SIAE-SYNC-MIB :: timingGeneratorSinkLosSet

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSIAE-SYNC-MIBtimingGeneratorSinkLosSet

timingGeneratorSinkLosSet

Module: SIAE-SYNC-MIB

OID (symbolic): SIAE-SYNC-MIB::timingGeneratorSinkLosSet

OID (numeric): 1.3.6.1.4.1.3373.1103.28.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-create

Description: Wait time (seconds) before to set Los of reference signal.

What is timingGeneratorSinkLosSet?

This sets the wait time, in seconds (0-60, default 1), before the system declares Loss of Signal (LOS) on a reference input. An admin raises this value to add debounce time before an LOS alarm is raised on a marginal reference signal.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3373siaeMicroelettronicaSpaSIAE-TREE-MIB
1.3.6.1.4.1.3373.1103siaeMibSIAE-TREE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3373.1103.28syncSIAE-SYNC-MIB
1.3.6.1.4.1.3373.1103.28.2timingGeneratorTableSIAE-SYNC-MIB
1.3.6.1.4.1.3373.1103.28.2.1timingGeneratorRecordSIAE-SYNC-MIB
1.3.6.1.4.1.3373.1103.28.2.1.5timingGeneratorSinkLosSetSIAE-SYNC-MIB