TP5000E :: tp5000eBridgingTime

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TP5000E › tp5000eBridgingTime

tp5000eBridgingTime

Module: TP5000E

OID (symbolic): TP5000E::tp5000eBridgingTime

OID (numeric): 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: Bridging time in seconds. Range 100-200000. Default value Bridging is a clock state between normal tracking and holdover. When all references are lost, the clock declares that it is going into holdover after the bridging time has elapsed. During bridging, the clock maintains its specification for tracking. Default value is 900

What is tp5000eBridgingTime?

tp5000eBridgingTime sets, in seconds (100-200000, default 900), how long the clock stays in the bridging state — maintaining spec while coasting — after all references are lost, before it formally declares holdover; an admin extends it to ride through longer reference outages without triggering a holdover alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1
snmpwalk -v2c -c public <target> TP5000E::tp5000eBridgingTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1.1
snmpget -v2c -c public <target> TP5000E::tp5000eBridgingTime.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1.1 i <value>

Start monitoring Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TP5000E::tp5000eBridgingTime OID value, configure state conditions and alerts, and monitor any Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9070symmetricomSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1symmNetworkManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2symmSnmpManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5symmCommonModelV1SYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5.7symmDeviceDependentSYMM-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9070.1.2.5.7.1tp5000eTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8tp5000eClockTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8.2tp5000eClockConfigTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.8.2.1tp5000eBridgingTimeTP5000E