TP5000E :: tp5000eActAlarmDesc

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TP5000E › tp5000eActAlarmDesc

tp5000eActAlarmDesc

Module: TP5000E

OID (symbolic): TP5000E::tp5000eActAlarmDesc

OID (numeric): 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: A description for the alarm. For a complete description of all alarms, 
please see the User Guide.

A portion of the alarm and event table is shown below:
ID  Level  State  Delay transient   Descriptions
---------------------------------------------------                               
0   critical  enable      0      no            Communication to peer card failed              
1   minor   enable   0      no         GNSS receiver communications failed               
2   minor   enable   0      no         GNSS receiver not tracking satellite              
3   major   enable   0      no         TOD source  invalid                            
4   event   enable   0      yes      TOD has been set by TOD source            
5   event   enable   0      yes      System log time has been updated               

What is tp5000eActAlarmDesc?

tp5000eActAlarmDesc is the human-readable description of this active alarm (e.g. 'GNSS receiver not tracking satellite' or 'TOD source invalid'), pulled from the device's built-in alarm/event definition table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7
snmpwalk -v2c -c public <target> TP5000E::tp5000eActAlarmDesc

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7.1
snmpget -v2c -c public <target> TP5000E::tp5000eActAlarmDesc.1

Start monitoring Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TP5000E::tp5000eActAlarmDesc OID value, configure state conditions and alerts, and monitor any Symmetricom TP5000e timing/synchronization system (module warm-up/active-alarm status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9070symmetricomSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1symmNetworkManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2symmSnmpManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5symmCommonModelV1SYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5.7symmDeviceDependentSYMM-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9070.1.2.5.7.1tp5000eTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.2tp5000eAlarmAndEventTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.2.1tp5000eActAlarmTableTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1tp5000eActAlarmEntryTP5000E
1.3.6.1.4.1.9070.1.2.5.7.1.2.1.1.7tp5000eActAlarmDescTP5000E