All MIBs › TELESTE-COMMON-MIB
Category: Broadcast and Cable TV Equipment
Description: Manages common objects shared across Teleste cable TV headend equipment, including system identity and alarm summary.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is TELESTE-COMMON-MIB?
TELESTE-COMMON-MIB is a common enterprise MIB module shared across Teleste's cable TV headend and broadband access equipment, providing shared identity and alarm definitions used by other Teleste product-specific MIBs. It exposes system identity objects (such as device/product identification) and a summarized alarm status object aggregating fault conditions across the equipment. Its monitoring value lies in giving a quick top-level view of device health and identity, letting an operator confirm which unit is being managed and whether it currently has any active alarm condition, which is foundational for headend fault management. As a "common" MIB it is explicitly designed to be imported and extended by other Teleste equipment-specific MIB modules rather than used standalone. It is typically deployed in cable/broadband headend network management systems monitoring a fleet of Teleste optical or RF equipment. Engineers can download the TELESTE-COMMON-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in TELESTE-COMMON-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Teleste cable TV/broadband headend equipment
Monitoring Examples
An operator would poll the system identity objects to confirm device model/identity and check the alarm summary object to see at a glance whether any fault condition is currently active on a given headend unit, before drilling into a product-specific Teleste MIB for detail. No sample object names were available in the source excerpt, so this description is based on the stated short description of shared identity and alarm summary objects.
What Can Be Monitored
- device/system identity
- aggregate alarm/fault status
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| Counter | |
| IpAddress |
From RFC1213-MIB
| DisplayString |
From TELESTE-ROOT-MIB
| DateAndTime | |
| TPhysAddress | |
| Uint16 | |
| common | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| element | 1.3.6.1.4.1.3715.99.1 | |||
| elementInformation | 1.3.6.1.4.1.3715.99.1.1 | |||
| STR elementName | 1.3.6.1.4.1.3715.99.1.1.1 | DisplayString | read-write | This is the logical name of the controlling module of the network element. The name may or may not be the same as the module's name in the moduleTable. |
| INT elementStructure | 1.3.6.1.4.1.3715.99.1.1.2 | INTEGER | read-only | This object tells whether the device is a single compact device or a modular device. |
| INT elementConfigChangeCode | 1.3.6.1.4.1.3715.99.1.1.3 | INTEGER | read-only | This object is an indicator about changes in the network element configuration. How the value is formed is device dependent. It can be a counter, a checksum of the device configuration parameters, a DateAndTime type variable or even SysUptime, if no other information is available. DateAndTime is the recommended value. This object is intended to permit a management application to maintain configuration (including moduleTable) syncronization with the agent. |
| INT elementResetCount | 1.3.6.1.4.1.3715.99.1.1.4 | INTEGER | read-only | Total number of software resets during the device's life time. |
| INT elementTotalUpTime | 1.3.6.1.4.1.3715.99.1.1.5 | INTEGER | read-only | The total uptime the device (software) has been running. Unit 1 day. |
| INT elementLatitude | 1.3.6.1.4.1.3715.99.1.1.6 | INTEGER | read-write | Device latitude coordinate. Unit 0.00001 degrees. |
| INT elementLongitude | 1.3.6.1.4.1.3715.99.1.1.7 | INTEGER | read-write | Device longitude coordinate. Unit 0.00001 degrees. |
| INT elementAltitude | 1.3.6.1.4.1.3715.99.1.1.8 | INTEGER | read-write | Device altitude coordinate. Unit 1 metre. |
| elementStatus | 1.3.6.1.4.1.3715.99.1.2 | |||
| INT statusGeneral | 1.3.6.1.4.1.3715.99.1.2.1 | INTEGER | read-only | A number stating the general status of the element. Values: 1 = Normal 2 = At least one Notification is active 3 = At least one Warning is active 4 = At least one Alarm is active If the element has more than one state active, then the state with the highest value is returned. |
| INT statusBusMaster | 1.3.6.1.4.1.3715.99.1.2.2 | INTEGER | read-only | A number stating the Bus Master status of the NE. Values: 1 = The NE is a slave-only device 2 = The NE is configured as slave 3 = The NE is configured as master but is currently slave because a stronger master is on the bus 4 = The NE is currently the bus master |
| INT statusLmt | 1.3.6.1.4.1.3715.99.1.2.3 | INTEGER | read-only | A number telling if the Local Management Terminal (LMT) is connected to the element. Values: 1 = The element does not have an LMT interface 2 = The element can not detect if an LMT is connected 3 = The element has not detected a connected LMT 4 = The element has detected a connected LMT Note! Applies only to fysically point-to-point connected LMT's to device, not via bus ot other shared medias. |
| INT statusLid | 1.3.6.1.4.1.3715.99.1.2.4 | INTEGER | read-only | Element lid status: 1 = no lid (no lid sensor is available) 2 = lid is closed 3 = lid is open |
| INT statusTemperature | 1.3.6.1.4.1.3715.99.1.2.5 | INTEGER | read-only | Element temperature status: 1 = normal 2 = HIHI 3 = Hi 4 = Lo 5 = LOLO |
| INT statusFan | 1.3.6.1.4.1.3715.99.1.2.6 | INTEGER | read-only | A common status object for all fans in the device. fanNormal(1) = all fans operate normally fanFailure(2) = at least one fan has a failure |
| INT statusHardware | 1.3.6.1.4.1.3715.99.1.2.7 | INTEGER | read-only | Device hardware status: hwNormal(1) = the hardware operates normally hwFailure(2) = a hardware failure is detected |
| INT statusSoftware | 1.3.6.1.4.1.3715.99.1.2.8 | INTEGER | read-only | Device software status: swNormal(1) = the software operates normally swFailure(2) = a software failure is detected swMissing(3) = the software or firmware is missing sw(Initialising(4) = the software is initialising |
| INT statusSettings | 1.3.6.1.4.1.3715.99.1.2.9 | INTEGER | read-only | Status of device settings: settingsStable(1) = settings are stable settingsChanged(2) = settings have been (recently) changed settingsNotAvailable(3) = settings status is not available The value should stay in value 2 only a predefined time, e.g. 60 seconds or the time it takes until the settings are written into non-volatile memory. |
| elementControl | 1.3.6.1.4.1.3715.99.1.3 | |||
| INT controlResetElement | 1.3.6.1.4.1.3715.99.1.3.1 | INTEGER | read-write | On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned. |
| INT controlBusMasterAdminState | 1.3.6.1.4.1.3715.99.1.3.2 | INTEGER | read-write | This object tells whether the element is configured as a bus master or not. Only relevant for bus master type of elements. Others return no(2). |
| INT controlAlarmDetection | 1.3.6.1.4.1.3715.99.1.3.3 | INTEGER | read-write | This variable is used to disable or enable the element alarm checking. When disabled(1), the element will not check any alarms (or send traps). Default value is enabled(2). Note: This variable must be consistent with commonAlarmDetectionControl in SCTE-HMS-COMMON-MIB, if that is implemented. |
| INT controlMaxNumberTrapReceivers | 1.3.6.1.4.1.3715.99.1.3.4 | INTEGER | read-only | Number of entries in the elementTrapReceiverTable. At least one trap entry must be supported. |
| controlTrapReceiverTable | 1.3.6.1.4.1.3715.99.1.3.5 | not-accessible | A table of manager trap receiver addresses, ports and communities. Total number of entries can not exceed elementNumberTrapReceivers. An entry is deleted from this table by setting its IP address to '0.0.0.0'. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented. | |
| controlTrapReceiverEntry | 1.3.6.1.4.1.3715.99.1.3.5.1 | not-accessible | ||
| INT receiverEntryId | 1.3.6.1.4.1.3715.99.1.3.5.1.1 | INTEGER | read-only | Unique table index. Makes possible to have several ip-address of 0.0.0.0 entries so that no mechanism for row manipulation of table is needed. |
| IP receiverAddress | 1.3.6.1.4.1.3715.99.1.3.5.1.2 | IpAddress | read-write | Ip address of the manager receiving Traps. |
| INT receiverPort | 1.3.6.1.4.1.3715.99.1.3.5.1.3 | INTEGER | read-write | Trap UDP port number. Default port is the standard trap port 162. |
| STR receiverCommunity | 1.3.6.1.4.1.3715.99.1.3.5.1.4 | DisplayString | read-write | Community string for the trap receiver. The agent is allowed to limit the length of the string. Minimum length of eight characters must be supported. Note: one of the community strings must match to commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if that is implemented. |
| INT controlTrapSending | 1.3.6.1.4.1.3715.99.1.3.6 | INTEGER | read-write | Enables/disables trap sending. 1 = traps enabled 2 = traps disabled |
| INT controlTrapInterval | 1.3.6.1.4.1.3715.99.1.3.7 | INTEGER | read-write | The minimum interval between traps. - Unit 10 milliseconds - Minimum value 0 (send as fast as possible) - Maximum value 1000 (10 seconds) - Default value is 100 (1 second) |
| INT controlTrapLifeTime | 1.3.6.1.4.1.3715.99.1.3.8 | INTEGER | read-write | The maximum time a trap stays in the trap queue waiting for sending. - Unit 1 second. - Minimum value 10 - Maximum value 300 - Default value 60 |
| INT controlAlarmOnDelay | 1.3.6.1.4.1.3715.99.1.3.9 | INTEGER | read-write | The minimum time an object's alarm/warning condition must exist before it is recorded as an alarm/warning. Common to all alarms/warnings - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 100 (1 second) |
| INT controlAlarmOffDelay | 1.3.6.1.4.1.3715.99.1.3.10 | INTEGER | read-write | The minimum time an alarm/warning entry stays active after the object has reached it's normal condition. Common to all alarms/warnings. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - default value 100 (1 second) |
| INT controlTrapDelay | 1.3.6.1.4.1.3715.99.1.3.11 | INTEGER | read-write | The time before a trap is sent after an alarm is detected. - Unit 10 ms - Minimum value 10 (100 ms) - Maximum value 6000 (60 seconds) - Default value 500 (5 seconds) This parameter can be used to control alarm storms e.g. in an amplifier cascade by using a different value in each amplifier. |
| elementProductKey | 1.3.6.1.4.1.3715.99.1.4 | |||
| INT productKeyNumberOfKeys | 1.3.6.1.4.1.3715.99.1.4.4 | INTEGER | read-only | Number of product keys supported by the device. |
| productKeyTable | 1.3.6.1.4.1.3715.99.1.4.5 | not-accessible | ||
| productKeyEntry | 1.3.6.1.4.1.3715.99.1.4.5.1 | not-accessible | ||
| INT productKeyIndex | 1.3.6.1.4.1.3715.99.1.4.5.1.1 | INTEGER | read-only | Product key index. |
| OCT productKeyValue | 1.3.6.1.4.1.3715.99.1.4.5.1.2 | OCTET STRING | read-write | Product key value. |
| OCT productKeyMask | 1.3.6.1.4.1.3715.99.1.4.5.1.3 | OCTET STRING | read-only | Product key mask. |
| INT productKeyStatus | 1.3.6.1.4.1.3715.99.1.4.5.1.4 | INTEGER | read-only | Product key status: 1(keyInvalid) = the key is invalid or missing 2(keyValid) = the key is valid |
| INT productKeyCipher | 1.3.6.1.4.1.3715.99.1.4.5.1.5 | INTEGER | read-only | Cipher method supported by this key: 1(cipherOther) = other ciphering is used 2(cipherBlowFish) = BlowFish ciphering is used 3(cipherXXTEA) = XXTEA ciphering is used |
| INT productKeyNumberOfFeatures | 1.3.6.1.4.1.3715.99.1.4.5.1.6 | INTEGER | read-only | Number of features available with this key. |
| productKeyFeatureTable | 1.3.6.1.4.1.3715.99.1.4.6 | not-accessible | ||
| productKeyFeatureEntry | 1.3.6.1.4.1.3715.99.1.4.6.1 | not-accessible | ||
| INT productKeyFeatureIndex | 1.3.6.1.4.1.3715.99.1.4.6.1.1 | INTEGER | read-only | Feature index (second index). |
| OCT productKeyFeatureName | 1.3.6.1.4.1.3715.99.1.4.6.1.2 | OCTET STRING | read-only | A human-readable description of the feature. |
| INT productKeyFeatureEnable | 1.3.6.1.4.1.3715.99.1.4.6.1.3 | INTEGER | read-only | Status of the feature: 1(featureDisable) = the feature si disabled in this device 2(featureEnable) = the feature is enabled in this devices |
| INT productKeyFeatureExpirationTime | 1.3.6.1.4.1.3715.99.1.4.6.1.4 | INTEGER | read-only | Number of days left before the feature expires. A zero value means infinite validity time. This object has a meaning only if the feature is enabled (productKeyFeatureEnable = 2(featureEnable)). |
| moduleInformation | 1.3.6.1.4.1.3715.99.2.1 | |||
| moduleTable | 1.3.6.1.4.1.3715.99.2.1.1 | not-accessible | This table lists basic module identification and configuration data of modules installed inside the managed element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table. Object moduleId is used for indexing the modules in all module section tables. | |
| moduleEntry | 1.3.6.1.4.1.3715.99.2.1.1.1 | not-accessible | ||
| INT moduleId | 1.3.6.1.4.1.3715.99.2.1.1.1.1 | INTEGER | read-only | An unique module index identifying the (physical) modules inside the network element. The exact conjunction between the index and the physical modules depends on the element structural principle. For network elements containing plug-in modules the index should follow module slot numbering. This index should be used in all subsequent module tables. |
| STR moduleName | 1.3.6.1.4.1.3715.99.2.1.1.1.2 | DisplayString | read-write | The identification name ('aliasname') of the module. |
| STR moduleHwType | 1.3.6.1.4.1.3715.99.2.1.1.1.3 | DisplayString | read-only | The hardware type name of the module. |
| INT moduleRackNo | 1.3.6.1.4.1.3715.99.2.1.1.1.4 | INTEGER | read-write | Rack number of the module. This can be used to identify the physical position of the module in the case where the agent manages modules that are in several racks. |
| INT moduleSlotNo | 1.3.6.1.4.1.3715.99.2.1.1.1.5 | INTEGER | read-write | Slot number of the module (within rack). |
| moduleDetailTable | 1.3.6.1.4.1.3715.99.2.1.2 | not-accessible | This table lists detailed module data of modules installed inside the element. The first row in the table list information about the element itself. If the element is not modular, only the first row exists in the table. | |
| moduleDetailEntry | 1.3.6.1.4.1.3715.99.2.1.2.1 | not-accessible | ||
| ADR moduleMacAddress | 1.3.6.1.4.1.3715.99.2.1.2.1.1 | TPhysAddress | read-only | Module MAC address. If the MAC address is unknown '00.00.00.00.00.00' is returned. |
| INT moduleBusAddress | 1.3.6.1.4.1.3715.99.2.1.2.1.2 | INTEGER | read-only | Module bus address. |
| DAT moduleAppDate | 1.3.6.1.4.1.3715.99.2.1.2.1.3 | DateAndTime | read-only | Module application software date. |
| STR moduleAppVersion | 1.3.6.1.4.1.3715.99.2.1.2.1.4 | DisplayString | read-only | Module application software version. If software version is undefined, then zero length string is returned. |
| DAT moduleBiosDate | 1.3.6.1.4.1.3715.99.2.1.2.1.5 | DateAndTime | read-only | Module BIOS date. |
| STR moduleBiosVersion | 1.3.6.1.4.1.3715.99.2.1.2.1.6 | DisplayString | read-only | Module BIOS version. If bios version is undefined, a zero length string is returned. |
| STR moduleHwSerialNumber | 1.3.6.1.4.1.3715.99.2.1.2.1.7 | DisplayString | read-only | Module serial number. |
| STR moduleHwVersion | 1.3.6.1.4.1.3715.99.2.1.2.1.8 | DisplayString | read-only | Module hardware version. |
| moduleStatus | 1.3.6.1.4.1.3715.99.2.2 | |||
| moduleStatusTable | 1.3.6.1.4.1.3715.99.2.2.1 | not-accessible | This table contains status objects for modules inside the network element.The first row in the table lists information about the host module. If the element is not modular, only the first row exists in the table. | |
| moduleStatusEntry | 1.3.6.1.4.1.3715.99.2.2.1.1 | not-accessible | Row in moduleStatusTable. The index is moduleId from the moduleTable. Row in this table exist only if there is a row with the same moduleId in the moduleTable. | |
| INT statusResetCause | 1.3.6.1.4.1.3715.99.2.2.1.1.1 | INTEGER | read-only | Reason for the last reset. If the reason is unknown, the value is reasonUnknown(1). If the device makes self reset and it can detect it, then value is reasonSelfReset(2). If the reset was made by the user from the power switch and it can be sensed, then the value is reasonPowerReset(3). If the reason is an external command from the user interface or from the network message (e.g. commonReset), then the reason is reasonCommandedReset(4). |
| INT statusRunningSwImage | 1.3.6.1.4.1.3715.99.2.2.1.1.2 | INTEGER | read-only | Currently running software image number. Bios is 0, applications are numbered from 1..n, where n is the maximum image number. |
| INT statusInternalTemperature | 1.3.6.1.4.1.3715.99.2.2.1.1.3 | INTEGER | read-only | Device temperature, unit 0.1 deg C. Value is zero (0), if temperature is not available. |
| INT statusLidStatus | 1.3.6.1.4.1.3715.99.2.2.1.1.4 | INTEGER | read-only | Current lid status detected by the device. May or may not be the same variable as the elementLidStatus. |
| CTR statusRestartCounter | 1.3.6.1.4.1.3715.99.2.2.1.1.5 | Counter | read-only | This objects counts the number of restarts of the module. A start can be a cold start or a warm start. |
| moduleControl | 1.3.6.1.4.1.3715.99.2.3 | |||
| moduleControlTable | 1.3.6.1.4.1.3715.99.2.3.1 | not-accessible | This table contains common control commands for all the modules inside the element. | |
| moduleControlEntry | 1.3.6.1.4.1.3715.99.2.3.1.1 | not-accessible | ||
| INT controlLedUsage | 1.3.6.1.4.1.3715.99.2.3.1.1.1 | INTEGER | read-write | A variable to instruct how device LED's behave when the lid is closed. |
| INT controlMarkState | 1.3.6.1.4.1.3715.99.2.3.1.1.2 | INTEGER | read-write | A variable to instruct the device to start and stop showing mark (blinking module LED). On read requests returns the current mark state. |
| INT controlReset | 1.3.6.1.4.1.3715.99.2.3.1.1.3 | INTEGER | read-write | On write requests this object commands the module to reset itself. If softReset(3) or hardReset(2) can not be performed, then BAD VALUE error is returned. On read requests value noReset(1) is returned. |
| INT controlTempLimitHiHi | 1.3.6.1.4.1.3715.99.2.3.1.1.4 | INTEGER | read-write | Module temperature HiHi (high alarm) limit in 0.1 degC. |
| INT controlTempLimitHi | 1.3.6.1.4.1.3715.99.2.3.1.1.5 | INTEGER | read-write | Module temperature Hi (high warning) limit in 0.1 degC. |
| INT controlTempLimitLo | 1.3.6.1.4.1.3715.99.2.3.1.1.7 | INTEGER | read-write | Module temperature Lo (low warning) limit in 0.1 degC. |
| INT controlTempLimitLoLo | 1.3.6.1.4.1.3715.99.2.3.1.1.8 | INTEGER | read-write | Module temperature LoLo (low alarm) limit in 0.1 degC. |
| INT controlTempDeadBand | 1.3.6.1.4.1.3715.99.2.3.1.1.9 | INTEGER | read-write | Module temperature alarm/warning deadband in 0.1 degC. Common to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines the difference between the 'ON' limit and the 'OFF' limit of the corresponding alarm. Example: The Hi limit is 65 degC and the deadband is 5 degC. The high warning is activated when the temperature exceeds 65 degC and deactivated only after it falls below 60 degC. |
| INT controlInternalAppAccess | 1.3.6.1.4.1.3715.99.2.3.1.1.10 | INTEGER | read-write | This object defines whether the internal controller application is able to access the module parameters. This corresponds to the BXX module setting 'Allow Functions'. 1 = allow internal control 2 = deny internal control (remote control is possible) |
| INT controlLocalAccess | 1.3.6.1.4.1.3715.99.2.3.1.1.11 | INTEGER | read-write | This object defines whether the local user interface (buttons, knobs etc.) is enabled or disabled. Values: 1 = disabled, local UI is locked 2 = enabled, local UI is active For modules/devices with no local UI this objects should return value 'disabled (1). |
| moduleSWUpdateTable | 1.3.6.1.4.1.3715.99.2.3.2 | not-accessible | A table of software update control objects. | |
| moduleSWUpdateEntry | 1.3.6.1.4.1.3715.99.2.3.2.1 | not-accessible | ||
| INT sWUpdateControl | 1.3.6.1.4.1.3715.99.2.3.2.1.1 | INTEGER | read-write | Writing value updateStart(4) commands the module to run a software update. The software image location and file name are specified in sWUpdateURL and sWUpdateFilename. Writing a updateIdle(1) when the update is running will terminate the update process immediately. Writing any value when no update is runnign has no effect. Reading this object returns either updateIdle(1), updateRunning(2) or updateFailed(3) depending on the status of the (last) software update. |
| STR swUpdateURL | 1.3.6.1.4.1.3715.99.2.3.2.1.2 | DisplayString | read-write | The URL where the software image can be downloaded. Format e.g. TFTP:\\downloads\swupdate\. |
| STR sWUpdateFileName | 1.3.6.1.4.1.3715.99.2.3.2.1.3 | DisplayString | read-write | File name of the software image file to be downloaded. |
| STR sWUpdateStatus | 1.3.6.1.4.1.3715.99.2.3.2.1.4 | DisplayString | read-only | Description of the software update result. After successful update this object should return a string 'Software updated successfully on '. If the update failed the returned value should be 'Software update failed'. |
| moduleRegistry | 1.3.6.1.4.1.3715.99.2.4 | |||
| moduleSizeOfTable | 1.3.6.1.4.1.3715.99.2.4.1 | not-accessible | This table defines maximum number of entries in the registry tables. All the registry tables have fixed size defined in this table. | |
| moduleSizeOfEntry | 1.3.6.1.4.1.3715.99.2.4.1.1 | not-accessible | ||
| INT sizeOfRegistry | 1.3.6.1.4.1.3715.99.2.4.1.1.1 | INTEGER | read-only | Max number of entries in the registryTable. The entries in the registryTable are numbered from 1..sizeofRegistry. |
| INT sizeOfRepairlog | 1.3.6.1.4.1.3715.99.2.4.1.1.2 | INTEGER | read-only | Max number of entries in the repairlogTable. First entry (oldest entry) is deleted, when a new entry is added and the table is full. |
| INT sizeOfNotebook | 1.3.6.1.4.1.3715.99.2.4.1.1.3 | INTEGER | read-only | Max number of entries in the notebookTable. The lines in the notebookTable are numbered from 1..sizeofNotebook. |
| moduleRegistryTable | 1.3.6.1.4.1.3715.99.2.4.2 | not-accessible | This table lists user data for all modules installed inside the element. Table is indexed by the moduleId and regIndex. regIndex can have values 1..sizeofRegistry. A registryEntry is 'deleted' by setting its name to an empty string. | |
| moduleRegistryEntry | 1.3.6.1.4.1.3715.99.2.4.2.1 | not-accessible | ||
| INT regIndex | 1.3.6.1.4.1.3715.99.2.4.2.1.1 | INTEGER | read-only | A second index to registryTable. Can have values 1..sizeofRegistryTable. |
| STR regName | 1.3.6.1.4.1.3715.99.2.4.2.1.2 | DisplayString | read-write | Descriptive name for the parameter. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. Writing empty string to this object removes it from the registryTable. |
| STR regValue | 1.3.6.1.4.1.3715.99.2.4.2.1.3 | DisplayString | read-write | Textual information describing the parameter information. The agent is allowed to limit the length of the name. Minimum length of eight characters must be supported. |
| moduleRepairLogTable | 1.3.6.1.4.1.3715.99.2.4.3 | not-accessible | This table contains repair history entries for modules in the element. The table is indexed with moduleId and repairLogDate. The table can have sizeofRepairlog number of entries. If this number is exceeded when writing a new entry, the oldest entry is deleted and and a new entry is added. | |
| moduleRepairLogEntry | 1.3.6.1.4.1.3715.99.2.4.3.1 | not-accessible | Row entry in RepairLogTable. Note that it uses double index: moduleId repairIndex. that uniquely identify each log entry. Rows for particular module exist only if there is row, that represents this module in the moduleTable. A row is 'deleted' by giving a date 0000-00-00. | |
| INT repairIndex | 1.3.6.1.4.1.3715.99.2.4.3.1.1 | INTEGER | read-only | Row number of the Repairlog entry. Can have values between 1..sizeOfRepairlog. This field is a second index to moduleRepairLogTable. |
| STR repairDate | 1.3.6.1.4.1.3715.99.2.4.3.1.2 | DisplayString | read-write | Date of this repair entry formatted as CCYY-MM-DD. |
| OCT repairReasonCode | 1.3.6.1.4.1.3715.99.2.4.3.1.3 | OCTET STRING | read-write | Repair code for this entry. |
| OCT repairNameCode | 1.3.6.1.4.1.3715.99.2.4.3.1.4 | OCTET STRING | read-write | Repairer name code (initials) for this entry. |
| STR repairComment | 1.3.6.1.4.1.3715.99.2.4.3.1.5 | DisplayString | read-write | Comment of the repair event. The agent is allowed to truncate the length of the comment, if it is too long to internal storage. |
| moduleNotebookTable | 1.3.6.1.4.1.3715.99.2.4.4 | not-accessible | Notebook is a free text area for manager or serviceman notes. It is divided into 50 character long character blocks or lines. Each line is an entry in the notebookTable. Indices are moduleName and lineNumber. A new line with the same lineNumber overwrites the old line. | |
| moduleNotebookEntry | 1.3.6.1.4.1.3715.99.2.4.4.1 | not-accessible | ||
| INT notebookLineNumber | 1.3.6.1.4.1.3715.99.2.4.4.1.1 | INTEGER | read-only | The line number of the notebookTextLine. The number must be in between 1..sizeofNotebook. inclusive. Numbers should be used consecutively. |
| OCT notebookLineText | 1.3.6.1.4.1.3715.99.2.4.4.1.2 | OCTET STRING | read-write | Text field for storing notes about the module. |
RFC description
Provides common system management objects for all Teleste products including hardware status and firmware.
Start monitoring Teleste cable TV/broadband headend equipment (shared identity/aggregated alarm status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.