All MIBs › SLE-MPLS-TP-VPLS-MIB › sleMplsTpVplsCfgControlDescription
sleMplsTpVplsCfgControlDescription
Module: SLE-MPLS-TP-VPLS-MIB
OID (symbolic): SLE-MPLS-TP-VPLS-MIB::sleMplsTpVplsCfgControlDescription
OID (numeric): 1.3.6.1.4.1.6296.101.16.16.1.2.11
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-write
Description: Description of VPLS.
What is sleMplsTpVplsCfgControlDescription?
The free-text description an admin supplies through the control table when issuing a setVplsDescription request against a VPLS instance. It becomes the value later reported by the read-only sleMplsTpVplsCfgInfoDescription.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6296.101.16.16.1.2.11 snmpwalk -v2c -c public <target> SLE-MPLS-TP-VPLS-MIB::sleMplsTpVplsCfgControlDescription
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6296.101.16.16.1.2.11.1 snmpget -v2c -c public <target> SLE-MPLS-TP-VPLS-MIB::sleMplsTpVplsCfgControlDescription.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6296.101.16.16.1.2.11.1 s <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sleMplsTpVplsCfgControlDescription.1
Start monitoring DASAN Networks SLE OLT, carrier Ethernet / MPLS-TP access switch (VPLS instance/pseudowire status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SLE-MPLS-TP-VPLS-MIB::sleMplsTpVplsCfgControlDescription OID value, configure state conditions and alerts, and monitor any DASAN Networks SLE OLT, carrier Ethernet / MPLS-TP access switch (VPLS instance/pseudowire status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6296 | dasan | DASAN-DHCP-MIB |
| 1.3.6.1.4.1.6296.101 | sleMgmt | DASAN-SMI |
| 1.3.6.1.4.1.6296.101.16 | sleMpls | SLE-MPLS-TP-BFD-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6296.101.16.16 | sleMplsTpVpls | SLE-MPLS-TP-VPLS-MIB |
| 1.3.6.1.4.1.6296.101.16.16.1 | sleMplsTpVplsCfg | SLE-MPLS-TP-VPLS-MIB |
| 1.3.6.1.4.1.6296.101.16.16.1.2 | sleMplsTpVplsCfgControl | SLE-MPLS-TP-VPLS-MIB |
| 1.3.6.1.4.1.6296.101.16.16.1.2.11 | sleMplsTpVplsCfgControlDescription | SLE-MPLS-TP-VPLS-MIB |