All MIBs › T11-FC-SP-SA-MIB › t11FcSpSaPairTerminate
t11FcSpSaPairTerminate
Module: T11-FC-SP-SA-MIB
OID (symbolic): T11-FC-SP-SA-MIB::t11FcSpSaPairTerminate
OID (numeric): 1.3.6.1.2.1.179.1.3.1.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Setting this object to 'terminate' is a request to terminate this pair of Security Associations.
When read, the value of this object is always 'noop'. Setting this object to 'noop' has no effect.
What is t11FcSpSaPairTerminate?
A write-only-style control: setting it to terminate(2) tears down this specific bidirectional SA pair, forcing renegotiation. It always reads back as noop(1), and writing noop has no effect - useful when an admin needs to kill one problematic SA without disrupting all SAs on the interface.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.179.1.3.1.1.8 snmpwalk -v2c -c public <target> T11-FC-SP-SA-MIB::t11FcSpSaPairTerminate
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.179.1.3.1.1.8.1 snmpget -v2c -c public <target> T11-FC-SP-SA-MIB::t11FcSpSaPairTerminate.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.179.1.3.1.1.8.1 i <value>
Start monitoring vendor-neutral, standards-based MIB (INCITS T11 FC-SP), Fibre Channel switches/directors (security-association/cryptographic capability status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the T11-FC-SP-SA-MIB::t11FcSpSaPairTerminate OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB (INCITS T11 FC-SP), Fibre Channel switches/directors (security-association/cryptographic capability status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.179 | t11FcSpSaMIB | T11-FC-SP-SA-MIB |
| 1.3.6.1.2.1.179.1 | t11FcSpSaMIBObjects | T11-FC-SP-SA-MIB |
| 1.3.6.1.2.1.179.1.3 | t11FcSpSaActive | T11-FC-SP-SA-MIB |
| 1.3.6.1.2.1.179.1.3.1 | t11FcSpSaPairTable | T11-FC-SP-SA-MIB |
| 1.3.6.1.2.1.179.1.3.1.1 | t11FcSpSaPairEntry | T11-FC-SP-SA-MIB |
| 1.3.6.1.2.1.179.1.3.1.1.8 | t11FcSpSaPairTerminate | T11-FC-SP-SA-MIB |