All MIBs › SL-SONET-SUP-PM-MIB › sonetFarEndVTDayFCs
sonetFarEndVTDayFCs
Module: SL-SONET-SUP-PM-MIB
OID (symbolic): SL-SONET-SUP-PM-MIB::sonetFarEndVTDayFCs
OID (numeric): 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4
Node type: OBJECT-TYPE
Type: PerfTotalCount
Access: read-only
Description: The far-end path failure count (FC-VFE) is the number of occurences of far-end path failure events detected by the SONET VT-path layer interface in a previous 1-day interval. A far-end path failure event begins when the first of any remote failure indication (RFI-V, RFI-V server, or RFI-V connectivity) failure is declared; a far-end path failure event ends when all RFI-V, RFI-V server, or RFI-V connectivity failures are cleared.
What is sonetFarEndVTDayFCs?
Count of far-end VT-path failure events (FC-VFE) during the day -- episodes bounded by the first remote failure indication (RFI-V or related server/connectivity RFI-V) being declared and ending when all such indications clear -- reported back by the remote end.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4 snmpwalk -v2c -c public <target> SL-SONET-SUP-PM-MIB::sonetFarEndVTDayFCs
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4.1 snmpget -v2c -c public <target> SL-SONET-SUP-PM-MIB::sonetFarEndVTDayFCs.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sonetFarEndVTDayFCs.1
Start monitoring Smartoptics SONET transport equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-SONET-SUP-PM-MIB::sonetFarEndVTDayFCs OID value, configure state conditions and alerts, and monitor any Smartoptics SONET transport equipment from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4515 | smartoptics | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1 | sitelight | SL-NE-MIB |
| 1.3.6.1.4.1.4515.1.6 | slSonetMib | SL-SONET-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4515.1.6.3 | sonetSupPmMIB | SL-SONET-SUP-PM-MIB |
| 1.3.6.1.4.1.4515.1.6.3.3 | sonetSupObjectsVT | SL-SONET-SUP-PM-MIB |
| 1.3.6.1.4.1.4515.1.6.3.3.2 | sonetSupFarEndVT | SL-SONET-SUP-PM-MIB |
| 1.3.6.1.4.1.4515.1.6.3.3.2.3 | sonetFarEndVTDayTable | SL-SONET-SUP-PM-MIB |
| 1.3.6.1.4.1.4515.1.6.3.3.2.3.1 | sonetFarEndVTDayEntry | SL-SONET-SUP-PM-MIB |
| 1.3.6.1.4.1.4515.1.6.3.3.2.3.1.4 | sonetFarEndVTDayFCs | SL-SONET-SUP-PM-MIB |