| OID symbolic | OID numeric | Type | Access | Description |
| dec | 1.3.6.1.4.1.36 | | | |
| ema | 1.3.6.1.4.1.36.2 | | | |
| sysobjids | 1.3.6.1.4.1.36.2.15 | | | |
| raidmanager | 1.3.6.1.4.1.36.2.15.21 | | | |
| NTF diskFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.1 | | | A disk drive has failed. Details: A disk device has failed. User Action: Replace the disk device. |
| NTF diskInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.2 | | | A disk drive has recovered. Details: A disk device has recovered. User Action: None. |
| NTF powerSupplyFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.3 | | | One power supply has failed. Details: The power supply in the specified location has failed. User Action: Replace power supply. |
| NTF powerSupplyInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.4 | | | Power supply has recovered. Details: The power supply in the specified location has gone from BAD to good. User Action: None. |
| NTF fanFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.5 | | | A fan has failed. Details: The fan in the specified location has failed. User Action: Replace fan. |
| NTF fanInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.6 | | | A fan has recovered. Details: The fan in the specified location has recovered. User Action: None. |
| NTF cacheBatteryFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.7 | | | A controller cache battery has failed. Details: The cache battery in specified location has failed. User Action: Replace cache battery or replenish charge. |
| NTF cacheBatteryLowTrap | 1.3.6.1.4.1.36.2.15.21.0.8 | | | A controller cache battery has LOW state. Details: The cache battery in specified location has LOW state. User Action: Replace cache battery or replenish charge. |
| NTF cacheBatteryInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.9 | | | A controller cache battery has good state. Details: The cache battery in specified location has good state. User Action: None. |
| NTF temperatureOverThresholdTrap | 1.3.6.1.4.1.36.2.15.21.0.10 | | | A temperature sensor has exceeded WARNING threshold limit. Details: The temperature sensor in the specified location has exceeded WARNING threshold limit. User Action: Lower environmental temperature or raise internal threshold limit depending upon application. |
| NTF temperatureInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.11 | | | A temperature sensor indicates temperature below WARNING threshold limit. Details: The temperature sensor in the specified location indicates below WARNING threshold limit. User Action: None. |
| NTF communicationFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.12 | | | Communication with the subsystem has failed. Details: The Agent lost communication with subsystem. User Action: Possible causes are data path interruption, communication LUN failure, 2 or more power supplies failed, 2 or more fans failed, temperature overlimit, both controllers failed. |
| NTF communicationInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.13 | | | Communication with the subsystem has recovered. Details: The Agent recovered communication with subsystem. User Action: None. |
| NTF controllerFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.14 | | | The Secondary Controller in the subsytem has failed. Details: The Secondary Controller has failed. User Action: Replace controller. Possible causes are PCMCIA memory card ejected, controller physically removed, actual hardware failure. |
| NTF controllerInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.15 | | | The Secondary Controller in the subsytem has recovered. Details: The Secondary Controller has recovered. User Action: None. |
| NTF lunFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.16 | | | A LUN has failed. Details: The LUN has failed and is off-line. User Action: Possible cause is too many failed disk drives that make up the LUN, the OS can no longer communicate with the LUN for other reasons. |
| NTF lunReconstructTrap | 1.3.6.1.4.1.36.2.15.21.0.17 | | | A LUN has started the reconstruction process. Details: The LUN has started the reconstruction process but is available for normal use. Possible causes are an available disk drive was created as a spare to be inserted into the set, an existing spare was automatically added to the set for reconstruction upon failure of a member disk device. User Action: None. |
| NTF lunReducedTrap | 1.3.6.1.4.1.36.2.15.21.0.18 | | | A LUN has become degraded. Details: A LUN has become degraded due to a member disk device failure. User Action: Replace the failed disk device; add a spare to the system to cause a reconstruct. |
| NTF lunInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.19 | | | A LUN has become optimal. Details: A LUN has become optimal due to a successful completion of the reconstruction process. User Action: None. |
| NTF externalInputFailureTrap | 1.3.6.1.4.1.36.2.15.21.0.20 | | | The user-defined External Input to the EMU indicates a failure. Details: The External Input to the EMU indicates a failure. User Action: If the state of the is FAILURE, then one of the user-defined external input devices is reporting a problem. |
| NTF externalInputInformationTrap | 1.3.6.1.4.1.36.2.15.21.0.21 | | | The user-defined External Input to the EMU indicates a recovery. Details: The External Input to the EMU indicates a recovery. User Action: None. |
| NTF cacheBatteryStateUnknownTrap | 1.3.6.1.4.1.36.2.15.21.0.22 | | | A controller cache battery has unknown state. Details: The cache battery in specified location has an unknown state. User Action: None. |
| agent | 1.3.6.1.4.1.36.2.15.21.1 | | | |
| STR agManufacturer | 1.3.6.1.4.1.36.2.15.21.1.1 | DisplayString | read-only | The name of the Enterprise Storage Manager Agent manufacturer. |
| INT agMajVersion | 1.3.6.1.4.1.36.2.15.21.1.2 | INTEGER | read-only | Enterprise Storage Manager Agent Major Version Number (e.g., 3
for 3.0). |
| INT agMinVersion | 1.3.6.1.4.1.36.2.15.21.1.3 | INTEGER | read-only | Enterprise Storage Manager Agent Minor Version Number (e.g., 0
for 3.0). |
| STR agHostName | 1.3.6.1.4.1.36.2.15.21.1.4 | DisplayString | read-only | The Host System Network Name where the agent resides. |
| OID agEnterprise | 1.3.6.1.4.1.36.2.15.21.1.5 | OBJECT IDENTIFIER | read-only | The Enterprise ID subtree for Enterprise Storage Manager Agent MIB
is registered. |
| STR agDescription | 1.3.6.1.4.1.36.2.15.21.1.6 | DisplayString | read-only | The Enterprise Array Storage Agent description. |
| workstation | 1.3.6.1.4.1.36.2.15.21.2 | | | |
| STR wsCPU | 1.3.6.1.4.1.36.2.15.21.2.1 | DisplayString | read-only | The workstation CPU type (e.g., 80486). |
| STR wsComputerType | 1.3.6.1.4.1.36.2.15.21.2.2 | DisplayString | read-only | The workstation Computer type (e.g., PC/AT). |
| INT wsModel | 1.3.6.1.4.1.36.2.15.21.2.3 | INTEGER | read-only | The workstation model number. |
| INT wsSubModel | 1.3.6.1.4.1.36.2.15.21.2.4 | INTEGER | read-only | The workstation submodel number. |
| STR wsBiosVersion | 1.3.6.1.4.1.36.2.15.21.2.5 | DisplayString | read-only | The workstation BIOS Version. |
| STR wsOS | 1.3.6.1.4.1.36.2.15.21.2.6 | DisplayString | read-only | The workstation operating system name (e.g., WINNT). |
| INT wsOSMajVersion | 1.3.6.1.4.1.36.2.15.21.2.7 | INTEGER | read-only | The workstation OS major version number
(e.g., 3 for WINNT 3.51). |
| INT wsOSMinVersion | 1.3.6.1.4.1.36.2.15.21.2.8 | INTEGER | read-only | The workstation OS minor version number (e.g., 51 for
WINNT 3.51). |
| subsys | 1.3.6.1.4.1.36.2.15.21.3 | | | |
| INT ssTotalSubSystems | 1.3.6.1.4.1.36.2.15.21.3.1 | INTEGER | read-only | The total number of subsystems presently serviced
by this agent. |
| ssStatusTable | 1.3.6.1.4.1.36.2.15.21.3.2 | | not-accessible | This table holds the status information for
each subsystem. |
| ssEntry | 1.3.6.1.4.1.36.2.15.21.3.2.1 | | not-accessible | The subsystem information entry. |
| INT ssEntryIndex | 1.3.6.1.4.1.36.2.15.21.3.2.1.1 | INTEGER | read-only | The index into ssStatusTable . |
| STR ssSubsysName | 1.3.6.1.4.1.36.2.15.21.3.2.1.2 | DisplayString | read-only | The local Subsystem Name. |
| INT ssOverallStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.3 | INTEGER | read-only | This variable reports the overall status of the
storage subsystem.
GREEN: Normal Operating Condition
YELLOW: Warning Condition
RED: Subsystem Communication Failure; No response to Agent requests. |
| INT ssDiskStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.4 | INTEGER | read-only | This variable reports the overall status for the
physical devices in the subsystem. |
| INT ssPowerStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.5 | INTEGER | read-only | This variable reports the status for the
Power Supply system in the subsystem. |
| INT ssFanStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.6 | INTEGER | read-only | This variable reports the status for the
FAN system in the subsystem. |
| INT ssCacheBatteryStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.7 | INTEGER | read-only | This variable reports the status for the
Cache Battery in the subsystem. This status object is currently
non-functional but in place for future use. |
| INT ssTemperatureStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.8 | INTEGER | read-only | This variable reports the status for the
Temperature in the subsystem. |
| INT ssCommStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.9 | INTEGER | read-only | This variable reports the status for the
communication to the Primary Controller. |
| INT ssEmuExtInputStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.10 | INTEGER | read-only | This variable reports the status for the
EMU external input. |
| INT ssEmuPresent | 1.3.6.1.4.1.36.2.15.21.3.2.1.11 | INTEGER | read-only | This variable reports the availability of the
Environment Monitoring Unit for the storage subsystem. |
| INT ssController1Status | 1.3.6.1.4.1.36.2.15.21.3.2.1.12 | INTEGER | read-only | This variable reports the status for the
Primary Controller. |
| STR ssController1SerNum | 1.3.6.1.4.1.36.2.15.21.3.2.1.13 | DisplayString | read-only | The Primary Controller's Serial Number. |
| INT ssController1RDAC | 1.3.6.1.4.1.36.2.15.21.3.2.1.14 | INTEGER | read-only | The Primary Controller MODE. |
| STR ssController1Type | 1.3.6.1.4.1.36.2.15.21.3.2.1.15 | DisplayString | read-only | The Primary Controller's Type indicator. |
| STR ssController1ProdID | 1.3.6.1.4.1.36.2.15.21.3.2.1.16 | DisplayString | read-only | The Primary Controller's Product ID. |
| STR ssController1FwRev | 1.3.6.1.4.1.36.2.15.21.3.2.1.17 | DisplayString | read-only | The Primary Controller's Firmware Revision. |
| STR ssController1HwRev | 1.3.6.1.4.1.36.2.15.21.3.2.1.18 | DisplayString | read-only | The Primary Controller's Hardware Revision. |
| INT ssController2Status | 1.3.6.1.4.1.36.2.15.21.3.2.1.19 | INTEGER | read-only | This variable reports the status for the
Secondary Controller. |
| STR ssController2SerNum | 1.3.6.1.4.1.36.2.15.21.3.2.1.20 | DisplayString | read-only | The Secondary Controller's Serial Number. |
| INT ssController2RDAC | 1.3.6.1.4.1.36.2.15.21.3.2.1.21 | INTEGER | read-only | The Secondary Controller MODE. |
| STR ssController2Type | 1.3.6.1.4.1.36.2.15.21.3.2.1.22 | DisplayString | read-only | The Secondary Controller's Type indicator. |
| STR ssController2ProdID | 1.3.6.1.4.1.36.2.15.21.3.2.1.23 | DisplayString | read-only | The Secondary Controller's Product ID. |
| STR ssController2FwRev | 1.3.6.1.4.1.36.2.15.21.3.2.1.24 | DisplayString | read-only | The Secondary Controller's Firmware Revision. |
| STR ssController2HwRev | 1.3.6.1.4.1.36.2.15.21.3.2.1.25 | DisplayString | read-only | The Secondary Controller's Hardware Revision. |
| INT ssUpsStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.26 | INTEGER | read-only | Uninterruptable Power Supply status (Currently for future use). |
| INT ssLunStatus | 1.3.6.1.4.1.36.2.15.21.3.2.1.27 | INTEGER | read-only | LUN status. |
| STR ssDiskName | 1.3.6.1.4.1.36.2.15.21.3.2.1.28 | DisplayString | read-only | The name of disk with state change. |
| STR ssPowerSupplyLocation | 1.3.6.1.4.1.36.2.15.21.3.2.1.29 | DisplayString | read-only | The location of power supply with state change. |
| STR ssFanLocation | 1.3.6.1.4.1.36.2.15.21.3.2.1.30 | DisplayString | read-only | The location of fan with state change. |
| STR ssCacheBatteryLocation | 1.3.6.1.4.1.36.2.15.21.3.2.1.31 | DisplayString | read-only | The location of controller cache battery with state change. |
| STR ssTemperatureSensorLocation | 1.3.6.1.4.1.36.2.15.21.3.2.1.32 | DisplayString | read-only | The location of temperature sensor with state change. |
| INT ssCabinetNumber | 1.3.6.1.4.1.36.2.15.21.3.2.1.33 | INTEGER | read-only | The current cabinet number which has FRU state change. |
| STR ssLunName | 1.3.6.1.4.1.36.2.15.21.3.2.1.34 | DisplayString | read-only | The name of the LUN with a state change. |
| INT ssDiskPort | 1.3.6.1.4.1.36.2.15.21.3.2.1.35 | INTEGER | read-only | The current disk channel number. |
| INT ssDiskTarget | 1.3.6.1.4.1.36.2.15.21.3.2.1.36 | INTEGER | read-only | The current disk SCSI Target ID. |