| OID symbolic | OID numeric | Type | Access | Description |
| nas | 1.3.6.1.4.1.429.1 | | | |
| ss7i | 1.3.6.1.4.1.429.1.35 | | | |
| ss7iCfg | 1.3.6.1.4.1.429.1.35.1 | | | |
| OCT ss7iCfgChassisId | 1.3.6.1.4.1.429.1.35.1.1.1.13 | OCTET STRING | read-write | This uniquely identifies logical Chassis under the control
of the HiPer SS7I, valid for SLAP only. The OCTET STRING
format must be FF FF FF FF . |
| IP ss7iCfgDfltGwIpAddr | 1.3.6.1.4.1.429.1.35.1.1.1.4 | IpAddress | read-write | The IP address of the default IP routing gateway. |
| ss7iCfgEntry | 1.3.6.1.4.1.429.1.35.1.1.1 | | not-accessible | There is one Configuration Table entry per HiPer SS7i Card
in the chassis. |
| INT ss7iCfgGwConnRetryCnt | 1.3.6.1.4.1.429.1.35.1.1.1.14 | INTEGER | read-write | The number of times the HiPer SS7i will attempt to
re-establish the TCP/IP connection to the external SS7
gateway after the initial failure was detected. Valid for
SLAP only. Default = 3. |
| INT ss7iCfgGwConnRetryIntvl | 1.3.6.1.4.1.429.1.35.1.1.1.15 | INTEGER | read-write | The time interval between attempts of the HiPer SS7i to
re-establish the TCP/IP connection to the external SS7
gateway. Valid for SLAP only. Default = 2 sec. |
| INT ss7iCfgGwConnStartMethod | 1.3.6.1.4.1.429.1.35.1.1.1.6 | INTEGER | read-write | The method used by the HiPer SS7i to bring up the TCP/IP
connection to the external signaling gateway at boot time. |
| IP ss7iCfgGwIpAddr | 1.3.6.1.4.1.429.1.35.1.1.1.7 | IpAddress | read-write | The primary external SS7 gateway IP address. Valid for
SLAP only. |
| INT ss7iCfgGwMssdHrtbtThrsh | 1.3.6.1.4.1.429.1.35.1.1.1.16 | INTEGER | read-write | The number of external SS7 gateway heartbeat timeouts
allowed before the connection to the gateway is considered
lost. A setting of 0 means no attempt will be made to
re-establish the connection. Default = 1. |
| INT ss7iCfgGwPort | 1.3.6.1.4.1.429.1.35.1.1.1.8 | INTEGER | read-write | The primary external SS7 gateway port number. Valid for
SLAP only. |
| INT ss7iCfgHrtbtTimerFarEnd | 1.3.6.1.4.1.429.1.35.1.1.1.12 | INTEGER | read-write | The external SS7 gateway heartbeat timer. Upon expiration
it causes the HiPer SS7i to commence the connection
re-establishment procedure to the external SS7 gateway.
The time should be longer than what the external SS7
gateway is set to. Valid for SLAP only. Default = 15000
msec. |
| INT ss7iCfgHrtbtTimerNearEnd | 1.3.6.1.4.1.429.1.35.1.1.1.11 | INTEGER | read-write | The HiPer SS7i heartbeat timer. Upon expiration, the HiPer
SS7i will send a heartbeat message to the external SS7
gateway. The time should be less than what the gateway
expects. Valid for SLAP only. Default = 15000 msec. |
| INT ss7iCfgIndex | 1.3.6.1.4.1.429.1.35.1.1.1.1 | INTEGER | read-only | A unique value for each HiPer SS7i card in the chassis.
The value of ss7iCfgIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
| IP ss7iCfgIpAddr | 1.3.6.1.4.1.429.1.35.1.1.1.2 | IpAddress | read-write | The IP address on interface 0 of the HiPer SS7i. |
| IP ss7iCfgNetmask | 1.3.6.1.4.1.429.1.35.1.1.1.3 | IpAddress | read-write | The netmask on interface 0 of the HiPer SS7i. |
| INT ss7iCfgProtocol | 1.3.6.1.4.1.429.1.35.1.1.1.5 | INTEGER | read-write | The external signaling protocol running over the TCP/IP
connection with the external signaling gateway. Default =
hss7iSlapV2(1). |
| IP ss7iCfgSecGwIpAddr | 1.3.6.1.4.1.429.1.35.1.1.1.9 | IpAddress | read-write | The secondary external SS7 gateway IP address. Valid for
SLAP only. |
| INT ss7iCfgSecGwPort | 1.3.6.1.4.1.429.1.35.1.1.1.10 | INTEGER | read-write | The secondary external SS7 gateway port number. Valid for
SLAP only. |
| ss7iCfgTable | 1.3.6.1.4.1.429.1.35.1.1 | | not-accessible | The Configuration Table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It contains
objects that reflect the current configuration of
parameters that affect the operation of all the entities
that reside on the given card. |
| ss7iCmd | 1.3.6.1.4.1.429.1.35.2 | | | |
| INT ss7iCmdCode | 1.3.6.1.4.1.429.1.35.2.1.1.8 | INTEGER | read-only | The value of this object upon command completion indicates
a further description of what went wrong if the command was
unsuccessful. In the case of tests, a bit mapped result of
each of the sub-tests performed can be found in the status
table. |
| ss7iCmdEntry | 1.3.6.1.4.1.429.1.35.2.1.1 | | not-accessible | There is one Command Table entry per HiPer SS7i card in the
chassis. |
| INT ss7iCmdForce | 1.3.6.1.4.1.429.1.35.2.1.1.5 | INTEGER | read-write | In some cases, the HiPer SS7i card may be in a state such
that certain commands could adversely affect connections.
In such cases, a command request with this object not
present or set to noForce will result in a warning. If the
operator elects to ignore such warnings, this object can be
set to force in a subsequent issue of the command to cause
the command to be carried out regardless of its potentially
hazzardous effects. |
| INT ss7iCmdFunction | 1.3.6.1.4.1.429.1.35.2.1.1.4 | INTEGER | read-write | This object contains a value which describes the command
which is being invoked. |
| INT ss7iCmdIndex | 1.3.6.1.4.1.429.1.35.2.1.1.1 | INTEGER | read-only | A unique value for each HiPer SS7i card in the chassis.
The value of this object matches the value of the index of
the corresponding HiPer SS7i card's entry in the entity
table of the chassis MIB. |
| OCT ss7iCmdMgtStationId | 1.3.6.1.4.1.429.1.35.2.1.1.2 | OCTET STRING | read-write | This object is a generic read-write variable that a
Management Station (MS) can use to guarantee that the
results from a given command are the results of a command
issued by that specific MS. Each MS must SET a unique
value to this object when doing commands and GET the value
of this object together with ss7iCmdReqId and ss7iCmdResult
to detect interference from other MSs. |
| OCT ss7iCmdParam | 1.3.6.1.4.1.429.1.35.2.1.1.6 | OCTET STRING | read-write | This object contains parameters that are specific to the
particular command being issued. In some cases, there will
be no aditional parameters required. |
| INT ss7iCmdReqId | 1.3.6.1.4.1.429.1.35.2.1.1.3 | INTEGER | read-only | This object contains the value of the request-id field in
the SNMP PDU which invoked the current or most recent
command or test on this HiPer SS7i card. If the request-id
is unknown or undefined, this object contains the value
zero. |
| INT ss7iCmdResult | 1.3.6.1.4.1.429.1.35.2.1.1.7 | INTEGER | read-only | This object contains the result of the most recently
requested command or test, or the value none(1) if no
commands have been requested since the last reset. |
| ss7iCmdTable | 1.3.6.1.4.1.429.1.35.2.1 | | not-accessible | The Command table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It provides a
means through which to take specific actions on them. |
| ss7iHdm | 1.3.6.1.4.1.429.1.35.5 | | | |
| INT ss7iHdmConnState | 1.3.6.1.4.1.429.1.35.5.1.1.3 | INTEGER | read-only | The state of the signaling packet bus connection to the
HiPer Dsp. There is one connection from the HiPer SS7i
card to each HiPer Dsp in the chassis. |
| ss7iHdmEntry | 1.3.6.1.4.1.429.1.35.5.1.1 | | not-accessible | There is one entry for each HiPer Dsp Card in the chassis. |
| INT ss7iHdmIndex | 1.3.6.1.4.1.429.1.35.5.1.1.1 | INTEGER | read-only | A unique value for each HiPer SS7i card in the chassis.
The value of ss7iHdmIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
| INT ss7iHdmIndex2 | 1.3.6.1.4.1.429.1.35.5.1.1.2 | INTEGER | read-only | The secondary index into the ss7iHdm table. There is one
entry for each Hiper Dsp in the chassis. The value of the
index is equal to the chassis slot number of a HiPer Dsp
card. |
| INT ss7iHdmLinkDownCause | 1.3.6.1.4.1.429.1.35.5.1.1.8 | INTEGER | read-only | The reason the packet bus ENFAS signaling link to the HiPer
Dsp went down. |
| CTR ss7iHdmRcvPktsFailCnt | 1.3.6.1.4.1.429.1.35.5.1.1.7 | Counter | read-only | The number of signaling packet bus connection packets
rejected by the HiPer SS7i message handler. |
| CTR ss7iHdmRcvPktsOkCnt | 1.3.6.1.4.1.429.1.35.5.1.1.6 | Counter | read-only | The number of packets sucessfully received over the
signaling packet bus connection. |
| CTR ss7iHdmSndPktsFailCnt | 1.3.6.1.4.1.429.1.35.5.1.1.5 | Counter | read-only | The number of packets failing to transmit over the
signaling packet bus connection. |
| CTR ss7iHdmSndPktsOkCnt | 1.3.6.1.4.1.429.1.35.5.1.1.4 | Counter | read-only | The number of packets successfully transmitted over the
signaling packet bus connection. |
| ss7iHdmTable | 1.3.6.1.4.1.429.1.35.5.1 | | not-accessible | The ss7iHdm table contains objects for all of the HiPer Dsp
cards in the chassis. |
| ss7iSigPb | 1.3.6.1.4.1.429.1.35.6 | | | |
| INT ss7iSigPbConnection | 1.3.6.1.4.1.429.1.35.6.1.1.3 | INTEGER | read-write | The means to enable or disable a signaling packet bus
connection between the HiPer SS7i and a Hiper Dsp. Default
= disable(1). |
| ss7iSigPbEntry | 1.3.6.1.4.1.429.1.35.6.1.1 | | not-accessible | There is one entry for each HiPer Dsp Card in the chassis. |
| INT ss7iSigPbIndex | 1.3.6.1.4.1.429.1.35.6.1.1.1 | INTEGER | read-only | A unique value for each HiPer SS7i card in the chassis.
The value of ss7iSigPbIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
| INT ss7iSigPbIndex2 | 1.3.6.1.4.1.429.1.35.6.1.1.2 | INTEGER | read-only | The secondary index into the ss7iSigPb table. There is one
entry for each Hiper Dsp in the chassis. The value of the
index is equal to the chassis slot number of a HiPer Dsp
card. |
| INT ss7iSigPbLoopback | 1.3.6.1.4.1.429.1.35.6.1.1.4 | INTEGER | read-write | The means to enable or disable the loopback state on the
signaling packet bus connection between the HiPer SS7i and
a Hiper Dsp. Default = disable(1). |
| ss7iSigPbTable | 1.3.6.1.4.1.429.1.35.6.1 | | not-accessible | The ss7iSigPb table contains objects for managing the
signaling packet bus connections to all of the HiPer Dsp
cards in the chassis. |
| ss7iStat | 1.3.6.1.4.1.429.1.35.4 | | | |
| ss7iStatEntry | 1.3.6.1.4.1.429.1.35.4.1.1 | | not-accessible | There is one Statistics table entry for each HiPer SS7i
card in the chassis. |
| INT ss7iStatGwConnStatus | 1.3.6.1.4.1.429.1.35.4.1.1.2 | INTEGER | read-only | Status of the TCP/IP connection with the external signaling
gateway. Valid for SLAP only. |
| INT ss7iStatGwLinkDownCause | 1.3.6.1.4.1.429.1.35.4.1.1.10 | INTEGER | read-only | The reason the signaling connection to the external SS7
gateway went down. |
| CTR ss7iStatGwLinkErrCnt | 1.3.6.1.4.1.429.1.35.4.1.1.9 | Counter | read-only | The accumulated number of errors encountered sending to or
receiving from the external SS7 gateway when the TCP/IP
connection is believed to be healthy. |
| CTR ss7iStatGwLinkLostCnt | 1.3.6.1.4.1.429.1.35.4.1.1.8 | Counter | read-only | The accumulated number of times the physical Ethernet
connection is unplugged or severed. |
| CTR ss7iStatGwMssdHrtbtCnt | 1.3.6.1.4.1.429.1.35.4.1.1.7 | Counter | read-only | The accumulated number of missed heartbeat messages
expected to arrive from the external SS7 gateway. |
| CTR ss7iStatGwNumBytesRcvd | 1.3.6.1.4.1.429.1.35.4.1.1.4 | Counter | read-only | The number of bytes received from the external SS7 gateway
or the Media Gateway Controller. |
| CTR ss7iStatGwNumBytesSent | 1.3.6.1.4.1.429.1.35.4.1.1.6 | Counter | read-only | The number of bytes sent to the external SS7 gateway or the
Media Gateway Controller. |
| CTR ss7iStatGwNumMsgsRcvd | 1.3.6.1.4.1.429.1.35.4.1.1.3 | Counter | read-only | The number of messages received from the external SS7
gateway or the Media Gateway Controller. |
| CTR ss7iStatGwNumMsgsSent | 1.3.6.1.4.1.429.1.35.4.1.1.5 | Counter | read-only | The number of messages sent to the external SS7 gateway or
the Media Gateway Controller. |
| INT ss7iStatIndex | 1.3.6.1.4.1.429.1.35.4.1.1.1 | INTEGER | read-only | A unique value for each HiPer SS7i card in the chassis.
The value of ss7iStatIndex matches the value of the index
for the corresponding Hiper SS7i card entity in the entity
table of the chassis MIB. |
| ss7iStatTable | 1.3.6.1.4.1.429.1.35.4.1 | | not-accessible | The Statistics table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It contains
objects that reflect the current status of the card. |
| ss7iTrap | 1.3.6.1.4.1.429.1.35.3 | | | |
| ss7iTrapEntry | 1.3.6.1.4.1.429.1.35.3.1.1 | | not-accessible | There is one entry for each HiPer SS7i card in the
chassis. |
| INT ss7iTrapGwConnDown | 1.3.6.1.4.1.429.1.35.3.1.1.5 | INTEGER | read-write | Enables reporting of a trap and/or log message when the
TCP/IP signaling connection to the SS7 (or media) gateway
goes down. Default = disableAll(2). |
| INT ss7iTrapGwConnUp | 1.3.6.1.4.1.429.1.35.3.1.1.4 | INTEGER | read-write | Enables reporting of a trap and/or log message when the
TCP/IP signaling connection to the SS7 (or media) gateway
comes up. Default = disableAll(2). |
| INT ss7iTrapIndex | 1.3.6.1.4.1.429.1.35.3.1.1.1 | INTEGER | read-only | A unique index identifying the HiPer SS7i card to which the
trap enable objects pertain. |
| INT ss7iTrapPbusLinkDown | 1.3.6.1.4.1.429.1.35.3.1.1.3 | INTEGER | read-write | Enables reporting of a trap and/or log message when the
ENFAS packet bus signaling link to the HiPer Dsp goes down.
Default = disableAll(2). |
| INT ss7iTrapPbusLinkUp | 1.3.6.1.4.1.429.1.35.3.1.1.2 | INTEGER | read-write | Enables reporting of a trap and/or log message when the
ENFAS packet bus signaling link to the HiPer Dsp comes up.
Default = disableAll(2). |
| ss7iTrapTable | 1.3.6.1.4.1.429.1.35.3.1 | | not-accessible | Table containing objects to enable traps on the HiPer SS7i
cards in the chassis. |
| usr | 1.3.6.1.4.1.429 | | | |