All MIBs › SLE-OSPFv3-MIB › sleOspfv3ProcAreaVlinkDeadInterval
sleOspfv3ProcAreaVlinkDeadInterval
Module: SLE-OSPFv3-MIB
OID (symbolic): SLE-OSPFv3-MIB::sleOspfv3ProcAreaVlinkDeadInterval
OID (numeric): 1.3.6.1.4.1.6296.101.52.2.5.3.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Dead router detection time in unit of second. The value of 0 means that this virtual-link has not specific dead-interval.
What is sleOspfv3ProcAreaVlinkDeadInterval?
Read-only dead-router detection timeout in seconds (1-65535, 0 meaning no specific override) for this virtual link. Admins tune it, together with sleOspfv3ProcAreaVlinkHelloInterval, to control how quickly a failed virtual-link neighbor is declared down.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6296.101.52.2.5.3.1.1.2 snmpwalk -v2c -c public <target> SLE-OSPFv3-MIB::sleOspfv3ProcAreaVlinkDeadInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6296.101.52.2.5.3.1.1.2.1 snmpget -v2c -c public <target> SLE-OSPFv3-MIB::sleOspfv3ProcAreaVlinkDeadInterval.1
Start monitoring DASAN Networks SLE-series OLT/aggregation node (OSPFv3 neighbor/area status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SLE-OSPFv3-MIB::sleOspfv3ProcAreaVlinkDeadInterval OID value, configure state conditions and alerts, and monitor any DASAN Networks SLE-series OLT/aggregation node (OSPFv3 neighbor/area status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6296 | dasan | DASAN-DHCP-MIB |
| 1.3.6.1.4.1.6296.101 | sleMgmt | DASAN-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6296.101.52 | sleOSPFv3 | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2 | sleOspfv3Proc | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2.5 | sleOspfv3ProcArea | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2.5.3 | sleOspfv3ProcAreaVlink | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2.5.3.1 | sleOspfv3ProcAreaVlinkTable | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2.5.3.1.1 | sleOspfv3ProcAreaVlinkEntry | SLE-OSPFv3-MIB |
| 1.3.6.1.4.1.6296.101.52.2.5.3.1.1.2 | sleOspfv3ProcAreaVlinkDeadInterval | SLE-OSPFv3-MIB |