TN-IEEE8021-CFM-MIB :: tnDot1agCfmMcLagConfigStdbyInactive

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › TN-IEEE8021-CFM-MIB › tnDot1agCfmMcLagConfigStdbyInactive

tnDot1agCfmMcLagConfigStdbyInactive

Module: TN-IEEE8021-CFM-MIB

OID (symbolic): TN-IEEE8021-CFM-MIB::tnDot1agCfmMcLagConfigStdbyInactive

OID (numeric): 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: The value of tnDot1agCfmMcLagConfigStdbyInactive specifies whether or not ETH-CFM MEPs configured on Multi-Chassis LAG ports are aware of MC-LAG port active/standby states.

When this object is 'true (1)', MEPs configured on a Multi-Chassis LAG port will act as if they are administratively shutdown if running on a standby port, and will only be operational on an active MC-LAG port.

When this object is 'false (2)', MEPs configured on a Multi-Chassis LAG port will operate regardless of the MC-LAG port active and standby states.

What is tnDot1agCfmMcLagConfigStdbyInactive?

Controls whether ETH-CFM MEPs on Multi-Chassis LAG ports track MC-LAG active/standby state: when true, a MEP on a standby port behaves as if administratively shut down and only operates on the active port; when false, the default, MEPs run regardless of MC-LAG state.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1
snmpwalk -v2c -c public <target> TN-IEEE8021-CFM-MIB::tnDot1agCfmMcLagConfigStdbyInactive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1.1
snmpget -v2c -c public <target> TN-IEEE8021-CFM-MIB::tnDot1agCfmMcLagConfigStdbyInactive.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1.1 s <value>

Start monitoring Nokia 7x50 series carrier Ethernet/service router (802.1ag CFM MEP/AIS status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-IEEE8021-CFM-MIB::tnDot1agCfmMcLagConfigStdbyInactive OID value, configure state conditions and alerts, and monitor any Nokia 7x50 series carrier Ethernet/service router (802.1ag CFM MEP/AIS status) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7483tropicTROPIC-GLOBAL-REG
1.3.6.1.4.1.7483.6tnProductsTROPIC-GLOBAL-REG
1.3.6.1.4.1.7483.6.1tnSRMIBTROPIC-GLOBAL-REG
1.3.6.1.4.1.7483.6.1.2tnSRObjsTROPIC-GLOBAL-REG
Numeric OIDNameModule
1.3.6.1.4.1.7483.6.1.2.52tnDot1agMIBObjsTN-IEEE8021-CFM-MIB
1.3.6.1.4.1.7483.6.1.2.52.2tnDot1agCfmGlobalObjsTN-IEEE8021-CFM-MIB
1.3.6.1.4.1.7483.6.1.2.52.2.1tnDot1agCfmMcLagConfigTableTN-IEEE8021-CFM-MIB
1.3.6.1.4.1.7483.6.1.2.52.2.1.1tnDot1agCfmMcLagConfigEntryTN-IEEE8021-CFM-MIB
1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1tnDot1agCfmMcLagConfigStdbyInactiveTN-IEEE8021-CFM-MIB