TIMETRA-IEEE8021-CFM-MIB :: tmnxDot1agCfmMepEthAisTxCount

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TIMETRA-IEEE8021-CFM-MIB › tmnxDot1agCfmMepEthAisTxCount

tmnxDot1agCfmMepEthAisTxCount

Module: TIMETRA-IEEE8021-CFM-MIB

OID (symbolic): TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepEthAisTxCount

OID (numeric): 1.3.6.1.4.1.6527.3.1.2.52.7.1.1.10

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The value of tmnxDot1agCfmMepEthAisTxCount indicates number of AIS frames transmitted on the MEP.

What is tmnxDot1agCfmMepEthAisTxCount?

This counter tracks the number of AIS frames this MEP has transmitted. An admin monitors this to confirm AIS is actively firing as expected during a known fault condition, and to see how long an AIS condition has been ongoing based on how much the counter has incremented. A steadily incrementing count with no corresponding known fault is worth investigating, since it means this MEP believes a lower-layer fault is ongoing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.52.7.1.1.10
snmpwalk -v2c -c public <target> TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepEthAisTxCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6527.3.1.2.52.7.1.1.10.1
snmpget -v2c -c public <target> TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepEthAisTxCount.1

Start monitoring Alcatel-Lucent (Nokia) SROS service routers and switches (802.1ag CFM MEP/SDP binding status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepEthAisTxCount OID value, configure state conditions and alerts, and monitor any Alcatel-Lucent (Nokia) SROS service routers and switches (802.1ag CFM MEP/SDP binding status) from a single console.

How to Use in IPNetwork Monitor

Select an Alcatel-Lucent (Nokia) SROS service routers and switch (802.1ag CFM MEP/SDP binding status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tmnxDot1agCfmMepEthAisTxCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The value of tmnxDot1agCfmMepEthAisTxCount indicates number of AIS frames transmitted on the MEP. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6527timetraALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3timetraProductsALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1tmnxSRMIBALCATEL-IND1-TIMETRA-GLOBAL-MIB
1.3.6.1.4.1.6527.3.1.2tmnxSRObjsALCATEL-IND1-TIMETRA-GLOBAL-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6527.3.1.2.52tmnxDot1agMIBObjsTIMETRA-IEEE8021-CFM-MIB
1.3.6.1.4.1.6527.3.1.2.52.7tmnxDot1agCfmMepTIMETRA-IEEE8021-CFM-MIB
1.3.6.1.4.1.6527.3.1.2.52.7.1tmnxDot1agCfmMepTableTIMETRA-IEEE8021-CFM-MIB
1.3.6.1.4.1.6527.3.1.2.52.7.1.1tmnxDot1agCfmMepEntryTIMETRA-IEEE8021-CFM-MIB
1.3.6.1.4.1.6527.3.1.2.52.7.1.1.10tmnxDot1agCfmMepEthAisTxCountTIMETRA-IEEE8021-CFM-MIB