All MIBs › T0510-MIB
Category: Vendor-Specific Device Management, WAN and Serial Interfaces
Description:
Manages T0510 device configuration, operational state, and interface parameters.
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC1155-SMI
| enterprises |
What Is T0510-MIB?
T0510-MIB is a vendor MIB from COMET System for its T0510-series network temperature (and humidity) monitoring sensor, a compact SNMP-enabled environmental probe. It exposes current temperature readings alongside configured low/high alarm thresholds, hysteresis settings, and last-reading timestamps, with an "i" (internal) suffix variant covering a second, internal probe channel including humidity. Its entire purpose is hardware environmental status monitoring: reporting live temperature (and humidity, for the internal channel) and flagging when readings cross configured thresholds, which is the core function of this class of standalone environmental sensor. It defines its own compact vendor object tree under the "comet" enterprise branch with no significant dependency on other MIBs. It is deployed as a standalone networked probe in server rooms, comms closets, and equipment cabinets to provide independent, out-of-band temperature/humidity alerting. Engineers can download the T0510-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in T0510-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- current temperature (external and internal probe)
- current humidity (internal probe)
- configured low/high temperature thresholds
- alarm hysteresis settings
- last reading timestamp
Supported Devices
- COMET System T0510 networked temperature/humidity sensor
Monitoring Examples
An administrator would poll temperature and temperaturei to get the current external and internal-probe readings, comparing them against configured templow/temphigh and humiditylowi thresholds to detect an overheating or overcooled server room. The tempHyst/tempHysti hysteresis values determine how much the reading must fall back within range before an alarm clears, and temptime/temptimei record when each reading was last taken, letting an operator confirm the sensor is actively reporting rather than stalled.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| comet | 1.3.6.1.4.1.22626 | |||
| products | 1.3.6.1.4.1.22626.1 | |||
| t0510 | 1.3.6.1.4.1.22626.1.2 | |||
| readings | 1.3.6.1.4.1.22626.1.2.1 | |||
| STR temperature | 1.3.6.1.4.1.22626.1.2.1.1 | DisplayString | read-only | Temperature |
| settings | 1.3.6.1.4.1.22626.1.2.2 | |||
| STR templow | 1.3.6.1.4.1.22626.1.2.2.1 | DisplayString | read-only | Temperature Limit Low |
| STR temphigh | 1.3.6.1.4.1.22626.1.2.2.2 | DisplayString | read-only | Temperature Limit High |
| INT temptime | 1.3.6.1.4.1.22626.1.2.2.7 | INTEGER | read-only | Temperature alaram delay |
| STR tempHyst | 1.3.6.1.4.1.22626.1.2.2.10 | DisplayString | read-only | Temperature hysteresis |
| readingsint | 1.3.6.1.4.1.22626.1.2.3 | |||
| INT temperaturei | 1.3.6.1.4.1.22626.1.2.3.1 | INTEGER | read-only | Temperature *10 |
| settingsint | 1.3.6.1.4.1.22626.1.2.4 | |||
| INT templowi | 1.3.6.1.4.1.22626.1.2.4.1 | INTEGER | read-write | Temperature Limit Low *10 |
| INT temphighi | 1.3.6.1.4.1.22626.1.2.4.2 | INTEGER | read-write | Temperature Limit High *10 |
| INT humiditylowi | 1.3.6.1.4.1.22626.1.2.4.3 | INTEGER | read-write | Humidity Limit Low *10 |
| INT temptimei | 1.3.6.1.4.1.22626.1.2.4.7 | INTEGER | read-write | Temperature alaram delay |
| INT tempHysti | 1.3.6.1.4.1.22626.1.2.4.10 | INTEGER | read-write | Temperature hysteresis *10 |
| INT humidityHysti | 1.3.6.1.4.1.22626.1.2.4.11 | INTEGER | read-write | Humidity hysteresis *10 |
| traps | 1.3.6.1.4.1.22626.1.2.5 | |||
| STR messageString | 1.3.6.1.4.1.22626.1.2.5.1 | DisplayString | read-only | Message giving more detailed information on alarms. |
| INT alarmTemperature | 1.3.6.1.4.1.22626.1.2.5.2 | INTEGER | read-only | Temperature alarm 0 = temperature OK 1 = temperature too high 2 = temperature too low |
| tables | 1.3.6.1.4.1.22626.1.2.6 | |||
| historyTable | 1.3.6.1.4.1.22626.1.2.6.1 | not-accessible | Table of the history values. | |
| historyEntry | 1.3.6.1.4.1.22626.1.2.6.1.1 | not-accessible | History values entries. | |
| INT histtemperature | 1.3.6.1.4.1.22626.1.2.6.1.1.1 | INTEGER | read-only | Temperature reading. |
RFC description
Comet T0510 temperature and environmental sensor monitoring for facility management.
Start monitoring COMET System T0510 networked temperature/humidity sensor (reading/alarm-threshold status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.