TP5000E :: tp5000eRefTimingMode

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TP5000E › tp5000eRefTimingMode

tp5000eRefTimingMode

Module: TP5000E

OID (symbolic): TP5000E::tp5000eRefTimingMode

OID (numeric): 1.3.6.1.4.1.9070.1.2.5.7.1.7.1

Node type: OBJECT-TYPE

Type: TP5000REFTIMINGMODE

Access: read-write

Description: The timing mode of the entire TP5000E system, and it can be either Time (1) or Frequency (2). Whether the system is in Time or Frequency mode affects how time and frequency references are used in reference selection. A time reference has both frequency and time-of-day (TOD) information and can be used for both time and frequency synchronization.

Examples of time references are: GNSS, GPS, 1PPT+TOD, and PTP.

A frequency reference does not have TOD information and can be used only for frequency synchronization.

Examples of frequency references are: 2048 kHz, 2048 kbps, 1544 kHz, 1544 kbps, SyncE, and 10 MHz.

What is tp5000eRefTimingMode?

tp5000eRefTimingMode sets the system-wide timing mode to Time(1) or Frequency(2); Time mode lets the system use time-and-frequency-carrying references like GNSS/GPS/1PPS+TOD/PTP, while Frequency mode restricts it to frequency-only references like SyncE or 2048/1544 kHz/kbps signals.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.7.1
snmpwalk -v2c -c public <target> TP5000E::tp5000eRefTimingMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.7.1.1
snmpget -v2c -c public <target> TP5000E::tp5000eRefTimingMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9070.1.2.5.7.1.7.1.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> tp5000eRefTimingMode.1

Start monitoring Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TP5000E::tp5000eRefTimingMode OID value, configure state conditions and alerts, and monitor any Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9070symmetricomSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1symmNetworkManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2symmSnmpManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5symmCommonModelV1SYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5.7symmDeviceDependentSYMM-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9070.1.2.5.7.1tp5000eTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.7tp5000eRefConfigTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.7.1tp5000eRefTimingModeTP5000E