testBER
Module: TM62-MIB
OID (symbolic): TM62-MIB::testBER
OID (numeric): 1.3.6.1.4.1.5746.1.1.6.12
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-write
Description: Stopa bledow w formacie: P.Pe-LL (notacja naukowa) przyklad: 2.3e-09
What is testBER?
The measured bit-error rate from the current or last test run, expressed in scientific notation as a string, e.g. "2.3e-09".
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5746.1.1.6.12 snmpwalk -v2c -c public <target> TM62-MIB::testBER
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.5746.1.1.6.12.1 snmpget -v2c -c public <target> TM62-MIB::testBER.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.5746.1.1.6.12.1 s <value>
Start monitoring LANEX telecom/power monitoring unit, TM62 device (firmware version/event-log status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TM62-MIB::testBER OID value, configure state conditions and alerts, and monitor any LANEX telecom/power monitoring unit, TM62 device (firmware version/event-log status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.5746 | lanex | TM62-MIB |
| 1.3.6.1.4.1.5746.1 | telecom | TM62-MIB |
| 1.3.6.1.4.1.5746.1.1 | optiLine4 | TM62-MIB |
| 1.3.6.1.4.1.5746.1.1.6 | test | TM62-MIB |
| 1.3.6.1.4.1.5746.1.1.6.12 | testBER | TM62-MIB |