TM62-MIB :: stat5VVoltage

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TM62-MIB › stat5VVoltage

stat5VVoltage

Module: TM62-MIB

OID (symbolic): TM62-MIB::stat5VVoltage

OID (numeric): 1.3.6.1.4.1.5746.1.1.3.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Napiecie zasilania 5V (warto np. 527 oznacza napicie 5.27 V)

What is stat5VVoltage?

The device's current +5V supply rail reading, expressed in hundredths of a volt (e.g. 527 meaning 5.27 V), checked against the configured min/max thresholds to catch power-supply drift.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5746.1.1.3.10
snmpwalk -v2c -c public <target> TM62-MIB::stat5VVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5746.1.1.3.10.1
snmpget -v2c -c public <target> TM62-MIB::stat5VVoltage.1

Start monitoring LANEX telecom/power monitoring unit, TM62 device (firmware version/event-log status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TM62-MIB::stat5VVoltage OID value, configure state conditions and alerts, and monitor any LANEX telecom/power monitoring unit, TM62 device (firmware version/event-log status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5746lanexTM62-MIB
1.3.6.1.4.1.5746.1telecomTM62-MIB
1.3.6.1.4.1.5746.1.1optiLine4TM62-MIB
1.3.6.1.4.1.5746.1.1.3statusTM62-MIB
1.3.6.1.4.1.5746.1.1.3.10stat5VVoltageTM62-MIB