 tp5000eIPv6FixedVlanId OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.3 tp5000eIPv6FixedVlanPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.4 tp5000eIPv6FixedVlanAddr OBJECT-TYPE SYNTAX InetAddressIPv6 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.5 tp5000eIPv6FixedVlanPrefix OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.6 tp5000eIPv6FixedVlanDefaultRouter OBJECT-TYPE SYNTAX InetAddressIPv6 MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 6 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.10.5.1.7 tp5000eIPv6FixedVlanState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "Description." ::= { tp5000eIPv6FixedVlanEntry 7 } -- This sub-tree will include all alarm, event and client traps of TP5000 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11 tp5000eAlarmNotification OBJECT IDENTIFIER ::= { tp5000e 11 } -- The notification element definitions -- 1.3.6.1.4.1.9070.1.2.4.6.6.1 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1 tp5000eNotifyElements OBJECT IDENTIFIER ::= { tp5000eAlarmNotification 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.1 tp5000eNotifyModuleId OBJECT-TYPE SYNTAX TP5000MODULEID MAX-ACCESS read-only STATUS current DESCRIPTION "Module ID is the name of the physical module that generated the notification." ::= { tp5000eNotifyElements 1 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.2 tp5000eNotifyAlarmEventID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm or event ID of the notification." ::= { tp5000eNotifyElements 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.3 tp5000eNotifyIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Internal alarm index for a notification." ::= { tp5000eNotifyElements 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.3 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.4 tp5000eNotifySeverity OBJECT-TYPE SYNTAX ALARMLEVELTYPE MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm severity: 0 - clear alarm or event 2 - critical alarm (set, if non-transient) 3 - major alarm (set, if non-transient) 4 - minor alarm (set, if non-transient) 5 - report event (set, if non-transient) " ::= { tp5000eNotifyElements 4 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.1 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.5 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.5 tp5000eNotifyTransient OBJECT-TYPE SYNTAX TP5000TRANSIENT MAX-ACCESS read-only STATUS current DESCRIPTION "The transient state of an alarm or event. It is either a state event (non-transient) or a transient event (transient)." ::= { tp5000eNotifyElements 5 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.6 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.6 tp5000eNotifyDateTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time of the notification." DEFVAL { "" } ::= { tp5000eNotifyElements 6 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.7 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.7 tp5000eNotifyDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Description of this alarm or event (from the TP5000 internal alarm/event definition table)." DEFVAL { "" } ::= { tp5000eNotifyElements 7 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.8 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.8 tp5000eNotifyClientAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv4 address of TP5000's PTP client that generated the notification." ::= { tp5000eNotifyElements 8 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.9 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.9 tp5000eNotifySequenceNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The sequence number of a notification. Each notification OID (tp5000TrapAlarm, tp5000TrapEvent, and tp5000ClientNotification) has an independently incrementing sequence number. These are reset when the IMC is rebooted." ::= { tp5000eNotifyElements 9 } -- 1.3.6.1.4.1.9070.1.2.4.6.1.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.8 -- 1.3.6.1.4.1.9070.1.2.4.6.6.1.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.1.10 tp5000eNotifyClientClockID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Clock ID of the TP5000's PTP client that generated the notification." ::= { tp5000eNotifyElements 10 } -- 1.3.6.1.4.1.9070.1.2.4.6.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.2 tp5000eTrapAlarm NOTIFICATION-TYPE OBJECTS { tp5000eNotifyModuleId, tp5000eNotifyAlarmEventID, tp5000eNotifyIndex, tp5000eNotifySeverity, tp5000eNotifyTransient, tp5000eNotifyDateTime, tp5000eNotifyDescription, tp5000eNotifySequenceNum } STATUS current DESCRIPTION "TimeProvider 5000 alarm trap for the current notification. It contains the OID and value for module ID, alarm ID, notify index, severity, transient, date and time, severity, descriptions, and sequence number. OID names are defined in tp5000eNotifyElements." ::= { tp5000eAlarmNotification 2 } -- 1.3.6.1.4.1.9070.1.2.4.6.5.1 -- 1.3.6.1.4.1.9070.1.2.4.6.6.3 -- 1.3.6.1.4.1.9070.1.2.4.6.6.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.3 tp5000eTrapEvent NOTIFICATION-TYPE OBJECTS { tp5000eNotifyModuleId, tp5000eNotifyAlarmEventID, tp5000eNotifyIndex, tp5000eNotifySeverity, tp5000eNotifyTransient, tp5000eNotifyDateTime, tp5000eNotifyDescription, tp5000eNotifySequenceNum } STATUS current DESCRIPTION "TimeProvider 5000 event trap for the current notification. It contains the OIDs and values for module ID, event ID, notify index, severity, transient, date and time, severity, descriptions, and sequence number. OID names are defined in tp5000eNotifyElements." ::= { tp5000eAlarmNotification 3 } -- 1.3.6.1.4.1.9070.1.2.4.6.5.2 -- 1.3.6.1.4.1.9070.1.2.4.6.6.4 -- 1.3.6.1.4.1.9070.1.2.4.6.6.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.4 tp5000eClientNotification NOTIFICATION-TYPE OBJECTS { tp5000eNotifyModuleId, tp5000eNotifyAlarmEventID, tp5000eNotifyIndex, tp5000eNotifySeverity, tp5000eNotifyTransient, tp5000eNotifyDateTime, tp5000eNotifyDescription, tp5000eNotifyClientAddr, tp5000eNotifySequenceNum } STATUS current DESCRIPTION "TimeProvider 5000 PTP client trap for the current client notification. It contains the OID and value for alarm ID, index, severity, transient, date and time and descriptions, client IP address, client clock id, sequence number. OID names are defined in tp5000eNotifyElements." ::= { tp5000eAlarmNotification 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.11.5 tp5000ePtpMgmtEvent NOTIFICATION-TYPE OBJECTS { tp5000eNotifyModuleId, tp5000eNotifyAlarmEventID, tp5000eNotifyIndex, tp5000eNotifySeverity, tp5000eNotifyTransient, tp5000eNotifyDateTime, tp5000eNotifyDescription, tp5000eNotifyClientClockID, tp5000eNotifySequenceNum } STATUS current DESCRIPTION "Description." ::= { tp5000eAlarmNotification 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12 -- tp5000eIPv6GlobalConfig OBJECT IDENTIFIER ::= { tp5000e 12 } tp5000eIPv6GlobalConfig OBJECT IDENTIFIER ::= { tp5000e 12 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1 snmpIPv4IPv6ManagerTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpIPv4IPv6ManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to display SNMP manager info, such as managerID, EngineID, manager IP addresses, etc. This table's row only can be added or deleted. The existing row can not be modified. " ::= { tp5000eIPv6GlobalConfig 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1 snmpIPv4IPv6ManagerEntry OBJECT-TYPE SYNTAX SnmpIPv4IPv6ManagerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an entry in the Manager table. " INDEX { snmpIPv4IPv6ManagerIndex } ::= { snmpIPv4IPv6ManagerTable 1 } SnmpIPv4IPv6ManagerEntry ::= SEQUENCE { snmpIPv4IPv6ManagerIndex INTEGER, snmpIPv4IPv6ManagerID DisplayString, snmpIPv4IPv6ManagerAddress DisplayString, snmpIPv4IPv6ManagerEngineID DisplayString, snmpIPv4IPv6ManagerRowStatus RowStatus } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.1 snmpIPv4IPv6ManagerIndex OBJECT-TYPE SYNTAX INTEGER (1..3) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value for each user entry. This value ranges should be from 1 to 3." ::= { snmpIPv4IPv6ManagerEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.2 snmpIPv4IPv6ManagerID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SNMP manager ID or name which is used for SNMP v2 or v3 trap or notification." ::= { snmpIPv4IPv6ManagerEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.3 snmpIPv4IPv6ManagerAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP manager IP address. It can be IPv4 IPv6 " ::= { snmpIPv4IPv6ManagerEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.4 snmpIPv4IPv6ManagerEngineID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The SNMP management engineID. The format should be 0xDDDDDDDDDDDDDDDD, and minimum length is 14 and maximum length is 32 (including 0x as prefix)." ::= { snmpIPv4IPv6ManagerEntry 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.1.1.5 snmpIPv4IPv6ManagerRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The row status of SNMP manager table to control row actions. It has the following actions: The status column has six defined values: - `active(1)', which indicates that the conceptual row is available for use by the managed device; - `notInService(2)', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device (see NOTE below); - `notReady(3)', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - `createAndGo(4)', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device; - `createAndWait(5)', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device); and, - `destroy(6)', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. " ::= { snmpIPv4IPv6ManagerEntry 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2 tp5000eIPv4IPv6RemoteSyslogTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eIPv4IPv6RemoteSyslogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Remote syslog file control table. It is used to configure a remote syslog server to receive log messages from TP5000K system. Only one remote syslog server is supported at this time." ::= { tp5000eIPv6GlobalConfig 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1 tp5000eIPv4IPv6RemoteSyslogEntry OBJECT-TYPE SYNTAX Tp5000eIPv4IPv6RemoteSyslogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the remote syslog file control table." INDEX { tp5000eIPv4IPv6RemoteSyslogIndex } ::= { tp5000eIPv4IPv6RemoteSyslogTable 1 } Tp5000eIPv4IPv6RemoteSyslogEntry ::= SEQUENCE { tp5000eIPv4IPv6RemoteSyslogIndex Integer32, tp5000eIPv4IPv6RemoteSyslogState EnableValue, tp5000eIPv4IPv6RemoteSyslogAddr DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.1 tp5000eIPv4IPv6RemoteSyslogIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "The local index of the remote syslog file control table. At this time only the index value of 1 is supported." ::= { tp5000eIPv4IPv6RemoteSyslogEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.2 tp5000eIPv4IPv6RemoteSyslogState OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "The remote syslog state control. The setting can be either Enable (1) or Disable (2). Once this is set to Enable, all TP5000E log messages (intended for any of the four built-in logs) will be sent to the remote syslog server." DEFVAL { 2 } ::= { tp5000eIPv4IPv6RemoteSyslogEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1.3 tp5000eIPv4IPv6RemoteSyslogAddr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the remote syslog machine. It can be IPv4 or IPv6" ::= { tp5000eIPv4IPv6RemoteSyslogEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.3 tp5000eIPv4IPv6AuthRADIUSTable OBJECT-TYPE SYNTAX SEQUENCE OF Tp5000eIPv4IPv6AuthRADIUSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains IP addresses and access keys for the Radius authentication server. Radius enable state is set in tp5000eRadiusState outside of this table. " ::= { tp5000eIPv6GlobalConfig 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1 tp5000eIPv4IPv6AuthRADIUSEntry OBJECT-TYPE SYNTAX Tp5000eIPv4IPv6AuthRADIUSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of the RADIUS table. " INDEX { tp5000eIPv4IPv6AuthRADIUSIndex } ::= { tp5000eIPv4IPv6AuthRADIUSTable 1 } Tp5000eIPv4IPv6AuthRADIUSEntry ::= SEQUENCE { tp5000eIPv4IPv6AuthRADIUSIndex INTEGER, tp5000eIPv4IPv6ServerRADIUSIPAddress DisplayString, tp5000eIPv4IPv6AuthRADIUSKey DisplayString } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.1 tp5000eIPv4IPv6AuthRADIUSIndex OBJECT-TYPE SYNTAX INTEGER (1) MAX-ACCESS read-only STATUS current DESCRIPTION "A local index to the RADIUS table. Currently the system only supports RADIUS index value of 1. " ::= { tp5000eIPv4IPv6AuthRADIUSEntry 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.2 tp5000eIPv4IPv6ServerRADIUSIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The RADIUS server's IP address. It can be IPv4 or IPv6. An IP address cannot be set up if authRADIUS key value is none. " ::= { tp5000eIPv4IPv6AuthRADIUSEntry 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.3.1.3 tp5000eIPv4IPv6AuthRADIUSKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Authentication key for RADIUS server access." ::= { tp5000eIPv4IPv6AuthRADIUSEntry 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13 tp5000eConformance OBJECT-IDENTITY STATUS current DESCRIPTION "This subtree contains conformance statements for the Tp5000e MIB module. " ::= { tp5000e 13 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13.1 tp5000eCompliances OBJECT IDENTIFIER ::= { tp5000eConformance 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13.1.1 -- this module tp5000eBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Description." MODULE -- this module MANDATORY-GROUPS { tp5000eLEDGroup, tp5000eHWGroup, tp5000eModeUpTimeGroup, tp5000eModWarmUpGroup, tp5000eModStatusGroup, tp5000eActiveAlarmGroup, tp5000eActiveEventGroup, tp5000eAlarmConfigGroup, tp5000eGeneralAlarmGroup, tp5000eLogFileConfigGroup, tp5000eRemoteSyslogGroup, tp5000eRedundGroup, tp5000eImageGroup, tp5000eRebootGroup, tp5000eRadiusGroup, tp5000eAssetGroup, tp5000ePacketServiceGroup, tp5000eReferenceStatusGroup, tp5000eReferenceConfigGroup, tp5000eClockStatusGroup, tp5000eClockConfigGroup, tp5000eModuleIfGroup, tp5000eModuleEntityGroup, tp5000eNotifyGroup, tp5000eNotificationGroup, tp5000eFixedVlanGroup, tp5000eNonfixedVlanGroup, tp5000eVlanModeGroup,tp5000eIPv4IPv6SnmpManagerGroup, tp5000eIPv4IPv6AuthRADIUSGroup,tp5000eIPv4IPv6RemoteSyslogGroup} ::= { tp5000eCompliances 1 } -- 1.3.6.1.4.1.9070.1.2.4.8.1.6.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.1.6.2 -- 1.3.6.1.4.1.9070.1.2.4.6.1.8.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2 tp5000eUocGroups OBJECT IDENTIFIER ::= { tp5000eConformance 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.1 tp5000eLEDGroup OBJECT-GROUP OBJECTS { tp5000eLedID, tp5000eLedStatus } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 1 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.2 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.2 tp5000eHWGroup OBJECT-GROUP OBJECTS { tp5000eHWStatusInfo } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 2 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.3 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.3 tp5000eModeUpTimeGroup OBJECT-GROUP OBJECTS { tp5000eModuleUpTime } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 3 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.4 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.4 tp5000eModWarmUpGroup OBJECT-GROUP OBJECTS { tp5000eModWarmUpStatus } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 4 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.5 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.5 tp5000eModStatusGroup OBJECT-GROUP OBJECTS { tp5000eModStatusInfo } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 5 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.6 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.6 tp5000eActiveAlarmGroup OBJECT-GROUP OBJECTS { tp5000eActAlarmIndex, tp5000eActAlarmModID, tp5000eActAlarmID, tp5000eActAlarmDateTime, tp5000eActAlarmSeverity, tp5000eActAlarmDesc, tp5000eActAlarmInternalIndex } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 6 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.7 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.7 tp5000eActiveEventGroup OBJECT-GROUP OBJECTS { tp5000eActEventIndex, tp5000eActEventModID, tp5000eActEventID, tp5000eActEventInternlIndex, tp5000eActEventDateTime, tp5000eActEventDesc } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 7 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.8 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.8 tp5000eAlarmConfigGroup OBJECT-GROUP OBJECTS { tp5000eAlarmConfigIndex, tp5000eAlarmConfigAID, tp5000eAlarmLevelSetting, tp5000eAlarmSettingDelay, tp5000eEnableAlarmState, tp5000eAlarmConfigDesc } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 8 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.9 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.9 tp5000eGeneralAlarmGroup OBJECT-GROUP OBJECTS { tp5000eNumofStandingAlarm, tp5000eMessageGenerate } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 9 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.10 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.10 tp5000eLogFileConfigGroup OBJECT-GROUP OBJECTS { tp5000eLogFileConfigIndex, tp5000eLogFileTypeName, tp5000eLogFileBufferSize } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 10 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.11 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.11 tp5000eRemoteSyslogGroup OBJECT-GROUP OBJECTS { tp5000eRemoteSyslogIndex, tp5000eRemoteSyslogState, tp5000eRemoteSyslogAddr } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 11 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.12 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.12 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.12 tp5000eRedundGroup OBJECT-GROUP OBJECTS { tp5000eRedundModuleID, tp5000eRedundModState, tp5000eRedundActivePort } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 12 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.13 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.13 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.13 tp5000eImageGroup OBJECT-GROUP OBJECTS { tp5000eImageID, tp5000eImageNextBoot, tp5000eImageCurrState, tp5000eImageInfoMsg } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 13 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.15 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.15 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.15 tp5000eRebootGroup OBJECT-GROUP OBJECTS { tp5000eRebootAction } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 15 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.16 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.16 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.16 tp5000eRadiusGroup OBJECT-GROUP OBJECTS { tp5000eAuthRADIUSIndex, tp5000eServerRADIUSIPAddress, tp5000eAuthRADIUSKey, tp5000eRadiusState } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 16 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.17 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.17 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.17 tp5000eAssetGroup OBJECT-GROUP OBJECTS { tp5000eAssetNum, tp5000eIntraCommIPSet, tp5000eSSMOption } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 17 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.18 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.18 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.18 tp5000ePacketServiceGroup OBJECT-GROUP OBJECTS { tp5000ePacketServiceMode, tp5000ePTPClientDataTableLock, tp5000ePacketServiceExtendedMode } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 18 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.19 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.19 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.19 tp5000eReferenceStatusGroup OBJECT-GROUP OBJECTS { tp5000eInputRefName, tp5000eInputRefActualPQL, tp5000eInputRefQualified } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 19 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.20 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.20 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.20 tp5000eReferenceConfigGroup OBJECT-GROUP OBJECTS { tp5000eRefTimingMode, tp5000eRefSelectionCriteria, tp5000eRefName, tp5000eRefState, tp5000eRefPriority, tp5000eRefPQLState, tp5000eRefPQL } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 20 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.21 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.21 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.21 tp5000eClockStatusGroup OBJECT-GROUP OBJECTS { tp5000ePhaseOffset, tp5000eServoControlStatus } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 21 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.22 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.22 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.22 tp5000eClockConfigGroup OBJECT-GROUP OBJECTS { tp5000eBridgingTime, tp5000eAutoSync, tp5000eSync, tp5000eHoldoverExceededTimeQz, tp5000eHoldoverExceededTimeRb} STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 22 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.23 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.23 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.23 tp5000eModuleIfGroup OBJECT-GROUP OBJECTS { tp5000eIfIndex, tp5000eIfModuleID, tp5000eIfPortID, tp5000eIfTableIndex } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 23 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.24 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.24 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.24 tp5000eModuleEntityGroup OBJECT-GROUP OBJECTS { tp5000eEntPhysicalIndex, tp5000eEntPhysicalModuleID, tp5000eEntPhysicalStackID, tp5000eEntPhysicalChassisID, tp5000eEntPhysicalPartIndex, tp5000eEntPhysicalTableIndex } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 24 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.25 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.25 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.25 tp5000eFixedVlanGroup OBJECT-GROUP OBJECTS { tp5000eFixedVlanId, tp5000eFixedVlanPriority, tp5000eFixedVlanIPv4Addr, tp5000eFixedVlanNetmask, tp5000eFixedVlanGateway, tp5000eFixedVlanState } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 25 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.26 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.26 tp5000eNonfixedVlanGroup OBJECT-GROUP OBJECTS { tp5000eNonfixedVlanIfIndex, tp5000eNonfixedVlanModuleID, tp5000eNonfixedVlanPortID, tp5000eNonfixedVlanId, tp5000eNonfixedVlanPriority, tp5000eNonfixedVlanIPv4Addr, tp5000eNonfixedVlanNetmask, tp5000eNonfixedVlanRowStatus, tp5000eNonfixedVlanState } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 26 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.26 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.27 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.27 tp5000eNotifyGroup OBJECT-GROUP OBJECTS { tp5000eNotifyModuleId, tp5000eNotifyAlarmEventID, tp5000eNotifyIndex, tp5000eNotifySeverity, tp5000eNotifyTransient, tp5000eNotifyDateTime, tp5000eNotifyDescription, tp5000eNotifyClientAddr, tp5000eNotifySequenceNum, tp5000eNotifyClientClockID } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 27 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.27 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.28 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.28 tp5000eNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { tp5000eTrapAlarm, tp5000eTrapEvent, tp5000eClientNotification, tp5000ePtpMgmtEvent } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 28 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.29 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.29 tp5000eVlanModeGroup OBJECT-GROUP OBJECTS { tp5000eVlanModeModuleID, tp5000eVlanModeValue, tp5000eVlanModePortID } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 29 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.30 -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.30 tp5000eLastConfigGroup OBJECT-GROUP OBJECTS { tp5000eLastConfig } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 30 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.31 tp5000eIPv6NonfixedVlanGroup OBJECT-GROUP OBJECTS { tp5000eIPv6NonfixedVlanIfIndex, tp5000eIPv6NonfixedVlanModuleID, tp5000eIPv6NonfixedVlanPortID, tp5000eIPv6NonfixedVlanId, tp5000eIPv6NonfixedVlanPriority, tp5000eIPv6NonfixedVlanAddr, tp5000eIPv6NonfixedVlanPrefix, tp5000eIPv6NonfixedVlanState, tp5000eIPv6NonfixedVlanRowStatus } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 31 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.12.2.32 tp5000eIPv6FixedVlanGroup OBJECT-GROUP OBJECTS { tp5000eIPv6FixedVlanId, tp5000eIPv6FixedVlanPriority, tp5000eIPv6FixedVlanAddr, tp5000eIPv6FixedVlanPrefix, tp5000eIPv6FixedVlanDefaultRouter, tp5000eIPv6FixedVlanState } STATUS current DESCRIPTION "Description." ::= { tp5000eUocGroups 32 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13.2.33 tp5000eIPv4IPv6SnmpManagerGroup OBJECT-GROUP OBJECTS { snmpIPv4IPv6ManagerID, snmpIPv4IPv6ManagerAddress,snmpIPv4IPv6ManagerEngineID} STATUS current DESCRIPTION "Elements of tp5000eIPv4IPv6SnmpManagerTable" ::= { tp5000eUocGroups 33 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13.2.34 tp5000eIPv4IPv6RemoteSyslogGroup OBJECT-GROUP OBJECTS { tp5000eIPv4IPv6RemoteSyslogState,tp5000eIPv4IPv6RemoteSyslogAddr } STATUS current DESCRIPTION "Elements of tp5000eIPv4IPv6RemoteSyslogTable" ::= { tp5000eUocGroups 34 } -- 1.3.6.1.4.1.9070.1.2.5.7.1.13.2.35 tp5000eIPv4IPv6AuthRADIUSGroup OBJECT-GROUP OBJECTS { tp5000eIPv4IPv6ServerRADIUSIPAddress, tp5000eIPv4IPv6AuthRADIUSKey} STATUS current DESCRIPTION "Elements of tp5000eIPv4IPv6ServerRADIUSTable" ::= { tp5000eUocGroups 35 } END -- -- TP5000E.my --