Nortel-MsCarrier-MscPassport-AtmEbrMIB :: mscAtmIfVccSrcEbrOvRecoverySubscribed

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-AtmEbrMIB › mscAtmIfVccSrcEbrOvRecoverySubscribed

mscAtmIfVccSrcEbrOvRecoverySubscribed

Module: Nortel-MsCarrier-MscPassport-AtmEbrMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-AtmEbrMIB::mscAtmIfVccSrcEbrOvRecoverySubscribed

OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attributes specifies whether connection recovery is subscribed for this connection.

What is mscAtmIfVccSrcEbrOvRecoverySubscribed?

Whether connection recovery (hard rerouting after a failure) is subscribed for a provisioned SPVC (permanent virtual channel) connection, overriding the interface's default subscription; defaults to yes. An admin sets this to no on a connection that should stay down rather than reroute, for example a test circuit that must not silently move.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmEbrMIB::mscAtmIfVccSrcEbrOvRecoverySubscribed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmEbrMIB::mscAtmIfVccSrcEbrOvRecoverySubscribed.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1.1.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> mscAtmIfVccSrcEbrOvRecoverySubscribed.1

Start monitoring Nortel MsCarrier MscPassport ATM switch (Enhanced Bit Rate bandwidth management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmEbrMIB::mscAtmIfVccSrcEbrOvRecoverySubscribed OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport ATM switch (Enhanced Bit Rate bandwidth management) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.114mscAtmIfNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5mscAtmIfVccNortel-MsCarrier-MscPassport-AtmCoreMIB
1.3.6.1.4.1.562.36.2.1.114.5.8mscAtmIfVccSrcNortel-MsCarrier-MscPassport-AtmNetworkingMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.114.5.8.2mscAtmIfVccSrcEbrOvNortel-MsCarrier-MscPassport-AtmEbrMIB
1.3.6.1.4.1.562.36.2.1.114.5.8.2.20mscAtmIfVccSrcEbrOvProvTableNortel-MsCarrier-MscPassport-AtmEbrMIB
1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1mscAtmIfVccSrcEbrOvProvEntryNortel-MsCarrier-MscPassport-AtmEbrMIB
1.3.6.1.4.1.562.36.2.1.114.5.8.2.20.1.1mscAtmIfVccSrcEbrOvRecoverySubscribedNortel-MsCarrier-MscPassport-AtmEbrMIB