All MIBs › TM63-MIB
Organization: Lanex
Last Updated: 2001-12-14
Description: TM63-MIB module
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TM63-MIB?
TM63-MIB is a vendor-specific SNMP MIB for a telecom transmission device; internal naming ("lanex", "telecom") points to LANEX, a Polish manufacturer of telecom transmission/multiplexing equipment, with TM63 designating a specific hardware platform. It exposes basic device-identity data (name, description, type, physical number), firmware/hardware version strings, password/security activity, transmitter configuration, and environmental readings such as internal temperature and a 3V supply voltage. It is explicitly built for monitoring the hardware and software status of the unit: hardware version and software version for inventory/compliance checks, and low-level health telemetry like the programmed minimum temperature threshold and 3V rail voltage for detecting environmental or power faults. No dependency on other standard MIBs is evident from the available fields, suggesting a largely self-contained enterprise MIB. It is deployed on LANEX-style telecom transmission/multiplexer equipment at telecom access or transport network sites, likely in Eastern European carrier networks. Engineers can download the TM63-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TM63-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Lanex telecom transmission equipment
Monitoring Examples
An administrator polls mainDeviceSoftwareVersion and mainHardwareVersion to confirm the unit is on the expected firmware/hardware combination before a maintenance change. confProgMINTemperature is compared against the device's actual temperature reading to catch a unit approaching its lower operating limit, e.g., in an unheated outdoor cabinet. stat3VVoltage is monitored for drift from nominal 3V, indicating a failing power supply or backup battery. The module's note about converting "1234 to 12.34" indicates raw integer readings like voltage are scaled by 100 and must be divided accordingly by monitoring tools.
What Can Be Monitored
- hardware version
- software version
- device name/description/type
- internal/minimum programmed temperature
- 3V supply voltage
- password/security activity
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| ObjectName | |
| enterprises |
From SNMPv2-TC
| DateAndTime | |
| DisplayString | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| lanex | 1.3.6.1.4.1.5746 | |||
| telecom | 1.3.6.1.4.1.5746.1 | |||
| optiLine16 | 1.3.6.1.4.1.5746.1.2 | |||
| main | 1.3.6.1.4.1.5746.1.2.1 | |||
| STR mainDeviceName | 1.3.6.1.4.1.5746.1.2.1.1 | DisplayString | read-write | Nazwa urzadzenia (tekst - 16 znakow) |
| STR mainDeviceDescription | 1.3.6.1.4.1.5746.1.2.1.2 | DisplayString | read-only | Tekstowy opis urzadzenia (tekst - 16 znakow) |
| INT mainDeviceType | 1.3.6.1.4.1.5746.1.2.1.3 | INTEGER | read-only | Typ urzadzenia: 44 - TM-44 49 - TM-60 60 - TM-60 61 - TM-61 62 - OptiLine 4 (TM-62) 63 - OptiLine 16 (TM-63) |
| INT mainHardwareVersion | 1.3.6.1.4.1.5746.1.2.1.4 | INTEGER | read-only | Wersja produkcyjna urzadzenia (np.TM-63.x ,gdzie x-wersja produkcyjna |
| I32 mainLNMPAddress | 1.3.6.1.4.1.5746.1.2.1.5 | Integer32 | read-only | Adres urzdzenia wykorzystany w protokole LNMP dla LanWin |
| INT mainDevicePhysicalNumber | 1.3.6.1.4.1.5746.1.2.1.6 | INTEGER | read-only | Numer fabryczny urzadzenia |
| INT mainDeviceSoftwareVersion | 1.3.6.1.4.1.5746.1.2.1.7 | INTEGER | read-only | Wersja kodu ukladu programowalnego np. 101 oznacza wersje 1.01 |
| INT mainSoftwareVersion | 1.3.6.1.4.1.5746.1.2.1.8 | INTEGER | read-only | Wersja oprogramowania np. wartosc 101 oznacza wersje 1.01 |
| INT mainPasswordActivity | 1.3.6.1.4.1.5746.1.2.1.9 | INTEGER | read-write | Aktywacja hasa dostpu do urzdzenia: 0 - haso nieaktywne 1- haso aktywne |
| OCT mainPassword | 1.3.6.1.4.1.5746.1.2.1.10 | OCTET STRING | read-write | Haslo dostepu do urzadzenia |
| DAT mainDateTime | 1.3.6.1.4.1.5746.1.2.1.11 | DateAndTime | read-write | Data i czas systemowy |
| configuration | 1.3.6.1.4.1.5746.1.2.2 | |||
| INT confLOES | 1.3.6.1.4.1.5746.1.2.2.1 | INTEGER | read-write | Zalaczanie/blokowanie kanalow skladowych 1-16 Rejestr ZKS jest 16 bitowy i ustawienie poszczeglnych bitow od bitu nr 0 do 15 na warto 1 powoduje zalonczenie, a ustawienie na 0 wylonczenie odpowiednio kanalu 1-16. bit : 15 14 13 12 11 10 9 8 nazwa : ZKS16 ZKS15 ZKS14 ZKS13 ZKS12 ZKS11 ZKS10 ZKS9 bit : 7 6 5 4 3 2 1 0 nazwa : ZKS8 ZKS7 ZKS6 ZKS5 ZKS4 ZKS3 ZKS2 ZKS1 |
| INT confAISL | 1.3.6.1.4.1.5746.1.2.2.2 | INTEGER | read-write | Generowanie sygnalu AIS w odpowiednim kanale skladowym 1-16 Wymuszenie przesania sygnau AIS do odpowiednich kanaw skadowych (AISLKx = 1 -wymuszenie przesyania sygnau AIS do kanau skadowego nr x) bit : 15 14 13 12 11 10 9 8 nazwa : AISL16 AISL15 AISL14 AISL13 AISL12 AISL11 AISL10 AISL9 bit : 7 6 5 4 3 2 1 0 nazwa : AISL8 AISL7 AISL6 AISL5 AISL4 AISL3 AISL2 AISL1 |
| INT confAlarmConfirm | 1.3.6.1.4.1.5746.1.2.2.3 | INTEGER | read-write | Kasowanie (potwierdzanie) alarmu 1- kasowanie |
| INT confTransmitterType | 1.3.6.1.4.1.5746.1.2.2.4 | INTEGER | read-write | Typ nadajnika bloku zbiorczego: 0-dioda laserowa, 1-dioda LED, 2-elektryczny E3 |
| INT confTransmitterStatus | 1.3.6.1.4.1.5746.1.2.2.5 | INTEGER | read-write | Ustawienie nadajnika laserowego: 0-wylaczony/automatyka, 1-pelna moc, 2-obnizona moc |
| INT confProgMAXTemperature | 1.3.6.1.4.1.5746.1.2.2.6 | INTEGER | read-only | Gorny dopuszczalny poziom temperatury w systemie (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT confProgMINTemperature | 1.3.6.1.4.1.5746.1.2.2.7 | INTEGER | read-only | Dolny dopuszczalny poziom temperatury w systemie (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT confProgMAX3V | 1.3.6.1.4.1.5746.1.2.2.8 | INTEGER | read-only | Gorny dopuszczalny poziom napiecia 3.3V (warto np. 327 oznacza napicie 3.27V) |
| INT confProgMIN3V | 1.3.6.1.4.1.5746.1.2.2.9 | INTEGER | read-only | Dolny dopuszczalny poziom napiecia 3.3V (warto np. 327 oznacza napicie 3.27V) |
| INT confProgMAX5V | 1.3.6.1.4.1.5746.1.2.2.10 | INTEGER | read-only | Gorny dopuszczalny poziom napiecia 5V (warto np. 527 oznacza napicie 5.27V) |
| INT confProgMIN5V | 1.3.6.1.4.1.5746.1.2.2.11 | INTEGER | read-only | Dolny dopuszczalny poziom napiecia 5V (warto np. 527 oznacza napicie 5.27V) |
| status | 1.3.6.1.4.1.5746.1.2.3 | |||
| INT statLOES | 1.3.6.1.4.1.5746.1.2.3.1 | INTEGER | read-only | Stan rejestru Sygnalow Skladowych 1-16 Zanik sygnau skadowego przychodzcego do wejcia (ZSSx=1 - zanik sygnau, ZSSx=0 - sygna obecny, gdzie: x - numer kanalu). bit : 15 14 13 12 11 10 9 8 nazwa : ZSS16 ZSS15 ZSS14 ZSS13 ZSS12 ZSS11 ZSS10 ZSS9 bit : 7 6 5 4 3 2 1 0 nazwa : ZSS8 ZSS7 ZSS6 ZSS5 ZSS4 ZSS3 ZSS2 ZSS1 |
| INT statAISLM | 1.3.6.1.4.1.5746.1.2.3.2 | INTEGER | read-only | Stan rejestru Sygnalow AIS Lokalnych 1-16 Odbir sygnau AIS przez urzdzenie lokalne na wejciu (AISLx=1 - urzdzenie odbiera sygna AIS, AISLx=0 - brak sygnau AIS, gdzie: x - numer kanalu). bit : 15 14 13 12 11 10 9 8 nazwa : AISL16 AISL15 AISL14 AISL13 AISL12 AISL11 AISL10 AISL9 bit : 7 6 5 4 3 2 1 0 nazwa : AISL8 AISL7 AISL6 AISL5 AISL4 AISL3 AISL2 AISL1 |
| INT statVIOL | 1.3.6.1.4.1.5746.1.2.3.4 | INTEGER | read-only | Stan rejestru Blad Wiolacji Sygnalu Skladowego 1-16 (BWSSx=1 - jest blad na kanale x, BWSSx=0 - brak bledu na kanale x, gdzie: x - numer kanalu). bit : 15 14 13 12 11 10 9 8 nazwa : BWSS16 BWSS15 BWSS14 BWSS13 BWSS12 BWSS11 BWSS10 BWSS9 bit : 7 6 5 4 3 2 1 0 nazwa : BWSS8 BWSS7 BWSS6 BWSS5 BWSS4 BWSS3 BWSS2 BWSS1 |
| INT statBZSTAT | 1.3.6.1.4.1.5746.1.2.3.5 | INTEGER | read-only | Stan rejestru Status Bloku Zbiorczego BZSTAT jest rejestrem 8 bitowym. Znaczenie jego bitw: bit 7: L_OFF - stan pracy lasera (0 wczony, 1-wyczony) bit 6: BWSS - Bd wiolacji kodu 5B-6B sygnau zbiorczego bit 5: ALZUZ-Alarm Zwrotny Z Urzdzenia Zdalnego (ALZUZ=1 - urzdzenie otrzymao sygna alarmu zwrotnego, ALZUZ=0 - brak sygnau alarmu zwrotnego). bit 4: 106K - Przekroczenie stopy 10-6 bdw kodowych w odebranym sygnale zbiorczym (E10_6=1 - nastpio przekroczenie, E10_6=0 - przekroczenie nie nastpio). bit 3: 103K - Przekroczenie stopy 10-3 bdw kodowych w odebranym sygnale zbiorczym (E10_3=1 - nastpio przekroczenie, E10_3=0 - przekroczenie nie nastpio). bit 2: USR - Utrata Synchronizacji Ramki bit 1: ZMN - Zanik Mocy Nadajnika (0 moc poprawna, 1 moc niepoprawna) bit 0: ZSO - Zanik Sygnau Optycznego na wejciu wiatowodowym |
| INT statSUS | 1.3.6.1.4.1.5746.1.2.3.6 | INTEGER | read-only | Stan rejestru Status Ukladu Sygnalizacji Bity sygnalizacji alarmw: bit 0: DALP - bit sygnalizacji alarmu pilnego lub zaniku alarmu po potwierdzeniu bit 1: DPALP - bit sygnalizacji przypomnienia alarmu pilnego bit 2: PALP - bit zaczenia przekanika alarmu pilnego bit 3: DALN - bit sygnalizacji alarmu niepilnego lub zaniku alarmu po potwierdzeniu bit 4: DPALN - bit sygnalizacji przypomnienia alarmu niepilnego bit 5: PALN - bit zaczenia przekanika alarmu niepilnego |
| INT statKJT | 1.3.6.1.4.1.5746.1.2.3.7 | INTEGER | read-only | Stan rejestru Kontrola Jakosci Transmisji Bity rejestru: bit 7: PSES24O - Wystpienie przekroczenia wartoci progowej dla rejestru SES,24 godzinnego, dla kierunku odbiorczego (PSES24O=1 - nastpio przekroczenie, PSES24O=0 - przekroczenie nie nastpio) bit 6: PSES24N - Wstpienie przekroczenia wartoci progowej dla rejestru SES, 24 godzinnego, dla kierunku nadawczego (PSES24N=1 - nastpio przekroczenie, PSES24N=0 - przekroczenie nie nastpio) bit 5: PES24O - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 24 godzinnego, dla kierunku odbiorczego (PES24O=1 - nastpio przekroczenie, PES24O=0 - przekroczenie nie nastpio) bit 4: PES24N - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 24 godzinnego, dla kierunku nadawczego (PES24N=1 - nastpio przekroczenie, PES24N=0 - przekroczenie nie nastpio) bit 3: PSES15O - Wystpienie przekroczenia wartoci progowej dla rejestru SES, 15 minutowego, dla kierunku odbiorczego (PSES15O=1 - nastpio przekroczenie, PSES15O=0 - przekroczenie nie nastpio) bit 2: PSES15N - Wystpienie przekroczenia wartoci progowej dla rejestru SES, 15 minutowego, dla kierunku nadawczego (PSES15N=1 - nastpio przekroczenie, PSES15N=0 - przekroczenie nie nastpio) bit 1: PES15O - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 15 minutowego, dla kierunku odbiorczego (PES15O=1 - nastpio przekroczenie, PES15O=0 - przekroczenie nie nastpio) bit 0: PES15N - Wystpienie przekroczenia wartoci progowej dla rejestru ES, 15 minutowego, dla kierunku nadawczego (PES15N=1 - nastpio przekroczenie, PES15N=0 - przekroczenie nie nastpio) |
| HUN statTemperature | 1.3.6.1.4.1.5746.1.2.3.8 | Hundredths | read-only | Temperatura otoczenia systemu (warto np. 2758 oznacza temperatur 27.58 stopni C) |
| INT stat3VVoltage | 1.3.6.1.4.1.5746.1.2.3.9 | INTEGER | read-only | Napiecie zasilania 3.3V (warto np. 327 oznacza napicie 3.27 V) |
| INT stat5VVoltage | 1.3.6.1.4.1.5746.1.2.3.10 | INTEGER | read-only | Napiecie zasilania 5V (warto np. 527 oznacza napicie 5.27 V) |
| INT statExtremLevel | 1.3.6.1.4.1.5746.1.2.3.13 | INTEGER | read-only | Stan napi zasilajcych i temperatury otoczenia. Poszczeglne bity oznaczaj przekroczenie wartoci dopuszczalnej (progowej): (1 - przekroczenie wartosci progowej, 0 - wrtosc ponizej ustawionego progu) bit 0: stan napicia 3.3V bit 1: stan napicia 5V bit 7: stan temperatury otoczenia |
| INT statLOESmask | 1.3.6.1.4.1.5746.1.2.3.14 | INTEGER | read-only | Maska rejestru Sygnalow skladowych 1-16 |
| INT statBZSTATmask | 1.3.6.1.4.1.5746.1.2.3.15 | INTEGER | read-only | Maska rejestru Status Bloku Zbiorczego |
| INT statAISE3 | 1.3.6.1.4.1.5746.1.2.3.16 | INTEGER | read-only | Sygnal AIS w module E3 |
| eventLog | 1.3.6.1.4.1.5746.1.2.4 | |||
| INT logIndexLastEvent | 1.3.6.1.4.1.5746.1.2.4.1 | INTEGER | read-only | Indeks do ostatnio wpisanego zdarzenia w historii dziennika zdarzen. -1 oznacza dziennik pusty |
| INT logErase | 1.3.6.1.4.1.5746.1.2.4.2 | INTEGER | read-write | Kasowanie dziennika zdarzen ustawienie. 1 - kasowanie |
| logTable | 1.3.6.1.4.1.5746.1.2.4.3 | not-accessible | Tabela opisuje dziennik zdarzen | |
| logEntry | 1.3.6.1.4.1.5746.1.2.4.3.1 | not-accessible | ||
| INT logIndex | 1.3.6.1.4.1.5746.1.2.4.3.1.1 | INTEGER | read-only | Indeks zdarzenia |
| STR logEventDescription | 1.3.6.1.4.1.5746.1.2.4.3.1.2 | DisplayString | read-only | Opis Zdarzenia: YYYY/MM/DD HH:MM.SS ZZZ YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta SS - sekunda ZZZ - identyfikator zdarzenia |
| es | 1.3.6.1.4.1.5746.1.2.5 | |||
| INT esLastES15T | 1.3.6.1.4.1.5746.1.2.5.1 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES15N w tablicy licznikow |
| INT esLastES15R | 1.3.6.1.4.1.5746.1.2.5.2 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES15O w tablicy licznikow |
| INT esLastSES15T | 1.3.6.1.4.1.5746.1.2.5.3 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES15N w tablicy licznikow |
| INT esLastSES15R | 1.3.6.1.4.1.5746.1.2.5.4 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES15O w tablicy licznikow |
| INT esLastES24T | 1.3.6.1.4.1.5746.1.2.5.5 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES24N w tablicy licznikow |
| INT esLastES24R | 1.3.6.1.4.1.5746.1.2.5.6 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru ES24O w tablicy licznikow |
| INT esLastSES24T | 1.3.6.1.4.1.5746.1.2.5.7 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES24N w tablicy licznikow |
| INT esLastSES24R | 1.3.6.1.4.1.5746.1.2.5.8 | INTEGER | read-only | Indeks ostatniego zapisanego rejestru SES24O w tablicy licznikow |
| INT esErase | 1.3.6.1.4.1.5746.1.2.5.9 | INTEGER | read-write | Kasowanie rejestrw Es/Ses ustawienie 1 - kasowanie |
| INT esESAlarm | 1.3.6.1.4.1.5746.1.2.5.10 | INTEGER | read-write | Aktywacja alarmu przekroczenia wartoci progowej ES lub SES 0 nieaktywny 1 aktywny |
| INT esES15On | 1.3.6.1.4.1.5746.1.2.5.11 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu niepilnego w okresie 15 min. (0-900) |
| INT esES15Off | 1.3.6.1.4.1.5746.1.2.5.12 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu niepilnego w okresie 15 min. (0-900) |
| INT esSES15On | 1.3.6.1.4.1.5746.1.2.5.13 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu pilnego w okresie 15 min. (0-900) |
| INT esSES15Off | 1.3.6.1.4.1.5746.1.2.5.14 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu pilnego w okresie 15 min. (0-900) |
| INT esES24On | 1.3.6.1.4.1.5746.1.2.5.15 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
| INT esES24Off | 1.3.6.1.4.1.5746.1.2.5.16 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu niepilnego w okresie 24 h. (0-86400) |
| INT esSES24On | 1.3.6.1.4.1.5746.1.2.5.17 | INTEGER | read-write | Wartosc progowa zalaczenia alarmu pilnego w okresie 24 h. (0-86400) |
| INT esSES24Off | 1.3.6.1.4.1.5746.1.2.5.18 | INTEGER | read-write | Wartosc progowa wylaczenia alarmu pilnego w okresie 24 h. (0-86400) |
| INT esESSESHour | 1.3.6.1.4.1.5746.1.2.5.19 | INTEGER | read-write | Godzina rozpoczecia zliczania w rejestrach ES i SES |
| INT esESSESMinute | 1.3.6.1.4.1.5746.1.2.5.20 | INTEGER | read-write | Minuta rozpoczecia zliczania w rejestrach ES i SES |
| esTableES15T | 1.3.6.1.4.1.5746.1.2.5.21 | not-accessible | Tabela opisuje zapis licznikow ES15N | |
| esEntryES15T | 1.3.6.1.4.1.5746.1.2.5.21.1 | not-accessible | ||
| INT esIndexES15T | 1.3.6.1.4.1.5746.1.2.5.21.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES15T | 1.3.6.1.4.1.5746.1.2.5.21.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableES15R | 1.3.6.1.4.1.5746.1.2.5.22 | not-accessible | Tabela opisuje zapis licznika ES15O | |
| esEntryES15R | 1.3.6.1.4.1.5746.1.2.5.22.1 | not-accessible | ||
| INT esIndexES15R | 1.3.6.1.4.1.5746.1.2.5.22.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES15R | 1.3.6.1.4.1.5746.1.2.5.22.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableSES15T | 1.3.6.1.4.1.5746.1.2.5.23 | not-accessible | Tabela opisuje zapis licznika SES15N | |
| esEntrySES15T | 1.3.6.1.4.1.5746.1.2.5.23.1 | not-accessible | ||
| INT esIndexSES15T | 1.3.6.1.4.1.5746.1.2.5.23.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES15T | 1.3.6.1.4.1.5746.1.2.5.23.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableSES15R | 1.3.6.1.4.1.5746.1.2.5.24 | not-accessible | Tabela opisuje zapis licznika SES15O | |
| esEntrySES15R | 1.3.6.1.4.1.5746.1.2.5.24.1 | not-accessible | ||
| INT esIndexSES15R | 1.3.6.1.4.1.5746.1.2.5.24.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES15R | 1.3.6.1.4.1.5746.1.2.5.24.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLL - licznik sekund z bledami |
| esTableES24T | 1.3.6.1.4.1.5746.1.2.5.25 | not-accessible | Tabela opisuje zapis licznika ES24N | |
| esEntryES24T | 1.3.6.1.4.1.5746.1.2.5.25.1 | not-accessible | ||
| INT esIndexES24T | 1.3.6.1.4.1.5746.1.2.5.25.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES24T | 1.3.6.1.4.1.5746.1.2.5.25.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableES24R | 1.3.6.1.4.1.5746.1.2.5.26 | not-accessible | Tabela opisuje zapis licznika ES24O | |
| esEntryES24R | 1.3.6.1.4.1.5746.1.2.5.26.1 | not-accessible | ||
| INT esIndexES24R | 1.3.6.1.4.1.5746.1.2.5.26.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionES24R | 1.3.6.1.4.1.5746.1.2.5.26.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableSES24T | 1.3.6.1.4.1.5746.1.2.5.27 | not-accessible | Tabela opisuje zapis licznika SES24N | |
| esEntrySES24T | 1.3.6.1.4.1.5746.1.2.5.27.1 | not-accessible | ||
| INT esIndexSES24T | 1.3.6.1.4.1.5746.1.2.5.27.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES24T | 1.3.6.1.4.1.5746.1.2.5.27.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| esTableSES24R | 1.3.6.1.4.1.5746.1.2.5.28 | not-accessible | Tabela opisuje zapis licznika SES24O | |
| esEntrySES24R | 1.3.6.1.4.1.5746.1.2.5.28.1 | not-accessible | ||
| INT esIndexSES24R | 1.3.6.1.4.1.5746.1.2.5.28.1.1 | INTEGER | read-only | Indeks |
| STR esEventDescriptionSES24R | 1.3.6.1.4.1.5746.1.2.5.28.1.2 | DisplayString | read-only | Opis: YYYY/MM/DD HH:MM LLLLL A YYYY - rok MM - miesiac DD - dzien HH - godzina MM - minuta LLLLL- licznik sekund z bledami |
| test | 1.3.6.1.4.1.5746.1.2.6 | |||
| INT testTributaryChannelLoopType1 | 1.3.6.1.4.1.5746.1.2.6.1 | INTEGER | read-write | Zalaczenie petli kanalu skladowego 1 - 16 do interfejsu. (ALx = 1 zaczenie ptli, ALx = 0 wyczene ptli na kanale x) bit : 15 14 13 12 11 10 9 8 nazwa : AL16 AL15 AL14 AL13 AL12 AL11 AL10 AL9 bit : 7 6 5 4 3 2 1 0 nazwa : AL8 AL7 AL6 AL5 AL4 AL3 AL2 AL1 |
| INT testTributaryChannelLoopType2 | 1.3.6.1.4.1.5746.1.2.6.2 | INTEGER | read-write | Zalaczenie petli kanalu skladowego 1 - 16 od interfejsu. (RLx = 1 zaczenie ptli, RLx = 0 wyczene ptli na kanale x) bit : 15 14 13 12 11 10 9 8 nazwa : RL16 RL15 RL14 RL13 RL12 RL11 RL10 RL9 bit : 7 6 5 4 3 2 1 0 nazwa : RL8 RL7 RL6 RL5 RL4 RL3 RL2 RL1 |
| INT testMainChannelLoopType1 | 1.3.6.1.4.1.5746.1.2.6.3 | INTEGER | read-write | Zalaczenie petli kanalu zbiorczego do interfejsu |
| INT testMainChannelLoopType2 | 1.3.6.1.4.1.5746.1.2.6.4 | INTEGER | read-write | Zalaczenie petli kanalu zbiorczego od interfejsu |
| INT testGeneratorDetector | 1.3.6.1.4.1.5746.1.2.6.5 | INTEGER | read-write | numer generatora/detektora wykorzystywanego do testu 1..16 - generator w kierunku kanalu skladowego (E1) 1..16 17 - generator w kierunku kanalu zbiorczego (E3) |
| INT testGCT | 1.3.6.1.4.1.5746.1.2.6.6 | INTEGER | read-write | Sterowanie zaczaniem/wyczaniem generatorw testowych wybranych kanaw E1/E3: 1 generator zaczony 0 generator wyczony |
| INT testTime | 1.3.6.1.4.1.5746.1.2.6.7 | INTEGER | read-write | Deklarowany czas trwania testu w sekundach. Maks. 24 godziny |
| INT testSyncTime | 1.3.6.1.4.1.5746.1.2.6.8 | INTEGER | read-only | czas pomiaru gdy jest synchronizacja |
| INT testNoSyncTime | 1.3.6.1.4.1.5746.1.2.6.9 | INTEGER | read-only | czas pomiaru gdy brak synchronizacji |
| I32 testErrorsPerSec | 1.3.6.1.4.1.5746.1.2.6.10 | Integer32 | read-only | Biezaca liczba bledow w cyklu sekundowym |
| I32 testTotalErrorNumber | 1.3.6.1.4.1.5746.1.2.6.11 | Integer32 | read-only | Calkowita liczba bledow |
| STR testBER | 1.3.6.1.4.1.5746.1.2.6.12 | DisplayString | read-write | Stopa bledow w formacie: P.Pe-LL (notacja naukowa) przyklad: 2.3e-09 |
| I32 testErrorsPerSecBWSZ | 1.3.6.1.4.1.5746.1.2.6.13 | Integer32 | read-only | Biezaca liczba bledow BWSZ w cyklu sekundowym |
| I32 testTotalErrorNumberBWSZ | 1.3.6.1.4.1.5746.1.2.6.14 | Integer32 | read-only | Calkowita liczba bledow BWSZ |
| STR testBERBWSZ | 1.3.6.1.4.1.5746.1.2.6.15 | DisplayString | read-write | Stopa bledow BWSZ w formacie: P.Pe-LL (notacja naukowa) przyklad: 2.3e-09 |
| INT testSyncYesNo | 1.3.6.1.4.1.5746.1.2.6.16 | INTEGER | read-only | Flaga synchronizacji (1 oznacza detekcj cigu testowego) |
| INT testStatus | 1.3.6.1.4.1.5746.1.2.6.17 | INTEGER | read-only | status wykonywania testu 0 OFF test wyczony 1 ON test zaczony 2 RUN test trwa 3 READY gotowo do rozpoczcia testu 4 WAIT_ON oczekiwanie na zaczenie testu 5 WAIT_OFF oczekiwanie na wyczenie testu 6 WAIT oczekiwanie |
| optiLine16MIBNotifications | 1.3.6.1.4.1.5746.1.2.7 | |||
| mibNotificationsPrefix | 1.3.6.1.4.1.5746.1.2.7.0 | |||
| NTF trapOptiLine16ALPActive | 1.3.6.1.4.1.5746.1.2.7.0.1 | Aktywny Alarm pilny | ||
| NTF trapOptiLine16ALNActive | 1.3.6.1.4.1.5746.1.2.7.0.2 | Aktywny Alarm niepilny | ||
| NTF trapOptiLine16LogIdn | 1.3.6.1.4.1.5746.1.2.7.0.3 | Wystapienie zdarzenia w urzadzeniu: 1.Zapis do lokalnego dziennika zdarzen 2.Przekazanie identyfikatora zdarzenia w trapie | ||
| NTF trapOptiLine16Es | 1.3.6.1.4.1.5746.1.2.7.0.4 | Zmiana w licznikach es/ses | ||
| NTF trapOptiLine16confn | 1.3.6.1.4.1.5746.1.2.7.0.5 | Zapis do zmiennej z grupy knfiguracja, n - identyfikator elementu, ktory zostal zmodyfikowany | ||
| NTF trapOptiLine16ALPInactive | 1.3.6.1.4.1.5746.1.2.7.0.6 | Nieaktywny Alarm pilny | ||
| NTF trapOptiLine16ALNInactive | 1.3.6.1.4.1.5746.1.2.7.0.7 | Nieaktywny Alarm niepilny | ||
| optiLine16MIBObjects | 1.3.6.1.4.1.5746.1.2.7.1 | |||
| INT obEventIdn | 1.3.6.1.4.1.5746.1.2.7.1.1 | INTEGER | read-only | Nr zdarzenia |
| STR obEventDescription | 1.3.6.1.4.1.5746.1.2.7.1.2 | DisplayString | read-only | Opis zdarzenia |
RFC description
A SNMP Management Information Base module for network management and monitoring. The specific purpose relates to TM63 device management, though exact vendor details are not widely documented in public repositories.
Start monitoring Lanex telecom transmission equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.