SONUS-REDUNDANCY-SERVICES-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SONUS-REDUNDANCY-SERVICES-MIB

Organization: Sonus Networks, Inc.

Last Updated: 2001-04-18

Category: Sonus Networks VoIP Softswitch

Description: Covers redundancy service configuration, active/standby state, and failover controls on the Sonus Networks softswitch.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is SONUS-REDUNDANCY-SERVICES-MIB?

SONUS-REDUNDANCY-SERVICES-MIB manages redundancy group configuration, active/standby state, and failover controls on Sonus Networks softswitches and media gateways. It exposes a redundancy group table describing which control card is active and which is standby, along with switchover and fallback control settings. Monitoring this MIB gives visibility into the health of the device's high-availability software, showing whether a redundancy group is stable, whether a switchover has occurred, and whether the system is configured to auto-revert to the primary card, all of which speak directly to hardware/control-card failover status. It shares shelf/slot addressing conventions with other Sonus MIBs like the IP interface MIB, indicating a coordinated vendor MIB family rather than dependency on an external standard. It is deployed in carrier telecom Sonus systems configured for 1:1 or N:1 control-card redundancy. Engineers can download the SONUS-REDUNDANCY-SERVICES-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in SONUS-REDUNDANCY-SERVICES-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Sonus Networks softswitch
  • Sonus media gateway with redundant control cards

Monitoring Examples

sonusRedundGroupTable/sonusRedundGroupEntry exposes sonusRedundGroupAdmnState and sonusRedundGroupSwitchoverCntrl per group identified by sonusRedundGroupShelfIndex/sonusRedundGroupRedundSlotIndex, letting an admin confirm which slot is currently active. sonusRedundGroupWaitToRevertTime and sonusRedundGroupFallbackCntrl show whether the system will auto-revert to the primary slot after a failover; an admin would poll sonusRedundGroupSwitchoverClientSlotIndex to detect an unexpected or stuck switchover indicating a hardware fault on the primary card.

What Can Be Monitored

  • active/standby redundancy group state
  • switchover control status
  • fallback/revert configuration
  • redundant slot identity
  • wait-to-revert timer
Imported Objects

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE

From SNMPv2-TC

RowStatus

From SONUS-COMMON-MIB

sonusEventClassOBJECT-TYPE
sonusEventDescriptionOBJECT-TYPE
sonusEventLevelOBJECT-TYPE
sonusShelfIndexOBJECT-TYPE
sonusSlotIndexOBJECT-TYPE

From SONUS-SMI

sonusServicesMIBsOBJECT-IDENTITY

From SONUS-TC

ServerFunctionType
ServerTypeID
SonusName
OIDs

RFC description

Manages Sonus Networks softswitch redundancy service configuration, active/standby state, and failover controls.

Start monitoring Sonus Networks softswitch, Sonus media gateway with redundant control cards (active/standby failover status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download SONUS-REDUNDANCY-SERVICES-MIB