OMNI-gx2Dm870-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI IpAddress, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 sysUpTime, DisplayString FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215 gi, motproxies FROM NLS-BBNIDENT-MIB gx2Dm870 FROM GX2HFC-MIB trapIdentifier,trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapNETrapLastTrapTimeStamp, trapChangedObjectId, trapChangedValueInteger, trapChangedValueDisplayString FROM NLSBBN-TRAPS-MIB; -- This MIB module uses the extended OBJECT-TYPE macro as -- defined in RFC1212 and the TRAP-TYPE macro as defined -- in RFC 1215. --REVISION "0" Sept 1, 2003 --DESCRIPTION -- Added revision and description comment section -- OMNISTAR DM 1550 Laser Module (Forward Path Transmetter) MIB MODULE -- This MIB module defines information for management of HFC networks -- -- The MIB module assumes that all generic (static) network element -- information is defined in a different module such as the HFC module -- The MIB consists of two groups: -- the device type descriptor subgroup and -- gx2Dm870 Network Elements subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm870 device type. -- These parameters are common across all network elements -- from gx2Dm870 device type. -- -- The gx2Dm870 Network Elements subgroup is -- a list of gx2Dm870 type elements in the -- current network topology with nominal -- and current parameter values for the -- individual network elements; the individual -- network elements are identified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Dm870TableIndex are equal for each individual -- network element. -- This table is an extension of the hfcCommonTable -- for all elements of gx2Dm870 type. -- -- Both groups are mandatory for management of gx2Dm870 devices. -- **************************************************************************** -- -- All floating point numbers will be represented by an IEEE 32 Bit number. -- Conversion of this number must be done on the user interface to view the -- actual floating point number. -- Float ::= Counter -- UNSIGNED (32 BITS) -- **************************************************************************** -- gx2Dm870 Device Descriptor subgroup. -- The device type descriptor subgroup is used to define -- parameters specific to gx2Dm870 device type. -- These parameters are common across all network elements -- from gx2Dm870 device type. gx2Dm870Descriptor OBJECT IDENTIFIER ::= {gx2Dm870 1} --***************************************************************************** -- gx2Dm870 Table -- Contains a list of all gx2Dm870 type devices in -- the network. Each device is characterized with -- current network topology information, with nominal -- and current parameter values for the -- individual network elements; -- -- The individual network elements indentified by -- index from hfcCommonTable. -- That implies what hfcCommonTableIndex and -- gx2Dm870TableIndex are equal for each individual -- nettwork element. -- This table should be used as an extension of the hfcCommonTable -- for all elements of gx2Dm870 type. gx2Dm870AnalogTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm870AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm870 specific parameters with nominal and current values." ::= { gx2Dm870 2 } gx2Dm870AnalogEntry OBJECT-TYPE SYNTAX Gx2Dm870AnalogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains the analog parameters and descriptions." INDEX { gx2Dm870AnalogTableIndex } ::= { gx2Dm870AnalogTable 1} --************************************************************************* gx2Dm870DigitalTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm870DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm870m specific parameters with nominal and current values." ::= { gx2Dm870 3 } gx2Dm870DigitalEntry OBJECT-TYPE SYNTAX Gx2Dm870DigitalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains digital parameters and descriptions." INDEX { gx2Dm870DigitalTableIndex } ::= { gx2Dm870DigitalTable 2} --************************************************************************* gx2Dm870StatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm870StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm870 specific parameters with nominal and current values." ::= { gx2Dm870 4 } gx2Dm870StatusEntry OBJECT-TYPE SYNTAX Gx2Dm870StatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Status parameters and descriptions." INDEX { gx2Dm870StatusTableIndex } ::= { gx2Dm870StatusTable 3} --************************************************************************* gx2Dm870FactoryTable OBJECT-TYPE SYNTAX SEQUENCE OF Gx2Dm870FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains gx2Dm870 specific parameters with nominal and current values." ::= { gx2Dm870 5 } gx2Dm870FactoryEntry OBJECT-TYPE SYNTAX Gx2Dm870FactoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list contains Factory parameters and descriptions." INDEX { gx2Dm870FactoryTableIndex } ::= { gx2Dm870FactoryTable 4} --************************************************************************* Gx2Dm870AnalogEntry ::= SEQUENCE { gx2Dm870AnalogTableIndex INTEGER, -- Analog Parameters dm870labelOffsetNomMonitor DisplayString (SIZE (0..80)), dm870uomOffsetNomMonitor DisplayString (SIZE (0..80)), dm870majorHighOffsetNomMonitor Float, dm870majorLowOffsetNomMonitor Float, dm870minorHighOffsetNomMonitor Float, dm870minorLowOffsetNomMonitor Float, dm870currentValueOffsetNomMonitor Float, dm870stateFlagOffsetNomMonitor INTEGER, dm870minValueOffsetNomMonitor Float, dm870maxValueOffsetNomMonitor Float, dm870alarmStateOffsetNomMonitor INTEGER, dm870labelOffsetNomCnt DisplayString (SIZE (0..80)), dm870uomOffsetNomCnt DisplayString (SIZE (0..80)), dm870majorHighOffsetNomCnt Float, dm870majorLowOffsetNomCnt Float, dm870minorHighOffsetNomCnt Float, dm870minorLowOffsetNomCnt Float, dm870currentValueOffsetNomCnt Float, dm870stateFlagOffsetNomCnt INTEGER, dm870minValueOffsetNomCnt Float, dm870maxValueOffsetNomCnt Float, dm870alarmStateOffsetNomCnt INTEGER, dm870labelAttenSetting DisplayString (SIZE (0..80)), dm870uomAttenSetting DisplayString (SIZE (0..80)), dm870majorHighAttenSetting Float, dm870majorLowAttenSetting Float, dm870minorHighAttenSetting Float, dm870minorLowAttenSetting Float, dm870currentValueAttenSetting Float, dm870stateFlagAttenSetting INTEGER, dm870minValueAttenSetting Float, dm870maxValueAttenSetting Float, dm870alarmStateAttenSetting INTEGER, dm870labelLaserPower DisplayString (SIZE (0..80)), dm870uomLaserPower DisplayString (SIZE (0..80)), dm870majorHighLaserPower Float, dm870majorLowLaserPower Float, dm870minorHighLaserPower Float, dm870minorLowLaserPower Float, dm870currentValueLaserPower Float, dm870stateFlagLaserPower INTEGER, dm870minValueLaserPower Float, dm870maxValueLaserPower Float, dm870alarmStateLaserPower INTEGER, dm870labelLaserTemp DisplayString (SIZE (0..80)), dm870uomLaserTemp DisplayString (SIZE (0..80)), dm870majorHighLaserTemp Float, dm870majorLowLaserTemp Float, dm870minorHighLaserTemp Float, dm870minorLowLaserTemp Float, dm870currentValueLaserTemp Float, dm870stateFlagLaserTemp INTEGER, dm870minValueLaserTemp Float, dm870maxValueLaserTemp Float, dm870alarmStateLaserTemp INTEGER, dm870labelLaserCurrent DisplayString (SIZE (0..80)), dm870uomLaserCurrent DisplayString (SIZE (0..80)), dm870majorHighLaserCurrent Float, dm870majorLowLaserCurrent Float, dm870minorHighLaserCurrent Float, dm870minorLowLaserCurrent Float, dm870currentValueLaserCurrent Float, dm870stateFlagLaserCurrent INTEGER, dm870minValueLaserCurrent Float, dm870maxValueLaserCurrent Float, dm870alarmStateLaserCurrent INTEGER, dm870labelTecCurrent DisplayString (SIZE (0..80)), dm870uomTecCurrent DisplayString (SIZE (0..80)), dm870majorHighTecCurrent Float, dm870majorLowTecCurrent Float, dm870minorHighTecCurrent Float, dm870minorLowTecCurrent Float, dm870currentValueTecCurrent Float, dm870stateFlagTecCurrent INTEGER, dm870minValueTecCurrent Float, dm870maxValueTecCurrent Float, dm870alarmStateTecCurrent INTEGER, dm870labelModTemp DisplayString (SIZE (0..80)), dm870uomModTemp DisplayString (SIZE (0..80)), dm870majorHighModTemp Float, dm870majorLowModTemp Float, dm870minorHighModTemp Float, dm870minorLowModTemp Float, dm870currentValueModTemp Float, dm870stateFlagModTemp INTEGER, dm870minValueModTemp Float, dm870maxValueModTemp Float, dm870alarmStateModTemp INTEGER, dm870labelFanCurrent DisplayString (SIZE (0..80)), dm870uomFanCurrent DisplayString (SIZE (0..80)), dm870majorHighFanCurrent Float, dm870majorLowFanCurrent Float, dm870minorHighFanCurrent Float, dm870minorLowFanCurrent Float, dm870currentValueFanCurrent Float, dm870stateFlagFanCurrent INTEGER, dm870minValueFanCurrent Float, dm870maxValueFanCurrent Float, dm870alarmStateFanCurrent INTEGER } -- **************** Digital Parameters *********************** Gx2Dm870DigitalEntry ::= SEQUENCE { gx2Dm870DigitalTableIndex INTEGER, dm870labelRfInput DisplayString (SIZE (0..80)), dm870enumRfInput DisplayString (SIZE (0..80)), dm870valueRfInput INTEGER, dm870stateflagRfInput INTEGER, dm870labelOptOutput DisplayString (SIZE (0..80)), dm870enumOptOutput DisplayString (SIZE (0..80)), dm870valueOptOutput INTEGER, dm870stateflagOptOutput INTEGER, dm870labelSbsControl DisplayString (SIZE (0..80)), dm870enumSbsControl DisplayString (SIZE (0..80)), dm870valueSbsControl INTEGER, dm870stateflagSbsControl INTEGER, dm870labelLaserMode DisplayString (SIZE (0..80)), dm870enumLaserMode DisplayString (SIZE (0..80)), dm870valueLaserMode INTEGER, dm870stateflagLaserMode INTEGER, dm870labelFactoryDefault DisplayString (SIZE (0..80)), dm870enumFactoryDefault DisplayString (SIZE (0..80)), dm870valueFactoryDefault INTEGER, dm870stateflagFactoryDefault INTEGER } -- **************** Status Parameters ************************************ Gx2Dm870StatusEntry ::= SEQUENCE { gx2Dm870StatusTableIndex INTEGER, dm870labelBoot DisplayString (SIZE (0..80)), dm870valueBoot INTEGER, dm870stateflagBoot INTEGER, dm870labelFlash DisplayString (SIZE (0..80)), dm870valueFlash INTEGER, dm870stateflagFlash INTEGER, dm870labelFactoryDataCRC DisplayString (SIZE (0..80)), dm870valueFactoryDataCRC INTEGER, dm870stateflagFactoryDataCRC INTEGER, dm870labelLaserDataCRC DisplayString (SIZE (0..80)), dm870valueLaserDataCRC INTEGER, dm870stateflagLaserDataCRC INTEGER, dm870labelAlarmDataCrc DisplayString (SIZE (0..80)), dm870valueAlarmDataCrc INTEGER, dm870stateflagAlarmDataCrc INTEGER, dm870labelRFInputStatus DisplayString (SIZE (0..80)), dm870valueRFInputStatus INTEGER, dm870stateflagRFInputStatus INTEGER } -- **************** Factory Parameters ************************************* Gx2Dm870FactoryEntry ::= SEQUENCE { gx2Dm870FactoryTableIndex INTEGER, dm870bootControlByte INTEGER, dm870bootStatusByte INTEGER, dm870bank1CRC INTEGER, dm870bank2CRC INTEGER, dm870prgEEPROMByte INTEGER, dm870factoryCRC INTEGER, dm870calculateCRC INTEGER, dm870hourMeter INTEGER, dm870flashPrgCntA INTEGER, dm870flashPrgCntB INTEGER, dm870flashBankARev DisplayString (SIZE (0..80)), dm870flashBankBRev DisplayString (SIZE (0..80)) } -- ************** Analog Parameters **************************** gx2Dm870AnalogTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm870AnalogEntry 1} -- New Parameter dm870labelOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Monitor Analog parameter." ::= { gx2Dm870AnalogEntry 2} dm870uomOffsetNomMonitor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter." ::= { gx2Dm870AnalogEntry 3} dm870majorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 4} dm870majorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 5} dm870minorHighOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 6} dm870minorLowOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 7} dm870currentValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Monitor Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 8} dm870stateFlagOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Monitor Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 9} dm870minValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 10} dm870maxValueOffsetNomMonitor OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 11} dm870alarmStateOffsetNomMonitor OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter." ::= { gx2Dm870AnalogEntry 12} -- New Parameter dm870labelOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Offset Control Analog parameter." ::= { gx2Dm870AnalogEntry 13} dm870uomOffsetNomCnt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Offset Control Analog parameter.." ::= { gx2Dm870AnalogEntry 14} dm870majorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 15} dm870majorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 16} dm870minorHighOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 17} dm870minorLowOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 18} dm870currentValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 19} dm870stateFlagOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 20} dm870minValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 21} dm870maxValueOffsetNomCnt OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 22} dm870alarmStateOffsetNomCnt OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the curent alarm state of the Offset Control Analog parameter." ::= { gx2Dm870AnalogEntry 23} -- New Parameter dm870labelAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Attenuator Setting Current Analog parameter." ::= { gx2Dm870AnalogEntry 24} dm870uomAttenSetting OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter." ::= { gx2Dm870AnalogEntry 25} dm870majorHighAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 26} dm870majorLowAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 27} dm870minorHighAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 28} dm870minorLowAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 29} dm870currentValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 30} dm870stateFlagAttenSetting OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 31} dm870minValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 32} dm870maxValueAttenSetting OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 33} dm870alarmStateAttenSetting OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter." ::= { gx2Dm870AnalogEntry 34} -- New Parameter dm870labelLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Optical Power Analog parameter." ::= { gx2Dm870AnalogEntry 35} dm870uomLaserPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter." ::= { gx2Dm870AnalogEntry 36} dm870majorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 37} dm870majorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 38} dm870minorHighLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 39} dm870minorLowLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 40} dm870currentValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 41} dm870stateFlagLaserPower OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 42} dm870minValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 43} dm870maxValueLaserPower OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 44} dm870alarmStateLaserPower OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter." ::= { gx2Dm870AnalogEntry 45} -- New Parameter dm870labelLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Temperature Analog parameter." ::= { gx2Dm870AnalogEntry 46} dm870uomLaserTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.." ::= { gx2Dm870AnalogEntry 47} dm870majorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 48} dm870majorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 49} dm870minorHighLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 50} dm870minorLowLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 51} dm870currentValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 52} dm870stateFlagLaserTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 53} dm870minValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 54} dm870maxValueLaserTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 55} dm870alarmStateLaserTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Temperature Analog parameter." ::= { gx2Dm870AnalogEntry 56} -- New Parameter dm870labelLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Bias Current Analog parameter." ::= { gx2Dm870AnalogEntry 57} dm870uomLaserCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter." ::= { gx2Dm870AnalogEntry 58} dm870majorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 59} dm870majorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 60} dm870minorHighLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 61} dm870minorLowLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 62} dm870currentValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Laser Bias Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 63} dm870stateFlagLaserCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Laser Bias Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 64} dm870minValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 65} dm870maxValueLaserCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 66} dm870alarmStateLaserCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter." ::= { gx2Dm870AnalogEntry 67} -- New Parameter dm870labelTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the TEC Current Analog parameter." ::= { gx2Dm870AnalogEntry 68} dm870uomTecCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the TEC Current Analog parameter." ::= { gx2Dm870AnalogEntry 69} dm870majorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 70} dm870majorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 71} dm870minorHighTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 72} dm870minorLowTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 73} dm870currentValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 74} dm870stateFlagTecCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 75} dm870minValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 76} dm870maxValueTecCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 77} dm870alarmStateTecCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the TEC Current Analog parameter." ::= { gx2Dm870AnalogEntry 78} -- New Parameter dm870labelModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Module Temperature Analog parameter." ::= { gx2Dm870AnalogEntry 79} dm870uomModTemp OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Module Temperature Analog parameter." ::= { gx2Dm870AnalogEntry 80} dm870majorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 81} dm870majorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 82} dm870minorHighModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 83} dm870minorLowModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 84} dm870currentValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 85} dm870stateFlagModTemp OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 86} dm870minValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 87} dm870maxValueModTemp OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 88} dm870alarmStateModTemp OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Module Temperature Analog parameter." ::= { gx2Dm870AnalogEntry 89} -- New Parameter dm870labelFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Fan Current Analog parameter." ::= { gx2Dm870AnalogEntry 90} dm870uomFanCurrent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the Unit of Measure of the Fan Current Analog parameter." ::= { gx2Dm870AnalogEntry 91} dm870majorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 92} dm870majorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 93} dm870minorHighFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 94} dm870minorLowFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS obsolete DESCRIPTION "The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. All F's indicate the parameter is unused" ::= { gx2Dm870AnalogEntry 95} dm870currentValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 96} dm870stateFlagFanCurrent OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870AnalogEntry 97} dm870minValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 98} dm870maxValueFanCurrent OBJECT-TYPE SYNTAX Float ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number." ::= { gx2Dm870AnalogEntry 99} dm870alarmStateFanCurrent OBJECT-TYPE SYNTAX INTEGER { noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the curent alarm state of the Fan Current Analog parameter." ::= { gx2Dm870AnalogEntry 100} -- ************************ Digital parameters ********************************** gx2Dm870DigitalTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm870DigitalEntry 1} -- New parameter dm870labelRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the RF Input Control Digital parameter." ::= { gx2Dm870DigitalEntry 2} dm870enumRfInput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm870DigitalEntry 3} dm870valueRfInput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm870DigitalEntry 4} dm870stateflagRfInput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870DigitalEntry 5} -- New parameter dm870labelOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Optical Output Control Digital parameter." ::= { gx2Dm870DigitalEntry 6} dm870enumOptOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm870DigitalEntry 7} dm870valueOptOutput OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm870DigitalEntry 8} dm870stateflagOptOutput OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870DigitalEntry 9} -- New parameter dm870labelSbsControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the SBS Control Digital parameter." ::= { gx2Dm870DigitalEntry 10} dm870enumSbsControl OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm870DigitalEntry 11} dm870valueSbsControl OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm870DigitalEntry 12} dm870stateflagSbsControl OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870DigitalEntry 13} -- New parameter dm870labelLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Mode Digital parameter." ::= { gx2Dm870DigitalEntry 14} dm870enumLaserMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1." ::= { gx2Dm870DigitalEntry 15} dm870valueLaserMode OBJECT-TYPE SYNTAX INTEGER { preset(1), set(2), setEquate(3), manual(4), manualEquate(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter." ::= { gx2Dm870DigitalEntry 16} dm870stateflagLaserMode OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870DigitalEntry 17} -- New parameter dm870labelFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Default Digital parameter." ::= { gx2Dm870DigitalEntry 18} dm870enumFactoryDefault OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.." ::= { gx2Dm870DigitalEntry 19} dm870valueFactoryDefault OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object is the current value of the parameter. Return value is meaningless" ::= { gx2Dm870DigitalEntry 20} dm870stateflagFactoryDefault OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870DigitalEntry 21} -- *********** STATUS ***************** gx2Dm870StatusTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm870StatusEntry 1} --New Parameter dm870labelBoot OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Boot Status Status parameter." ::= { gx2Dm870StatusEntry 2} dm870valueBoot OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 3} dm870stateflagBoot OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 4} --New Parameter dm870labelFlash OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Flash Status Status parameter." ::= { gx2Dm870StatusEntry 5} dm870valueFlash OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 6} dm870stateflagFlash OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 7} --New Parameter dm870labelFactoryDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Factory Data CRC Status parameter." ::= { gx2Dm870StatusEntry 8} dm870valueFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 9} dm870stateflagFactoryDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 10} --New Parameter dm870labelLaserDataCRC OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Laser Data CRC Status parameter." ::= { gx2Dm870StatusEntry 11} dm870valueLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 12} dm870stateflagLaserDataCRC OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 13} --New Parameter dm870labelAlarmDataCrc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2Dm870StatusEntry 14} dm870valueAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 15} dm870stateflagAlarmDataCrc OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 16} --New Parameter dm870labelRFInputStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS optional DESCRIPTION "The value of this object provides the label of the Alarm Data Crc parameter." ::= { gx2Dm870StatusEntry 17} dm870valueRFInputStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical)." ::= { gx2Dm870StatusEntry 18} dm870stateflagRFInputStatus OBJECT-TYPE SYNTAX INTEGER { hidden(1), read-only(2), updateable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable)." ::= { gx2Dm870StatusEntry 19} -- ************ FACTORY DATA **************** gx2Dm870FactoryTableIndex OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element." ::= { gx2Dm870FactoryEntry 1} dm870bootControlByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object indicates which bank the firmware is currently being boot from." ::= { gx2Dm870FactoryEntry 2} dm870bootStatusByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail)" ::= { gx2Dm870FactoryEntry 3} dm870bank1CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 0. The display formate for the data is Hex." ::= { gx2Dm870FactoryEntry 4} dm870bank2CRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code of bank 1.The display formate for the data is Hex." ::= { gx2Dm870FactoryEntry 5} dm870prgEEPROMByte OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the EEPROM has been programmed" ::= { gx2Dm870FactoryEntry 6} dm870factoryCRC OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the CRC code for the Factory data." ::= { gx2Dm870FactoryEntry 7} dm870calculateCRC OBJECT-TYPE SYNTAX INTEGER { factory(1), na(2), alarm(3) } ACCESS read-only STATUS obsolete DESCRIPTION "This object indicates which of the Enums will have the CRC calculated." ::= { gx2Dm870FactoryEntry 8} dm870hourMeter OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the hour meter reading of the module." ::= { gx2Dm870FactoryEntry 9} dm870flashPrgCntA OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Dm870FactoryEntry 10} dm870flashPrgCntB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the number of times Bank 1 flash has been programmed." ::= { gx2Dm870FactoryEntry 11} dm870flashBankARev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 0. The rev is 2 characters." ::= { gx2Dm870FactoryEntry 12} dm870flashBankBRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides the revision of flash bank 1. The rev is 2 characters." ::= { gx2Dm870FactoryEntry 13} -- **************************************************************** -- -- TRAP DEFINITIONS -- -- -- Every trap generated by an HFC agents will include first 9 identical -- fields. If particular variable is not supported in -- particular TRAP-TYPE then default value will be returned. -- -- DESCRIPTION will include explanation of use of generic -- variables (trapAdditionalInfo******.) If no -- DESCRIPTION is given then generic variables will contain -- default values. -- -- ***************************************************************** --*************************************************************************** -- ***********!!! THE TRAP SECTION HAS NOT BEEN COMPLETED YET !!! *********** --*************************************************************************** -- ************************************************************************** -- DM870 Module traps -- ************************************************************************** trapDM870ConfigChangeInteger TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 1 trapDM870ConfigChangeDisplayString TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueDisplayString, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'" ::= 2 trapDM870fanCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 3 trapDM870ModuleTempAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 4 trapDM870omiOffsetAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the OMI Offset goes out of range." ::= 5 trapDM870tecCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 6 trapDM870LaserCurrentAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 7 trapDM870LaserTempAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 8 trapDM870LaserPowerAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 9 trapDM870FlashAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error during Flash memory operations." ::= 10 trapDM870BankBootAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1." ::= 11 trapDM870AlarmDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Alarm Data CRC is incorrect." ::= 12 trapDM870FactoryDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Factory Data CRC is incorrect." ::= 13 trapDM870CalDataCRCAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Cal Data CRC is incorrect." ::= 14 trapDM870ResetFacDefault TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the DM870 resets to factory defaults" ::= 15 trapDM870UserRFOffAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the the User RF is turned off." ::= 16 trapDM870UserOpticalOffAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User Optical Power is turned off." ::= 17 trapDM870UserSBSOffAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the User SBS is turned off." ::= 18 trapDM870RFInputAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 19 trapDM870RFOverloadAlarm TRAP-TYPE ENTERPRISE gx2Dm870 VARIABLES { trapIdentifier, trapNetworkElemModelNumber, trapNetworkElemSerialNum, trapPerceivedSeverity, trapNetworkElemOperState, trapNetworkElemAlarmStatus, trapNetworkElemAdminState, trapNetworkElemAvailStatus, trapText, trapChangedObjectId, trapChangedValueInteger, trapNETrapLastTrapTimeStamp } DESCRIPTION "This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter." ::= 20 END -- // Section: Header & History