All MIBs › SIAE-SYNC-MIB › timingGeneratorStatusControl
timingGeneratorStatusControl
Module: SIAE-SYNC-MIB
OID (symbolic): SIAE-SYNC-MIB::timingGeneratorStatusControl
OID (numeric): 1.3.6.1.4.1.3373.1103.28.3.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Clock generator operating mode control. This item is linked to a manual operation (ManOpRecord) instance.
What is timingGeneratorStatusControl?
This sets the clock generator's operating mode to freerunning, holdover, or locked (the default), and is linked to a manual operation record. A technician forces this to holdover during a maintenance procedure to keep the clock stable on its last known reference while testing changes elsewhere.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3373.1103.28.3.1.2 snmpwalk -v2c -c public <target> SIAE-SYNC-MIB::timingGeneratorStatusControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3373.1103.28.3.1.2.1 snmpget -v2c -c public <target> SIAE-SYNC-MIB::timingGeneratorStatusControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.3373.1103.28.3.1.2.1 i <value>
Start monitoring SIAE Microelettronica microwave transmission equipment (timing-source selection/holdover status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIAE-SYNC-MIB::timingGeneratorStatusControl OID value, configure state conditions and alerts, and monitor any SIAE Microelettronica microwave transmission equipment (timing-source selection/holdover status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3373 | siaeMicroelettronicaSpa | SIAE-TREE-MIB |
| 1.3.6.1.4.1.3373.1103 | siaeMib | SIAE-TREE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3373.1103.28 | sync | SIAE-SYNC-MIB |
| 1.3.6.1.4.1.3373.1103.28.3 | timingGeneratorMaintTable | SIAE-SYNC-MIB |
| 1.3.6.1.4.1.3373.1103.28.3.1 | timingGeneratorMaintRecord | SIAE-SYNC-MIB |
| 1.3.6.1.4.1.3373.1103.28.3.1.2 | timingGeneratorStatusControl | SIAE-SYNC-MIB |