SHELF-MIB :: boardMissingSev

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSHELF-MIBboardMissingSev

boardMissingSev

Module: SHELF-MIB

OID (symbolic): SHELF-MIB::boardMissingSev

OID (numeric): 1.3.6.1.4.1.1038.150.20.2.1.13

Node type: OBJECT-TYPE

Type: Severity

Access: read-write

Description: A reference to failure severity for boards.

What is boardMissingSev?

The severity level an admin assigns to a 'board missing' failure on this slot, letting a slot that's intentionally left empty (or non-critical) be down-tiered instead of raising a major alarm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1038.150.20.2.1.13
snmpwalk -v2c -c public <target> SHELF-MIB::boardMissingSev

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1038.150.20.2.1.13.1
snmpget -v2c -c public <target> SHELF-MIB::boardMissingSev.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1038.150.20.2.1.13.1 s <value>

Start monitoring SAGEM ADR access/transmission shelf equipment (slot/card inventory and power-feed status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SHELF-MIB::boardMissingSev OID value, configure state conditions and alerts, and monitor any SAGEM ADR access/transmission shelf equipment (slot/card inventory and power-feed status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1038sagemDrSAGEM-DR-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1038.150shelfSHELF-MIB
1.3.6.1.4.1.1038.150.20boardSHELF-MIB
1.3.6.1.4.1.1038.150.20.2boardTableSHELF-MIB
1.3.6.1.4.1.1038.150.20.2.1boardEntrySHELF-MIB
1.3.6.1.4.1.1038.150.20.2.1.13boardMissingSevSHELF-MIB