| OID symbolic | OID numeric | Type | Access | Description |
| netraCtRscMIB | 1.3.6.1.4.1.42.2.65.2 | | | The MIB module for the Netra ct 400/800 Remote System
Control Products |
| netraCtRscObjs | 1.3.6.1.4.1.42.2.65.2.1 | | | |
| netraCtRscAdminObjs | 1.3.6.1.4.1.42.2.65.2.1.1 | | | |
| INT netraCtRscAdminRscReset | 1.3.6.1.4.1.42.2.65.2.1.1.1 | INTEGER | read-write | Setting this will soft Reset only the RSC
(Remote System Controller) card.
The clear(2) setting is read-only for this variable. This
variable will always read as clear(2). |
| INT netraCtRscAdminHostReset | 1.3.6.1.4.1.42.2.65.2.1.1.2 | INTEGER | read-write | Setting netraCtRscAdminHostReset will cause either send
a break to the host, or will toggle a hard reset line.
A break will be sent if netraCtRscPanicDump conatins the
value of on(1).Otherwise, a hard reset will occur.
The clear(2) setting is read-only for this variable.
This variable will always reads as clear(2). |
| INT netraCtRscAdminXir | 1.3.6.1.4.1.42.2.65.2.1.1.3 | INTEGER | read-write | Sends a hardware xir pulse to the host when
set to true. This variable resets itself to clear(2)
after the negation of the pulse. |
| INT netraCtRscAdminNmi | 1.3.6.1.4.1.42.2.65.2.1.1.4 | INTEGER | read-write | Sends a hardware nmi pulse to the host when
set to true. This variable resets itself to clear(2)
after the negation of the pulse. |
| INT netraCtRscAdminBreak | 1.3.6.1.4.1.42.2.65.2.1.1.5 | INTEGER | read-write | Sends a break to the Host when this is set.
The clear(2) setting is read-only for this variable.
This variable will always read as clear(2). |
| netraCtRscConfigObjs | 1.3.6.1.4.1.42.2.65.2.1.2 | | | |
| INT netraCtRscGlobalPageFlag | 1.3.6.1.4.1.42.2.65.2.1.2.1 | INTEGER | read-write | An on(1) to this variable will enable paging for RSC alerts.
An off(2) will disable paging. |
| INT netraCtRscGlobalEmailFlag | 1.3.6.1.4.1.42.2.65.2.1.2.2 | INTEGER | read-write | An on(1) to this variable will enable email for RSC alerts.
An off(2) will disable email. |
| INT netraCtRscGlobalIPModeFlag | 1.3.6.1.4.1.42.2.65.2.1.2.3 | INTEGER | read-write | IP mode global flag |
| INT netraCtRscGlobalPPPFlag | 1.3.6.1.4.1.42.2.65.2.1.2.4 | INTEGER | read-write | serial configuration flag indicating whether PPP should be
the default. |
| STR netraCtRscHostname | 1.3.6.1.4.1.42.2.65.2.1.2.5 | DisplayString | read-write | name of Host connected to RSC |
| STR netraCtRscCustomerInfo | 1.3.6.1.4.1.42.2.65.2.1.2.6 | DisplayString | read-write | Customer information used in the message generated for a pager
or email alert |
| INT netraCtRscVersionBootMajor | 1.3.6.1.4.1.42.2.65.2.1.2.7 | INTEGER | read-only | RSC Firmware BootMonitor Revision Major Number |
| INT netraCtRscVersionBootMinor | 1.3.6.1.4.1.42.2.65.2.1.2.8 | INTEGER | read-only | RSC Firmware BootMonitor Revision Minor Number |
| INT netraCtRscVersionBootMicro | 1.3.6.1.4.1.42.2.65.2.1.2.9 | INTEGER | read-only | RSC Firmware BootMonitor Revision Micro Number |
| INT netraCtRscVersionMainMajor | 1.3.6.1.4.1.42.2.65.2.1.2.10 | INTEGER | read-only | RSC Core RSC Revision Major Number |
| INT netraCtRscVersionMainMinor | 1.3.6.1.4.1.42.2.65.2.1.2.11 | INTEGER | read-only | RSC Core RSC Revision Minor Number |
| INT netraCtRscVersionMainMicro | 1.3.6.1.4.1.42.2.65.2.1.2.12 | INTEGER | read-only | RSC Core RSC Revision Micro Number |
| INT netraCtRscVersionFirmwareMajor | 1.3.6.1.4.1.42.2.65.2.1.2.13 | INTEGER | read-only | RSC Core Firmware Revision Major Number |
| INT netraCtRscVersionFirmwareMinor | 1.3.6.1.4.1.42.2.65.2.1.2.14 | INTEGER | read-only | RSC Core Firmware Revision Minor Number |
| INT netraCtRscVersionFirmwareMicro | 1.3.6.1.4.1.42.2.65.2.1.2.15 | INTEGER | read-only | RSC Core Firmware Revision Micro Number |
| DAT netraCtRscTOD | 1.3.6.1.4.1.42.2.65.2.1.2.16 | DateAndTime | read-write | RSC time of day |
| STR netraCtRscEscape | 1.3.6.1.4.1.42.2.65.2.1.2.17 | DisplayString | read-write | set the first character of the 2-character escape sequence |
| INT netraCtRscHostWatchDogReboot | 1.3.6.1.4.1.42.2.65.2.1.2.18 | INTEGER | read-write | RSC monitors a heartbeat from the Solaris host.
If this heartbeat is late, then a message will be
logged, and an alarm will be set. If
netraCtRscHostWatchDogReboot is on, then the solaris
host will also be rebooted. |
| INT netraCtRscHostWatchDogTimeout | 1.3.6.1.4.1.42.2.65.2.1.2.19 | INTEGER | read-write | RSC monitors a heartbeat from the Solaris host.
This variable indicates the maximum tolerable
number of seconds between heartbeats, before RSC will
set alarm0. A setting of 0 indicates that the heartbeat
should not be monitored. |
| INT netraCtRscPanicDump | 1.3.6.1.4.1.42.2.65.2.1.2.20 | INTEGER | read-write | If set to true when netraCtRscAdminHostReset is set, then
a break will be sent to the host, causing a core dump to
be saved on the host. Otherwise, the setting of
netraCtRscAdminHostReset will cause a hardware reset. |
| netraCtRscSerial2Objs | 1.3.6.1.4.1.42.2.65.2.1.3 | | | |
| INT netraCtRscSerial2Mode | 1.3.6.1.4.1.42.2.65.2.1.3.1 | INTEGER | read-write | serial port 2 configuration mode. |
| INT netraCtRscSerial2Parity | 1.3.6.1.4.1.42.2.65.2.1.3.2 | INTEGER | read-write | serial port 2 parity mode. |
| INT netraCtRscSerial2Stop | 1.3.6.1.4.1.42.2.65.2.1.3.3 | INTEGER | read-write | serial port 2 stop bits. |
| INT netraCtRscSerial2Data | 1.3.6.1.4.1.42.2.65.2.1.3.4 | INTEGER | read-write | serial port 2 data bits. |
| INT netraCtRscSerial2Baud | 1.3.6.1.4.1.42.2.65.2.1.3.5 | INTEGER | read-write | serial port 2 baud rate. |
| INT netraCtRscSerial2HwFlowcontrol | 1.3.6.1.4.1.42.2.65.2.1.3.6 | INTEGER | read-write | serial port 2 Hardware Flowcontrol. |
| INT netraCtRscSerial2Inactivity | 1.3.6.1.4.1.42.2.65.2.1.3.7 | INTEGER | read-write | serial port 2 inactivity. |
| netraCtRscModemObjs | 1.3.6.1.4.1.42.2.65.2.1.4 | | | |
| INT netraCtRscModemParity | 1.3.6.1.4.1.42.2.65.2.1.4.1 | INTEGER | read-write | modem parity mode. |
| INT netraCtRscModemStop | 1.3.6.1.4.1.42.2.65.2.1.4.2 | INTEGER | read-write | modem stop bits. |
| INT netraCtRscModemData | 1.3.6.1.4.1.42.2.65.2.1.4.3 | INTEGER | read-write | modem data bits. |
| INT netraCtRscCountryCode | 1.3.6.1.4.1.42.2.65.2.1.4.4 | INTEGER | read-write | country specified using CCITT internaional dial-plan number. |
| STR netraCtRscModemModel | 1.3.6.1.4.1.42.2.65.2.1.4.5 | DisplayString | read-only | the modem type used on the netraCtRsc card. |
| netraCtRscEnetObjs | 1.3.6.1.4.1.42.2.65.2.1.5 | | | |
| MAC netraCtRscMacAddress | 1.3.6.1.4.1.42.2.65.2.1.5.1 | MacAddress | read-only | Ethernet address for RSC. |
| INT netraCtRscEnetTpeLinkTest | 1.3.6.1.4.1.42.2.65.2.1.5.2 | INTEGER | read-write | Determines whether tpe-link-test should be set of clear.
This should be off when interfacing with older-style hubs
that don't support heartbeat. |
| IP netraCtRscIPAddress | 1.3.6.1.4.1.42.2.65.2.1.5.3 | IpAddress | read-write | configured IP address for RSC. |
| IP netraCtRscIpMask | 1.3.6.1.4.1.42.2.65.2.1.5.4 | IpAddress | read-write | configured IP netmask for RSC. |
| IP netraCtRscIpGateway | 1.3.6.1.4.1.42.2.65.2.1.5.5 | IpAddress | read-write | configured IP gateway for RSC. |
| IP netraCtRscSNMPHostAddress | 1.3.6.1.4.1.42.2.65.2.1.5.6 | IpAddress | read-write | configured SNMP server for RSC alerts. |
| IP netraCtRscMailHostAddress | 1.3.6.1.4.1.42.2.65.2.1.5.7 | IpAddress | read-write | Address of Mail Server. |
| STR netraCtRscMailUser | 1.3.6.1.4.1.42.2.65.2.1.5.8 | DisplayString | read-write | email address for RSC alerts. |
| IP netraCtRscPPPLocalIP | 1.3.6.1.4.1.42.2.65.2.1.5.9 | IpAddress | read-write | PPP local IP address. |
| IP netraCtRscPPPRemoteIP | 1.3.6.1.4.1.42.2.65.2.1.5.10 | IpAddress | read-write | PPP remote IP address. |
| IP netraCtRscMailHostAddressBackup | 1.3.6.1.4.1.42.2.65.2.1.5.11 | IpAddress | read-write | Backup Address of Mail Server. when no IP address is
configured for mail server, back up IP address becomes
first IP address of mailhost |
| netraCtRscEnvObjs | 1.3.6.1.4.1.42.2.65.2.1.6 | | | |
| STR netraCtRscSystemType | 1.3.6.1.4.1.42.2.65.2.1.6.1 | DisplayString | read-only | System Type. This will currently return
one of the following 2 strings:
NetraCt400 , or
NetraCt800. |
| INT netraCtRscPowerSupplyCount | 1.3.6.1.4.1.42.2.65.2.1.6.2 | INTEGER | read-only | The total number of Power Supply FRUs in the platform. |
| netraCtRscPowerSupplyTable | 1.3.6.1.4.1.42.2.65.2.1.6.3 | | not-accessible | A table listing the characteristics of the Power-Supply FRU. |
| netraCtRscPowerSupplyEntry | 1.3.6.1.4.1.42.2.65.2.1.6.3.1 | | not-accessible | an entry (conceptual row) in the netraCtRscPowerSupplyTable |
| INT netraCtRscPowerSupplyIndex | 1.3.6.1.4.1.42.2.65.2.1.6.3.1.1 | INTEGER | read-only | Entry number for this Power-Supply FRU row. |
| INT netraCtRscPowerSupplyPresent | 1.3.6.1.4.1.42.2.65.2.1.6.3.1.2 | INTEGER | read-only | Power-Supply FRU is present. |
| INT netraCtRscPowerSupplyOperState | 1.3.6.1.4.1.42.2.65.2.1.6.3.1.3 | INTEGER | read-only | The current status of the Power-Supply FRU. |
| INT netraCtRscPowerSupplyAdminState | 1.3.6.1.4.1.42.2.65.2.1.6.3.1.4 | INTEGER | read-write | Setting this value to on(1) requests that the power
supply be turned on. Setting this value to off(2)
requests that the power supply be turned off. |
| INT netraCtRscAlarmCount | 1.3.6.1.4.1.42.2.65.2.1.6.4 | INTEGER | read-only | Number of Alarm Ports in this Platform |
| netraCtRscAlarmTable | 1.3.6.1.4.1.42.2.65.2.1.6.5 | | not-accessible | a table listing the available Alarm Ports. |
| netraCtRscAlarmEntry | 1.3.6.1.4.1.42.2.65.2.1.6.5.1 | | not-accessible | an entry (conceptual row) in the netraCtRscAlarmTable. |
| INT netraCtRscAlarmIndex | 1.3.6.1.4.1.42.2.65.2.1.6.5.1.1 | INTEGER | not-accessible | row index into Alarm Port table |
| INT netraCtRscAlarmID | 1.3.6.1.4.1.42.2.65.2.1.6.5.1.2 | INTEGER | read-only | Alarm identifier. The current Netra ct 400/800 Alarm Cards
currently supports Alarm IDs of 0,1,2, and 3. |
| INT netraCtRscAlarmOperState | 1.3.6.1.4.1.42.2.65.2.1.6.5.1.3 | INTEGER | read-only | This returns the current value of the Alarm, which may
have been set by either software due to environmental
conditions, such as Fan failure, or manually, by the
setting of netraCtRscAlarmAdminState. |
| INT netraCtRscAlarmAdminState | 1.3.6.1.4.1.42.2.65.2.1.6.5.1.4 | INTEGER | read-write | This reflects the requested state of an alarm port by
the SNMP manager. |
| INT netraCtRscAlarmPrefix | 1.3.6.1.4.1.42.2.65.2.1.6.5.1.5 | INTEGER | read-only | The Alarm Prefix that will associate an FRU type to an alarm.
Currently supported definitions are:
cpuunit(1),
software(2),
powersupply(3),
temperature(4),
fan(5).
6 through 9 are reserved for future expansion.
10 through 255 are undefined, and can be configured for
user-defined messages and alarming. |
| INT netraCtRscFanCount | 1.3.6.1.4.1.42.2.65.2.1.6.6 | INTEGER | read-only | Maximum number of Fan Tray FRUs in Platform |
| netraCtRscFanTable | 1.3.6.1.4.1.42.2.65.2.1.6.7 | | not-accessible | a table listing the characteristics of the Fan Tray FRU. |
| netraCtRscFanEntry | 1.3.6.1.4.1.42.2.65.2.1.6.7.1 | | not-accessible | an entry (conceptual row) in the netraCtRscFanTable. |
| INT netraCtRscFanIndex | 1.3.6.1.4.1.42.2.65.2.1.6.7.1.1 | INTEGER | read-only | row index into Fan FRU table |
| INT netraCtRscFanPresent | 1.3.6.1.4.1.42.2.65.2.1.6.7.1.2 | INTEGER | read-only | Fan FRU is present |
| INT netraCtRscFanStatus | 1.3.6.1.4.1.42.2.65.2.1.6.7.1.3 | INTEGER | read-only | The current status of the Fan FRU.
unknown will be returned if the status is unknown. |
| INT netraCtRscTemperatureCount | 1.3.6.1.4.1.42.2.65.2.1.6.8 | INTEGER | read-only | Maximum number of temperature sensors on Platform |
| netraCtRscTemperatureTable | 1.3.6.1.4.1.42.2.65.2.1.6.9 | | not-accessible | a table listing the contents of the event log as an
array of strings. |
| netraCtRscTemperatureEntry | 1.3.6.1.4.1.42.2.65.2.1.6.9.1 | | not-accessible | an entry (conceptual row) in the netraCtRscTemperatureTable. |
| INT netraCtRscTemperatureIndex | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.1 | INTEGER | read-only | current row of the Temperature sensor |
| INT netraCtRscTemperatureValid | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.2 | INTEGER | read-only | The current temperature at this sensor is known.
If the temperature cannot be obtained, then false
will be returned, and netraCtRscTemperatureValue should
not be considered to be valid. |
| INT netraCtRscTemperatureValue | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.3 | INTEGER | read-only | current temperature at this sensor |
| INT netraCtRscTemperatureLowWarn | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.4 | INTEGER | read-only | low warning threshold for this temperature sensor |
| INT netraCtRscTemperatureHighWarn | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.5 | INTEGER | read-only | high warning threshold for this temperature sensor |
| STR netraCtRscTemperatureDesc | 1.3.6.1.4.1.42.2.65.2.1.6.9.1.6 | DisplayString | read-only | textual description of the Temperature sensor |
| netraCtRscLogObjs | 1.3.6.1.4.1.42.2.65.2.1.7 | | | |
| INT netraCtRscEventLogCount | 1.3.6.1.4.1.42.2.65.2.1.7.1 | INTEGER | read-only | current number of lines in the event log |
| netraCtRscEventLogTable | 1.3.6.1.4.1.42.2.65.2.1.7.2 | | not-accessible | a table listing the contents of the event log as an
array of strings. |
| netraCtRscEventLogEntry | 1.3.6.1.4.1.42.2.65.2.1.7.2.1 | | not-accessible | an entry (conceptual row) in the netraCtRscEventLogTable. |
| INT netraCtRscEventLogIndex | 1.3.6.1.4.1.42.2.65.2.1.7.2.1.1 | INTEGER | read-only | The index of the entry. The oldest entry will start at index 0.
The most recent entry will be found at the index equal to
netraCtRscEventLogCount - 1. |
| DAT netraCtRscEventLogTimeStamp | 1.3.6.1.4.1.42.2.65.2.1.7.2.1.2 | DateAndTime | read-only | event timestamp |
| STR netraCtRscEventLogMessage | 1.3.6.1.4.1.42.2.65.2.1.7.2.1.3 | DisplayString | read-only | textual description of an event. |
| INT netraCtRscOrigConsoleLogCount | 1.3.6.1.4.1.42.2.65.2.1.7.3 | INTEGER | read-only | current number of lines in the original console log. |
| netraCtRscOrigConsoleLogTable | 1.3.6.1.4.1.42.2.65.2.1.7.4 | | not-accessible | a table listing the contents of the original console
log as an array of strings. |
| netraCtRscOrigConsoleLogEntry | 1.3.6.1.4.1.42.2.65.2.1.7.4.1 | | not-accessible | an entry (conceptual row) in the netraCtRscOrigConsoleLogTable. |
| INT netraCtRscOrigConsoleLogIndex | 1.3.6.1.4.1.42.2.65.2.1.7.4.1.1 | INTEGER | read-only | The index of the entry. The oldest entry will start at index 0.
The most recent entry will be found at the index equal to
netraCtRscOrigConsoleLogCount - 1. |
| DAT netraCtRscOrigConsoleLogTimeStamp | 1.3.6.1.4.1.42.2.65.2.1.7.4.1.2 | DateAndTime | read-only | Original Console Log timestamp |
| STR netraCtRscOrigConsoleLogMessage | 1.3.6.1.4.1.42.2.65.2.1.7.4.1.3 | DisplayString | read-only | textual description of an event. |
| INT netraCtRscConsoleLogCount | 1.3.6.1.4.1.42.2.65.2.1.7.5 | INTEGER | read-only | current number of lines in the console log. |
| netraCtRscConsoleLogTable | 1.3.6.1.4.1.42.2.65.2.1.7.6 | | not-accessible | a table listing the contents of the console log as an
array of strings. |
| netraCtRscConsoleLogEntry | 1.3.6.1.4.1.42.2.65.2.1.7.6.1 | | not-accessible | an entry (conceptual row) in the netraCtRscConsoleLogTable. |
| INT netraCtRscConsoleLogIndex | 1.3.6.1.4.1.42.2.65.2.1.7.6.1.1 | INTEGER | read-only | The index of the entry. The oldest entry will start at index 0.
The most recent entry will be found at the index equal to
netraCtRscConsoleLogCount - 1. |
| DAT netraCtRscConsoleLogTimeStamp | 1.3.6.1.4.1.42.2.65.2.1.7.6.1.2 | DateAndTime | read-only | Console Log timestamp |
| STR netraCtRscConsoleLogMessage | 1.3.6.1.4.1.42.2.65.2.1.7.6.1.3 | DisplayString | read-only | textual description of an event. |
| INT netraCtRscConsoleReset | 1.3.6.1.4.1.42.2.65.2.1.7.7 | INTEGER | read-write | When set, the console log is reset so that the current
log is copied over to the original console log, and the
the console log will be cleared. All new console messages
will then go to the console log.clear(2) setting is read-only. |
| netraCtRscEvents | 1.3.6.1.4.1.42.2.65.2.2 | | | |
| netraCtRscTrapPrefix | 1.3.6.1.4.1.42.2.65.2.2.0 | | | |
| NTF netraCtRscEvent | 1.3.6.1.4.1.42.2.65.2.2.0.1 | | | Event used to notify the snmp manager of a new RSC event.
An event is generated when one of the values:
netraCtRscAlarmOperState, in the Table:netraCtRscAlarmTable
changes state. |
| netraCtRscExpmnt | 1.3.6.1.4.1.42.2.65.2.3 | | | |
| netraCtRscRccConfig | 1.3.6.1.4.1.42.2.65.2.3.1 | | | |
| INT netraCtRscRCCPowerOnEnable | 1.3.6.1.4.1.42.2.65.2.3.1.1 | INTEGER | read-write | If set to false, masks the RCC PowerOn command. |
| INT netraCtRscRCCPowerOffEnable | 1.3.6.1.4.1.42.2.65.2.3.1.2 | INTEGER | read-write | If set to false, masks the RCC PowerOff command. |
| INT netraCtRscRCCResetEnable | 1.3.6.1.4.1.42.2.65.2.3.1.3 | INTEGER | read-write | If set to false, masks the RCC Reset command. |
| STR netraCtRscRCCLinkNum | 1.3.6.1.4.1.42.2.65.2.3.1.4 | DisplayString | read-write | 2-byte string that defines the RCC Linknum address. |