| OID symbolic | OID numeric | Type | Access | Description |
| INT esmc1000BaseTRole | 1.3.6.1.4.1.3373.1103.28.17.1.8 | INTEGER | read-create | This object allows to input the clock generator role of a 1000BaseT
interface. This objects is applicable when the quality management
is disabled (timingGeneratorQualityEnable set to off(1)) and to
all interfaces not connected to any timingSink when the quality
management is enabled. |
| C32 esmcPktsRxEx | 1.3.6.1.4.1.3373.1103.28.17.1.4 | Counter32 | read-only | This object contains the total number of received ESMC-PDU packets
on this interface. |
| C32 esmcPktsRxDropped | 1.3.6.1.4.1.3373.1103.28.17.1.6 | Counter32 | read-only | This object contains the total number of dropped ESMC-PDU packets
on this interface. |
| C32 esmcPktsRxErrored | 1.3.6.1.4.1.3373.1103.28.17.1.7 | Counter32 | read-only | This object contains the total number of dropped ESMC-PDU packets
whose processing(decoding) resulted into error. |
| C32 esmcPktsTx | 1.3.6.1.4.1.3373.1103.28.17.1.5 | Counter32 | read-only | This object contains the total number of transmitted ESMC-PDU
packets on this interface. |
| INT esmcQlRx | 1.3.6.1.4.1.3373.1103.28.17.1.2 | INTEGER | read-only | This object show quality received on ESMC-PDU this interface. |
| INT esmcQlTx | 1.3.6.1.4.1.3373.1103.28.17.1.3 | INTEGER | read-only | This object show quality transmitted in ESMC-PDU on this interface. |
| esmcRecord | 1.3.6.1.4.1.3373.1103.28.17.1 | | not-accessible | esmcTable entry.
Every entries describes an ESMC channel of a TE interface. |
| ROW esmcRowStatus | 1.3.6.1.4.1.3373.1103.28.17.1.9 | RowStatus | read-create | Status of this row of esmcTable. |
| INT esmcSsmEnable | 1.3.6.1.4.1.3373.1103.28.17.1.1 | INTEGER | read-create | This object enables SSM messaging on this ifIndex. |
| esmcTable | 1.3.6.1.4.1.3373.1103.28.17 | | not-accessible | Table with TimingSinkSelector records. |
| sync | 1.3.6.1.4.1.3373.1103.28 | | | Timing Source Management. |
| INT syncMibVersion | 1.3.6.1.4.1.3373.1103.28.1 | INTEGER | read-only | Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01. |
| INT timingGeneratorActiveStatus | 1.3.6.1.4.1.3373.1103.28.2.1.11 | INTEGER | read-only | Active status (Probable cause = xxx) with associated severity. |
| INT timingGeneratorActiveStatusSeverityCode | 1.3.6.1.4.1.3373.1103.28.11 | INTEGER | read-write | Defines the severity associated to the timingGeneratorActiveStatus
and enables/disables the trap generation on status change event. |
| I32 timingGeneratorForcedSwitch | 1.3.6.1.4.1.3373.1103.28.6 | Integer32 | read-write | timingGeneratorId of the forced timingGenerator instance.
If no forced timing generator is selected, the value
should be set to 0. |
| ALA timingGeneratorFreeRunningStatus | 1.3.6.1.4.1.3373.1103.28.2.1.9 | AlarmStatus | read-only | Free running status (Probable cause = xxx) with associated severity. |
| ALA timingGeneratorFreeRunningStatusSeverityCode | 1.3.6.1.4.1.3373.1103.28.9 | AlarmSeverityCode | read-write | Defines the severity associated to the timingGeneratorFreeRunningStatus
and enables/disables the trap generation on status change event. |
| INT timingGeneratorHoldOffTime | 1.3.6.1.4.1.3373.1103.28.2.1.3 | INTEGER | read-create | HoldOff time in milliseconds (300..1800). |
| ALA timingGeneratorHoldoverStatus | 1.3.6.1.4.1.3373.1103.28.2.1.10 | AlarmStatus | read-only | Holdover status (Probable cause = xxx) with associated severity. |
| ALA timingGeneratorHoldoverStatusSeverityCode | 1.3.6.1.4.1.3373.1103.28.10 | AlarmSeverityCode | read-write | Defines the severity associated to the timingGeneratorHoldoverStatus
and enables/disables the trap generation on status change event. |
| I32 timingGeneratorId | 1.3.6.1.4.1.3373.1103.28.2.1.1 | Integer32 | read-only | This object is used as Index of the Timing Generator Table. |
| timingGeneratorMaintRecord | 1.3.6.1.4.1.3373.1103.28.3.1 | | not-accessible | TimingGenerator record. |
| timingGeneratorMaintTable | 1.3.6.1.4.1.3373.1103.28.3 | | not-accessible | Table with TimingGenerator records. |
| I32 timingGeneratorManualSwitch | 1.3.6.1.4.1.3373.1103.28.5 | Integer32 | read-write | timingGeneratorId of the forced timingGenerator instance.
If no preferred timing generator is selected, the value
should be set to 0. |
| INT timingGeneratorQualityEnable | 1.3.6.1.4.1.3373.1103.28.12 | INTEGER | read-write | Quality policy enable |
| timingGeneratorRecord | 1.3.6.1.4.1.3373.1103.28.2.1 | | not-accessible | TimingGenerator record. |
| ROW timingGeneratorRowStatus | 1.3.6.1.4.1.3373.1103.28.2.1.17 | RowStatus | read-create | Status of this row of timingGeneratorTable. |
| INT timingGeneratorSinkLosReset | 1.3.6.1.4.1.3373.1103.28.2.1.6 | INTEGER | read-create | Wait time (seconds) before to reset Los of reference signal. |
| INT timingGeneratorSinkLosSet | 1.3.6.1.4.1.3373.1103.28.2.1.5 | INTEGER | read-create | Wait time (seconds) before to set Los of reference signal. |
| INT timingGeneratorStatusControl | 1.3.6.1.4.1.3373.1103.28.3.1.2 | INTEGER | read-write | Clock generator operating mode control.
This item is linked to a manual operation (ManOpRecord) instance. |
| INT timingGeneratorT0CurrentQuality | 1.3.6.1.4.1.3373.1103.28.2.1.12 | INTEGER | read-only | Current quality on T0. |
| OID timingGeneratorT0ForcedSource | 1.3.6.1.4.1.3373.1103.28.3.1.3 | OBJECT IDENTIFIER | read-write | Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as forced clock source of T0.
If no forced timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }. |
| OID timingGeneratorT0PreferredSource | 1.3.6.1.4.1.3373.1103.28.2.1.15 | OBJECT IDENTIFIER | read-create | Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as preferential clock source of T0.
If no preferential timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }. |
| ALA timingGeneratorT0SquelchAlarm | 1.3.6.1.4.1.3373.1103.28.2.1.7 | AlarmStatus | read-only | T0 squelch Alarm (Probable cause = xxx) with associated severity. |
| ALA timingGeneratorT0SquelchAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.28.7 | AlarmSeverityCode | read-write | Defines the severity associated to the TimingGeneratorT0SquelchAlarm
and enables/disables the trap generation on status change event. |
| INT timingGeneratorT4CurrentQuality | 1.3.6.1.4.1.3373.1103.28.2.1.13 | INTEGER | read-only | Current quality on T4. |
| OID timingGeneratorT4ForcedSource | 1.3.6.1.4.1.3373.1103.28.3.1.4 | OBJECT IDENTIFIER | read-write | Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as forced clock source of T4.
If no forced timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }. |
| INT timingGeneratorT4MinimumQuality | 1.3.6.1.4.1.3373.1103.28.2.1.14 | INTEGER | read-create | If the Quality Level of the signal used to derive T4 falls below
timingGeneratorT4MinimumQuality then the output will be squelched.
The value ql-DNU inhibits T4 squelch due to this minimum Quality
Level. This feature is enabled by timingGeneratorT4Squelch when
timingGeneratorQualityEnable is on(2). |
| OID timingGeneratorT4PreferredSource | 1.3.6.1.4.1.3373.1103.28.2.1.16 | OBJECT IDENTIFIER | read-create | Object identifier of the leaf timingSinkGenId of the timingSink
instance selected as preferential clock source of T4.
If no preferential timing sink is selected,
the value should be set to the OBJECT IDENTIFIER { 0 0 }. |
| INT timingGeneratorT4Squelch | 1.3.6.1.4.1.3373.1103.28.3.1.1 | INTEGER | read-write | This object is used to enable/disable T4 squelch. |
| ALA timingGeneratorT4SquelchAlarm | 1.3.6.1.4.1.3373.1103.28.2.1.8 | AlarmStatus | read-only | T4 squelch Alarm (Probable cause = xxx) with associated severity. |
| ALA timingGeneratorT4SquelchAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.28.8 | AlarmSeverityCode | read-write | Defines the severity associated to the timingGeneratorT4SquelchAlarm
and enables/disables the trap generation on status change event. |
| INT timingGeneratorT4vsT0 | 1.3.6.1.4.1.3373.1103.28.2.1.2 | INTEGER | read-create | This object is used to set or reset the condition T4 equal T0. |
| timingGeneratorTable | 1.3.6.1.4.1.3373.1103.28.2 | | not-accessible | Table with TimingGenerator records. |
| OID timingGeneratorWtrClearSource | 1.3.6.1.4.1.3373.1103.28.3.1.5 | OBJECT IDENTIFIER | read-write | Object identifier of the leaf timingSinkGenId of the timingSink
instance selected to clear WTR time. On read, this object return
alvays an OBJECT IDENTIFIER {0 0}. |
| INT timingGeneratorWtrTime | 1.3.6.1.4.1.3373.1103.28.2.1.4 | INTEGER | read-create | Wait Time to Restore in minutes (0..12). |
| INT timingSinkActiveStatus | 1.3.6.1.4.1.3373.1103.28.4.1.10 | INTEGER | read-only | Active status (Probable cause = xxx) status for the reference signal. |
| INT timingSinkActiveStatusSeverityCode | 1.3.6.1.4.1.3373.1103.28.15 | INTEGER | read-write | Defines the severity associated to the timingSinkActiveStatus
and enables/disables the trap generation on status change event. |
| INT timingSinkCurrentQuality | 1.3.6.1.4.1.3373.1103.28.4.1.11 | INTEGER | read-only | Current quality on sink instance. |
| ALA timingSinkDriftAlarm | 1.3.6.1.4.1.3373.1103.28.4.1.9 | AlarmStatus | read-only | Drift of reference signal (Probable cause = xxx) alarm
with associated severity. |
| ALA timingSinkDriftAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.28.14 | AlarmSeverityCode | read-write | Defines the severity associated to the TimingSinkDriftAlarm
and enables/disables the trap generation on status change event. |
| INT timingSinkE1Sabit | 1.3.6.1.4.1.3373.1103.28.4.1.15 | INTEGER | read-create | Specifies the San synchronization status bit used
to indicate the clock quality level.
Meaningful when the Sink source is an E1 |
| INT timingSinkEthPortRole | 1.3.6.1.4.1.3373.1103.28.4.1.16 | INTEGER | read-create | This item configures how to handle the role of a 1000BASE-T port
when it is used as a source of timing: choosing 'static', the
role is set according ethLanPhyTable settings, choosing 'dynamic',
the role is set consistently with the timing direction over the
1000baseT link chosen by SSM protocol. |
| I32 timingSinkGenId | 1.3.6.1.4.1.3373.1103.28.4.1.1 | Integer32 | read-only | This object is used as Index of the timingGeneratorTable and
defines in union with timingSinkType and timingSinkId the
reference signal. |
| I32 timingSinkId | 1.3.6.1.4.1.3373.1103.28.4.1.2 | Integer32 | read-only | This object is used as Index of the timingSinkTable and
defines in union with timingSinkType and timingSinkGenId the
reference signal. |
| NUM timingSinkIfIndex | 1.3.6.1.4.1.3373.1103.28.4.1.4 | InterfaceIndexOrZero | read-only | The ifIndex value the agent selected for this
timingSink interface. |
| STR timingSinkLabel | 1.3.6.1.4.1.3373.1103.28.4.1.7 | DisplayString | read-only | ASCII string used to describe the reference signal when a trap is sent. |
| ALA timingSinkLosAlarm | 1.3.6.1.4.1.3373.1103.28.4.1.8 | AlarmStatus | read-only | Loss of reference signal (Probable cause = xxx) alarm
with associated severity. |
| ALA timingSinkLosAlarmSeverityCode | 1.3.6.1.4.1.3373.1103.28.13 | AlarmSeverityCode | read-write | Defines the severity associated to the TimingSinkLosAlarm
and enables/disables the trap generation on status change event. |
| INT timingSinkOverwriteRxQuality | 1.3.6.1.4.1.3373.1103.28.4.1.13 | INTEGER | read-create | Forcing of Rx quality parameter. |
| INT timingSinkOverwriteTxQuality | 1.3.6.1.4.1.3373.1103.28.4.1.12 | INTEGER | read-create | Forcing of Tx quality parameter. |
| INT timingSinkPriority | 1.3.6.1.4.1.3373.1103.28.4.1.6 | INTEGER | read-create | This object is used to set the priority of the reference signal (p1 is
the highest priority). |
| timingSinkRecord | 1.3.6.1.4.1.3373.1103.28.4.1 | | not-accessible | TimingSink record. |
| ROW timingSinkRowStatus | 1.3.6.1.4.1.3373.1103.28.4.1.17 | RowStatus | read-create | Status of this row of timingSinkTable |
| I32 timingSinkSelector | 1.3.6.1.4.1.3373.1103.28.4.1.5 | Integer32 | read-create | This object is used to select one of the possible clock source
connected to this timingSink. Valid values are listed in
timingSinkSelectorTable: only values of timingSinkSelectorId
related to this instance of timinkSinkRecord are accepted.
Only the values corresponding to the index timingSinkSelectorId of
timinkSinkSelectorTable related to this instance of
timinkSinkRecord will be accepted. |
| I32 timingSinkSelectorId | 1.3.6.1.4.1.3373.1103.28.16.1.1 | Integer32 | read-only | This object is used as Index of the timingSinkSelectorTable and
defines in union with timingSinkGenId, timingSinkType and
timingSinkId the selected source by a multiplexer outside the
SETS. |
| STR timingSinkSelectorLabel | 1.3.6.1.4.1.3373.1103.28.16.1.2 | DisplayString | read-only | ASCII string used to describe the selectable timing source. |
| timingSinkSelectorRecord | 1.3.6.1.4.1.3373.1103.28.16.1 | | not-accessible | TimingSinkSelector entry.
Several instances of this entry can be create for each instance of
timingSinkTable. Each entry represents a possible source selected
by a multiplexer outside the SETS for a specific timingSink.
Only the values corresponding to the index timingSinkSelectorId can
be set to timingSinkSelector. |
| timingSinkSelectorTable | 1.3.6.1.4.1.3373.1103.28.16 | | not-accessible | Table with TimingSinkSelector records. |
| INT timingSinkSentQuality | 1.3.6.1.4.1.3373.1103.28.4.1.14 | INTEGER | read-only | Quality level written in the S1 byte of the outgoing STM-n. |
| timingSinkTable | 1.3.6.1.4.1.3373.1103.28.4 | | not-accessible | Table with TimingSink records. |
| INT timingSinkType | 1.3.6.1.4.1.3373.1103.28.4.1.3 | INTEGER | read-only | This object is used as Index of the timingSinkTable and defines
if the reference signal is used to generate T0 or T4 system clock. |