SL-SFP-MIB :: sfpConfigMaxTemp

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SL-SFP-MIB › sfpConfigMaxTemp

sfpConfigMaxTemp

Module: SL-SFP-MIB

OID (symbolic): SL-SFP-MIB::sfpConfigMaxTemp

OID (numeric): 1.3.6.1.4.1.4515.1.10.1.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This field defines the maximum operating case temperature the module is rated for. The maximum case temperature is encoded as a signed two�s complement value in �C, yielding a total range of �128C to +127�C. This field should be used even if a standard operating temperature class is indicated in the Extended Indentifier Byte (Byte 1).

What is sfpConfigMaxTemp?

The maximum case operating temperature the module is rated for, in whole degrees Celsius (two's-complement signed value); used to check a module isn't being run outside its thermal spec in a hot equipment room.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4515.1.10.1.1.1.18
snmpwalk -v2c -c public <target> SL-SFP-MIB::sfpConfigMaxTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4515.1.10.1.1.1.18.1
snmpget -v2c -c public <target> SL-SFP-MIB::sfpConfigMaxTemp.1

Start monitoring SmartOptics SiteLight optical transport platform, SFP transceiver module (digital diagnostics/compliance status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL-SFP-MIB::sfpConfigMaxTemp OID value, configure state conditions and alerts, and monitor any SmartOptics SiteLight optical transport platform, SFP transceiver module (digital diagnostics/compliance status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4515smartopticsSL-NE-MIB
1.3.6.1.4.1.4515.1sitelightSL-NE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4515.1.10slSfpSL-SFP-MIB
1.3.6.1.4.1.4515.1.10.1sfpConfSL-SFP-MIB
1.3.6.1.4.1.4515.1.10.1.1sfpConfigTableSL-SFP-MIB
1.3.6.1.4.1.4515.1.10.1.1.1sfpConfigEntrySL-SFP-MIB
1.3.6.1.4.1.4515.1.10.1.1.1.18sfpConfigMaxTempSL-SFP-MIB