T0510-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; DisplayString ::= OCTET STRING comet OBJECT IDENTIFIER ::= { enterprises 22626 } products OBJECT IDENTIFIER ::= { comet 1 } t0510 OBJECT IDENTIFIER ::= { products 2 } readings OBJECT IDENTIFIER ::= { t0510 1 } settings OBJECT IDENTIFIER ::= { t0510 2 } readingsint OBJECT IDENTIFIER ::= { t0510 3 } settingsint OBJECT IDENTIFIER ::= { t0510 4 } traps OBJECT IDENTIFIER ::= { t0510 5 } tables OBJECT IDENTIFIER ::= { t0510 6 } -- Power Source MIB -- Parameters (Prefix ps) temperature OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature" ::= { readings 1 } ----------------------------------------------------------------------- -- settings ----------------------------------------------------------------------- templow OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Limit Low" ::= { settings 1 } temphigh OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature Limit High" ::= { settings 2 } temptime OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature alaram delay" ::= { settings 7 } tempHyst OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature hysteresis" ::= { settings 10 } ----------------------------------------------------------------------- -- readingsint ----------------------------------------------------------------------- temperaturei OBJECT-TYPE SYNTAX INTEGER(-2000..6000) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature *10" ::= { readingsint 1 } ----------------------------------------------------------------------- -- settingsint ----------------------------------------------------------------------- templowi OBJECT-TYPE SYNTAX INTEGER(0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Limit Low *10" ::= { settingsint 1 } temphighi OBJECT-TYPE SYNTAX INTEGER(-2000..6000) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature Limit High *10" ::= { settingsint 2 } humiditylowi OBJECT-TYPE SYNTAX INTEGER(-2000..6000) ACCESS read-write STATUS mandatory DESCRIPTION "Humidity Limit Low *10" ::= { settingsint 3 } temptimei OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature alaram delay" ::= { settingsint 7 } tempHysti OBJECT-TYPE SYNTAX INTEGER(-2000..6000) ACCESS read-write STATUS mandatory DESCRIPTION "Temperature hysteresis *10" ::= { settingsint 10 } humidityHysti OBJECT-TYPE SYNTAX INTEGER(-2000..6000) ACCESS read-write STATUS mandatory DESCRIPTION "Humidity hysteresis *10" ::= { settingsint 11 } ----------------------------------------------------------------------- messageString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Message giving more detailed information on alarms." ::= { traps 1 } alarmTemperature OBJECT-TYPE SYNTAX INTEGER(0..2) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature alarm 0 = temperature OK 1 = temperature too high 2 = temperature too low" ::= { traps 2 } historyTable OBJECT-TYPE SYNTAX SEQUENCE OF HistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of the history values." ::= { tables 1 } historyEntry OBJECT-TYPE SYNTAX HistoryEntry ACCESS not-accessible STATUS optional DESCRIPTION "History values entries." INDEX { histtemperature } ::= { historyTable 1 } HistoryEntry ::= SEQUENCE { histtemperature INTEGER } histtemperature OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading." ::= { historyEntry 1 } END