All MIBs › TM62-MIB
Organization: Lanex
Last Updated: 2002-08-22
Description: TM62-MIB module
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TM62-MIB?
TM62-MIB is a small proprietary enterprise MIB, apparently from the Polish LANEX telecom equipment line (the module description is a Polish-language scaling comment, and sample objects reference 'lanex' and 'telecom'), for a device identified as TM62. It exposes basic device-identity objects (mainDeviceName, mainDeviceDescription, mainDeviceType, mainLNMPAddress, mainDevicePhysicalNumber) alongside an event log (logTable, logIndexLastEvent, logErase) and password-activity tracking. It is used to monitor both hardware and software status of the device: mainHardwareVersion and mainDeviceSoftwareVersion/mainSoftwareVersion expose the installed hardware revision and firmware version, logIndexLastEvent tracks the most recent logged event (useful for fault history), and mainPasswordActivity flags recent authentication activity for security auditing. It is a standalone enterprise MIB with no evident dependency on other MIBs beyond standard SNMPv2-SMI conventions. It is deployed on LANEX-branded telecom/power monitoring units where firmware version tracking and basic event-log review are needed, and technicians typically load it into a TM62-MIB MIB Browser session to inspect the device-identity and event-log objects directly.
IPNetwork Monitor allows you to monitor SNMP objects defined in TM62-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- LANEX telecom equipment (TM62 device)
- telecom/power monitoring unit
Monitoring Examples
An admin would poll mainDeviceSoftwareVersion and mainHardwareVersion across a fleet of TM62 units to confirm all devices are running the expected firmware revision before a maintenance window. logIndexLastEvent would be checked to see whether a new event (e.g. a fault or reset) has been logged since the last poll, with logErase available to clear the log after review. mainPasswordActivity would be monitored to flag unexpected password/authentication activity on the device.
What Can Be Monitored
- device name/description/type
- hardware version
- software version
- last logged event index
- password activity
- log erase status
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| ObjectName | |
| enterprises |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| lanex | 1.3.6.1.4.1.5746 | |||
| telecom | 1.3.6.1.4.1.5746.1 | |||
| optiLine4 | 1.3.6.1.4.1.5746.1.1 | |||
| main | 1.3.6.1.4.1.5746.1.1.1 | |||
| STR mainDeviceName | 1.3.6.1.4.1.5746.1.1.1.1 | DisplayString | read-write | Nazwa urzadzenia (tekst - 16 znakow) |
| STR mainDeviceDescription | 1.3.6.1.4.1.5746.1.1.1.2 | DisplayString | read-only | Tekstowy opis urzadzenia (tekst - 16 znakow) |
| INT mainDeviceType | 1.3.6.1.4.1.5746.1.1.1.3 | INTEGER | read-only | Typ urzadzenia: 44 - TM-44 49 - TM-60 60 - TM-60 61 - TM-61 62 - OptiLine 4 (TM-62) 63 - OptiLine 16 (TM-63) |
| INT mainHardwareVersion | 1.3.6.1.4.1.5746.1.1.1.4 | INTEGER | read-only | Wersja produkcyjna urzadzenia (np.TM-62.x ,gdzie x-wersja produkcyjna |
| I32 mainLNMPAddress | 1.3.6.1.4.1.5746.1.1.1.5 | Integer32 | read-only | Adres urzdzenia wykorzystany w protokole LNMP dla LanWin |
| INT mainDevicePhysicalNumber | 1.3.6.1.4.1.5746.1.1.1.6 | INTEGER | read-only | Numer fabryczny urzadzenia |
| INT mainDeviceSoftwareVersion | 1.3.6.1.4.1.5746.1.1.1.7 | INTEGER | read-only | Wersja kodu ukladu programowalnego np. 101 oznacza wersje 1.01 |
| INT mainSoftwareVersion | 1.3.6.1.4.1.5746.1.1.1.8 | INTEGER | read-only | Wersja oprogramowania np. wartosc 101 oznacza wersje 1.01 |
| INT mainPasswordActivity | 1.3.6.1.4.1.5746.1.1.1.9 | INTEGER | read-write | Aktywacja hasa dostpu do urzdzenia: 0 - haso nieaktywne 1- haso aktywne |
| OCT mainPassword | 1.3.6.1.4.1.5746.1.1.1.10 | OCTET STRING | read-write | Haslo dostepu do urzadzenia |
| DAT mainDateTime | 1.3.6.1.4.1.5746.1.1.1.11 | DateAndTime | read-write | Data i czas systemowy |
| configuration | 1.3.6.1.4.1.5746.1.1.2 | |||
| INT confLOES | 1.3.6.1.4.1.5746.1.1.2.1 | INTEGER | read-write | Zalaczanie/blokowanie kanalow skladowych 1-4 Rejestr ZKS jest 8 bitowy i ustawienie poszczeglnych bitow od bitu nr 0 do 3 na warto 1 powoduje zalonczenie, a ustawienie na 0 wylonczenie odpowiednio kanalu 1-4. bit : 3 2 1 0 nazwa : ZKS4 ZKS3 ZKS2 ZKS1 |
| INT confAlarmConfirm | 1.3.6.1.4.1.5746.1.1.2.3 | INTEGER | read-write | Kasowanie (potwierdzanie) alarmu 1- kasowanie |
| INT confTransmitterType | 1.3.6.1.4.1.5746.1.1.2.4 | INTEGER | read-write | Typ nadajnika bloku zbiorczego: 0-dioda laserowa, 1-dioda LED |
| INT confTransmitterStatus | 1.3.6.1.4.1.5746.1.1.2.5 | INTEGER | read-write | Ustawienie nadajnika laserowego: 0-wylaczony/automatyka, 1-pelna moc, 2-obnizona moc |
| INT confProgMAXTemperature | 1.3.6.1.4.1.5746.1.1.2.6 | INTEGER | read-only | Gorny dopuszczalny poziom temperatury w systemie (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT confProgMINTemperature | 1.3.6.1.4.1.5746.1.1.2.7 | INTEGER | read-only | Dolny dopuszczalny poziom temperatury w systemie (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT confProgMAX5V | 1.3.6.1.4.1.5746.1.1.2.10 | INTEGER | read-only | Gorny dopuszczalny poziom napiecia 5V (warto np. 527 oznacza napicie 5.27 V) |
| INT confProgMIN5V | 1.3.6.1.4.1.5746.1.1.2.11 | INTEGER | read-only | Dolny dopuszczalny poziom napiecia 5V (warto np. 527 oznacza napicie 5.27 V) |
| INT confProgMAX12V | 1.3.6.1.4.1.5746.1.1.2.12 | INTEGER | read-only | Gorny dopuszczalny poziom napiecia 12V (warto np. 1227 oznacza napicie 12.27 V) |
| INT confProgMIN12V | 1.3.6.1.4.1.5746.1.1.2.13 | INTEGER | read-only | Dolny dopuszczalny poziom napiecia 12V (warto np. 1227 oznacza napicie 12.27 V) |
| INT confProgMAXM12V | 1.3.6.1.4.1.5746.1.1.2.14 | INTEGER | read-only | Gorny dopuszczalny poziom napiecia -12V (warto np. 1227 oznacza napicie -12.27 V) |
| INT confProgMINM12V | 1.3.6.1.4.1.5746.1.1.2.15 | INTEGER | read-only | Dolny dopuszczalny poziom napiecia -12V (warto np. 1227 oznacza napicie -12.27 V) |
| status | 1.3.6.1.4.1.5746.1.1.3 | |||
| INT statLOES | 1.3.6.1.4.1.5746.1.1.3.1 | INTEGER | read-only | Stan rejestru Sygnalow Skladowych 1-4 Zanik sygnau skadowego przychodzcego do wejcia (ZSSx=1 - zanik sygnau, ZSSx=0 - sygna obecny, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : ZSS4 ZSS3 ZSS2 ZSS1 |
| INT statAISLM | 1.3.6.1.4.1.5746.1.1.3.2 | INTEGER | read-only | Stan rejestru Sygnalow AIS Lokalnych 1-4 Odbir sygnau AIS przez urzdzenie lokalne na wejciu (AISLx=1 - urzdzenie odbiera sygna AIS, AISLx=0 - brak sygnau AIS, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : AISL4 AISL3 AISL2 AISL1 |
| INT statAISRM | 1.3.6.1.4.1.5746.1.1.3.3 | INTEGER | read-only | Stan rejestru Sygnalow AIS Zdalnych 1-4 Odbir sygnau AIS przez urzdzenie lokalne na wejciu (AISZx=1 - urzdzenie odbiera sygna AIS, AISZx=0 - brak sygnau AIS, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : AISZ4 AISZ3 AISZ2 AISZ1 |
| INT statVIOL | 1.3.6.1.4.1.5746.1.1.3.4 | INTEGER | read-only | Stan rejestru Blad Wiolacji Sygnalu Skladowego 1-4 (BWSSx=1 - jest blad na kanale x, BWSSx=0 - brak bledu na kanale x, gdzie: x - numer kanalu). bit : 3 2 1 0 nazwa : BWSS4 BWSS3 BWSS2 BWSS1 |
| INT statBZSTAT | 1.3.6.1.4.1.5746.1.1.3.5 | INTEGER | read-only | Stan rejestru Status Bloku Zbiorczego BZSTAT jest rejestrem 8 bitowym. Znaczenie jego bitw: bit 5: ALZUZ-Alarm Zwrotny Z Urzdzenia Zdalnego (ALZUZ=1 - urzdzenie otrzymao sygna alarmu zwrotnego, ALZUZ=0 - brak sygnau alarmu zwrotnego). bit 4: 106K - Przekroczenie stopy 10-6 bdw kodowych w odebranym sygnale zbiorczym (E10_6=1 - nastpio przekroczenie, E10_6=0 - przekroczenie nie nastpio). bit 3: 103K - Przekroczenie stopy 10-3 bdw kodowych w odebranym sygnale zbiorczym (E10_3=1 - nastpio przekroczenie, E10_3=0 - przekroczenie nie nastpio). bit 2: USR - Utrata Synchronizacji Ramki bit 1: ZMN - Zanik Mocy Nadajnika (0 moc poprawna, 1 moc niepoprawna) bit 0: ZSO - Zanik Sygnau Optycznego na wejciu wiatowodowym |
| INT statSUS | 1.3.6.1.4.1.5746.1.1.3.6 | INTEGER | read-only | Stan rejestru Status Ukladu Sygnalizacji Bity sygnalizacji alarmw: bit 0: DALP - bit sygnalizacji alarmu pilnego lub zaniku alarmu po potwierdzeniu bit 1: DPALP - bit sygnalizacji przypomnienia alarmu pilnego bit 2: PALP - bit zaczenia przekanika alarmu pilnego bit 3: DALN - bit sygnalizacji alarmu niepilnego lub zaniku alarmu po potwierdzeniu bit 4: DPALN - bit sygnalizacji przypomnienia alarmu niepilnego bit 5: PALN - bit zaczenia przekanika alarmu niepilnego |
| INT statKJT | 1.3.6.1.4.1.5746.1.1.3.7 | INTEGER | read-only | Stan rejestru Kontrola Jakosci Transmisji Bity rejestru: bit 7: PSES24O - Wystpienie przekroczenia wartoci progowej dla rejestru SES,24 godzinnego, dla kierunku odbiorczego (PSES24O=1 - nastpio przekroczenie, PSES24O=0 - przekroczenie nie nastpio) bit 6: PSES24N - Wstpienie przekroczenia wartoci progowej dla rejestru SES, 24 godzinnego, dla kierunku nadawczego (PSES24N=1 - nastpio przekroczenie, PSES24N=0 - przekroczenie nie nastpio) bit 5: PES24O - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 24 godzinnego, dla kierunku odbiorczego (PES24O=1 - nastpio przekroczenie, PES24O=0 - przekroczenie nie nastpio) bit 4: PES24N - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 24 godzinnego, dla kierunku nadawczego (PES24N=1 - nastpio przekroczenie, PES24N=0 - przekroczenie nie nastpio) bit 3: PSES15O - Wystpienie przekroczenia wartoci progowej dla rejestru SES, 15 minutowego, dla kierunku odbiorczego (PSES15O=1 - nastpio przekroczenie, PSES15O=0 - przekroczenie nie nastpio) bit 2: PSES15N - Wystpienie przekroczenia wartoci progowej dla rejestru SES, 15 minutowego, dla kierunku nadawczego (PSES15N=1 - nastpio przekroczenie, PSES15N=0 - przekroczenie nie nastpio) bit 1: PES15O - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 15 minutowego, dla kierunku odbiorczego (PES15O=1 - nastpio przekroczenie, PES15O=0 - przekroczenie nie nastpio) bit 0: PES15N - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 15 minutowego, dla kierunku nadawczego (PES15N=1 - nastpio przekroczenie, PES15N=0 - przekroczenie nie nastpio) |
| HUN statTemperature | 1.3.6.1.4.1.5746.1.1.3.8 | Hundredths | read-only | Temperatura otoczenia systemu (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT stat5VVoltage | 1.3.6.1.4.1.5746.1.1.3.10 | INTEGER | read-only | Napiecie zasilania 5V (warto np. 527 oznacza napicie 5.27 V) |
| INT stat12VVoltage | 1.3.6.1.4.1.5746.1.1.3.11 | INTEGER | read-only | Napiecie zasilania 12V (warto np. 1227 oznacza napicie 12.27 V) |
| INT statM12VVoltage | 1.3.6.1.4.1.5746.1.1.3.12 | INTEGER | read-only | Napiecie zasilania -12V (warto np. 1227 oznacza napicie -12.27 V) |
| INT statExtremLevel | 1.3.6.1.4.1.5746.1.1.3.13 | INTEGER | read-only | Stan napi zasilajcych i temperatury otoczenia. Poszczeglne bity oznaczaj przekroczenie wartoci dopuszczalnej (progowej): (1 - przekroczenie wartosci progowej, 0 - wrtosc ponizej ustawionego progu) bit 1: napicia 5V bit 2: - napicia 12V bit 3: - napicia -12V bit 7: temperatury otoczenia |
| eventLog | 1.3.6.1.4.1.5746.1.1.4 | |||
| INT logIndexLastEvent | 1.3.6.1.4.1.5746.1.1.4.1 | INTEGER | read-only | Indeks do ostatnio wpisanego zdarzenia w historii dziennika zdarzen -1 oznacza pusty dziennik |
| INT logErase | 1.3.6.1.4.1.5746.1.1.4.2 | INTEGER | read-write | Kasowanie dziennika zdarzen ustawienie 1 - kasowanie |
| logTable | 1.3.6.1.4.1.5746.1.1.4.3 | not-accessible | Tabela opisuje dziennik zdarzen | |
| logEntry | 1.3.6.1.4.1.5746.1.1.4.3.1 | not-accessible | ||
| INT logIndex | 1.3.6.1.4.1.5746.1.1.4.3.1.1 | INTEGER | read-only | Indeks zdarzenia |
| STR logEventDescription | 1.3.6.1.4.1.5746.1.1.4.3.1.2 | DisplayString | read-only | Opis Zdarzenia: YYYY/MM/DD HH:MM.SS ZZZ YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta SS - sekunda ZZZ - identyfikator zdarzenia |
| es | 1.3.6.1.4.1.5746.1.1.5 | |||
| INT esLastES15T | 1.3.6.1.4.1.5746.1.1.5.1 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES15N w tablicy licznikow |
| INT esLastES15R | 1.3.6.1.4.1.5746.1.1.5.2 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES15O w tablicy licznikow |
| INT esLastSES15T | 1.3.6.1.4.1.5746.1.1.5.3 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES15N w tablicy licznikow |
| INT esLastSES15R | 1.3.6.1.4.1.5746.1.1.5.4 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES15O w tablicy licznikow |
| INT esLastES24T | 1.3.6.1.4.1.5746.1.1.5.5 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES24N w tablicy licznikow |
| INT esLastES24R | 1.3.6.1.4.1.5746.1.1.5.6 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES24O w tablicy licznikow |
| INT esLastSES24T | 1.3.6.1.4.1.5746.1.1.5.7 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES24N w tablicy licznikow |
| INT esLastSES24R | 1.3.6.1.4.1.5746.1.1.5.8 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES24O w tablicy licznikow |
| INT esErase | 1.3.6.1.4.1.5746.1.1.5.9 | INTEGER | read-write | Kasowanie rejestrw Es/Ses ustawienie 1 - kasowanie |
| INT esESAlarm | 1.3.6.1.4.1.5746.1.1.5.10 | INTEGER | read-write | Aktywacja alarmu przekroczenia wartoci progowej ES lub SES 0 nieaktywny 1 aktywny |
| INT esES15On | 1.3.6.1.4.1.5746.1.1.5.11 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu niepilnego w okresie 15 min. (0-900) |
| INT esES15Off | 1.3.6.1.4.1.5746.1.1.5.12 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu niepilnego w okresie 15 min. (0-900) |
| INT esSES15On | 1.3.6.1.4.1.5746.1.1.5.13 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu pilnego w okresie 15 min. (0-900) |
| INT esSES15Off | 1.3.6.1.4.1.5746.1.1.5.14 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu pilnego w okresie 15 min. (0-900) |
| INT esES24On | 1.3.6.1.4.1.5746.1.1.5.15 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
| INT esES24Off | 1.3.6.1.4.1.5746.1.1.5.16 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
| INT esSES24On | 1.3.6.1.4.1.5746.1.1.5.17 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu pilnego w okresie 24 h. (0-86400) |
| INT esSES24Off | 1.3.6.1.4.1.5746.1.1.5.18 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu pilnego w okresie 24 h. (0-86400) |
| INT esESSESHour | 1.3.6.1.4.1.5746.1.1.5.19 | INTEGER | read-write | Godzina rozpoczecia zliczania w rejestrach ES i SES |
| INT esESSESMinute | 1.3.6.1.4.1.5746.1.1.5.20 | INTEGER | read-write | Minuta rozpoczecia zliczania w rejestrach ES i SES |
| esTableES15T | 1.3.6.1.4.1.5746.1.1.5.21 | not-accessible | Tabela opisuje zapis licznikow ES15N | |
| esEntryES15T | 1.3.6.1.4.1.5746.1.1.5.21.1 | not-accessible | ||
| INT esIndexES15T | 1.3.6.1.4.1.5746.1.1.5.21.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES15T | 1.3.6.1.4.1.5746.1.1.5.21.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableES15R | 1.3.6.1.4.1.5746.1.1.5.22 | not-accessible | Tabela opisuje zapis licznika ES15O | |
| esEntryES15R | 1.3.6.1.4.1.5746.1.1.5.22.1 | not-accessible | ||
| INT esIndexES15R | 1.3.6.1.4.1.5746.1.1.5.22.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES15R | 1.3.6.1.4.1.5746.1.1.5.22.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableSES15T | 1.3.6.1.4.1.5746.1.1.5.23 | not-accessible | Tabela opisuje zapis licznika SES15N | |
| esEntrySES15T | 1.3.6.1.4.1.5746.1.1.5.23.1 | not-accessible | ||
| INT esIndexSES15T | 1.3.6.1.4.1.5746.1.1.5.23.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES15T | 1.3.6.1.4.1.5746.1.1.5.23.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableSES15R | 1.3.6.1.4.1.5746.1.1.5.24 | not-accessible | Tabela opisuje zapis licznika SES15O | |
| esEntrySES15R | 1.3.6.1.4.1.5746.1.1.5.24.1 | not-accessible | ||
| INT esIndexSES15R | 1.3.6.1.4.1.5746.1.1.5.24.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES15R | 1.3.6.1.4.1.5746.1.1.5.24.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableES24T | 1.3.6.1.4.1.5746.1.1.5.25 | not-accessible | Tabela opisuje zapis licznika ES24N | |
| esEntryES24T | 1.3.6.1.4.1.5746.1.1.5.25.1 | not-accessible | ||
| INT esIndexES24T | 1.3.6.1.4.1.5746.1.1.5.25.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES24T | 1.3.6.1.4.1.5746.1.1.5.25.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableES24R | 1.3.6.1.4.1.5746.1.1.5.26 | not-accessible | Tabela opisuje zapis licznika ES24O | |
| esEntryES24R | 1.3.6.1.4.1.5746.1.1.5.26.1 | not-accessible | ||
| INT esIndexES24R | 1.3.6.1.4.1.5746.1.1.5.26.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES24R | 1.3.6.1.4.1.5746.1.1.5.26.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableSES24T | 1.3.6.1.4.1.5746.1.1.5.27 | not-accessible | Tabela opisuje zapis licznika SES24N | |
| esEntrySES24T | 1.3.6.1.4.1.5746.1.1.5.27.1 | not-accessible | ||
| INT esIndexSES24T | 1.3.6.1.4.1.5746.1.1.5.27.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES24T | 1.3.6.1.4.1.5746.1.1.5.27.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableSES24R | 1.3.6.1.4.1.5746.1.1.5.28 | not-accessible | Tabela opisuje zapis licznika SES24O | |
| esEntrySES24R | 1.3.6.1.4.1.5746.1.1.5.28.1 | not-accessible | ||
| INT esIndexSES24R | 1.3.6.1.4.1.5746.1.1.5.28.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES24R | 1.3.6.1.4.1.5746.1.1.5.28.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| test | 1.3.6.1.4.1.5746.1.1.6 | |||
| INT testTributaryChannLoopType1 | 1.3.6.1.4.1.5746.1.1.6.1 | INTEGER | read-write | Zalaczenie petli kanalu skladowego 1 - 4 do interfejsu. (ALx = 1 zaczenie ptli, ALx = 0 wyczene ptli na kanale x) bit : 3 2 1 0 nazwa : AL4 AL3 AL2 AL1 |
| INT testGeneratorDetector | 1.3.6.1.4.1.5746.1.1.6.5 | INTEGER | read-write | numer generatora/detektora wykorzystywanego do testu 1..4 - generator w kierunku kanalu skladowego (E1) 1..4 |
| INT testGCT | 1.3.6.1.4.1.5746.1.1.6.6 | INTEGER | read-write | Sterowanie zaczaniem/wyczaniem generatorw testowych wybranych kanaw skladowych/zbiorczych: 1 generator zaczony 0 generator wyczony |
| INT testTime | 1.3.6.1.4.1.5746.1.1.6.7 | INTEGER | read-write | Deklarowany czas trwania testu w sekundach. Maks. 24 godziny |
| INT testSyncTime | 1.3.6.1.4.1.5746.1.1.6.8 | INTEGER | read-only | czas pomiaru gdy jest synchronizacja |
| INT testNoSyncTime | 1.3.6.1.4.1.5746.1.1.6.9 | INTEGER | read-only | czas pomiaru gdy brak synchronizacji |
| I32 testErrorsPerSec | 1.3.6.1.4.1.5746.1.1.6.10 | Integer32 | read-only | Biezaca liczba bledow w cyklu sekundowym |
| I32 testTotalErrorNumber | 1.3.6.1.4.1.5746.1.1.6.11 | Integer32 | read-only | Calkowita liczba bledow |
| STR testBER | 1.3.6.1.4.1.5746.1.1.6.12 | DisplayString | read-write | Stopa bledow w formacie: P.Pe-LL (notacja naukowa) przyklad: 2.3e-09 |
| INT testSyncYesNo | 1.3.6.1.4.1.5746.1.1.6.16 | INTEGER | read-only | Flaga synchronizacji (1 oznacza detekcj cigu testowego) |
| INT testStatus | 1.3.6.1.4.1.5746.1.1.6.17 | INTEGER | read-only | status wykonywania testu 0 OFF test wyczony 1 ON test zaczony 2 RUN test trwa 3 READY gotowo do rozpoczcia testu 4 WAIT_ON oczekiwanie na zaczenie testu 5 WAIT_OFF oczekiwanie na wyczenie testu 6 WAIT oczekiwanie |
| optiLine4MIBNotifications | 1.3.6.1.4.1.5746.1.1.7 | |||
| mibNotificationsPrefix | 1.3.6.1.4.1.5746.1.1.7.0 | |||
| NTF trapOptiLine4ALPActive | 1.3.6.1.4.1.5746.1.1.7.0.1 | Aktywny Alarm pilny | ||
| NTF trapOptiLine4ALNActive | 1.3.6.1.4.1.5746.1.1.7.0.2 | Aktywny Alarm niepilny | ||
| NTF trapOptiLine4LogIdn | 1.3.6.1.4.1.5746.1.1.7.0.3 | Wystapienie zdarzenia w urzadzeniu: 1.Zapis do lokalnego dziennika zdarzen 2.Przekazanie identyfikatora zdarzenia w trapie | ||
| NTF trapOptiLine4Es | 1.3.6.1.4.1.5746.1.1.7.0.4 | Zmiana w licznikach es/ses | ||
| NTF trapOptiLine4confn | 1.3.6.1.4.1.5746.1.1.7.0.5 | Zapis do zmiennej z grupy knfiguracja, n - identyfikator elementu, ktory zostal zmodyfikowany | ||
| NTF trapOptiLine4ALPInactive | 1.3.6.1.4.1.5746.1.1.7.0.6 | Nieaktywny Alarm pilny | ||
| NTF trapOptiLine4ALNInactive | 1.3.6.1.4.1.5746.1.1.7.0.7 | Nieaktywny Alarm niepilny | ||
| optiLine4MIBObjects | 1.3.6.1.4.1.5746.1.1.7.1 | |||
| INT obEventIdn | 1.3.6.1.4.1.5746.1.1.7.1.1 | INTEGER | read-only | Nr zdarzenia |
| STR obEventDescription | 1.3.6.1.4.1.5746.1.1.7.1.2 | DisplayString | read-only | Opis zdarzenia |
RFC description
Management and monitoring for Lanex OptiLine 4 (TM62) optical transmission equipment.
Start monitoring LANEX telecom/power monitoring unit, TM62 device (firmware version/event-log status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.