OMNI-gx2Dm870-MIB :: trapDM870RFInputAlarm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › OMNI-gx2Dm870-MIB › trapDM870RFInputAlarm

trapDM870RFInputAlarm

Module: OMNI-gx2Dm870-MIB

OID (symbolic): OMNI-gx2Dm870-MIB::trapDM870RFInputAlarm

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.16.0.19

Node type: NOTIFICATION-TYPE

Description: This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' OMNI-gx2Dm870-MIB::trapDM870RFInputAlarm
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.1166.6.1.2.16.0.19

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:57410->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (249340994) 28 days, 20:36:49.94
  SNMPv2-MIB::snmpTrapOID.0 = OID: OMNI-gx2Dm870-MIB::trapDM870RFInputAlarm

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (gx2Dm870 RF/optical monitoring probe module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2Dm870-MIB::trapDM870RFInputAlarm OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (gx2Dm870 RF/optical monitoring probe module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.16gx2Dm870GX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.16.0.19trapDM870RFInputAlarmOMNI-gx2Dm870-MIB