| OID symbolic | OID numeric | Type | Access | Description |
| STR nscHippiSonetEngineStatus | 1.3.6.1.4.1.10.2.1.5.1 | DisplayString | read-only | String describing the current state of the engine. |
| nscHippiSonetRegisters | 1.3.6.1.4.1.10.2.1.5.2 | | | |
| nscHippiSonetUnframer | 1.3.6.1.4.1.10.2.1.5.2.1 | | | |
| STR nscHippiSonetUnframerStatus | 1.3.6.1.4.1.10.2.1.5.2.1.1 | DisplayString | read-only | Unframer status register. |
| STR nscHippiSonetUnframerOHdma | 1.3.6.1.4.1.10.2.1.5.2.1.2 | DisplayString | read-only | Unframer overhead DMA register. |
| nscHippiSonetFramer | 1.3.6.1.4.1.10.2.1.5.2.2 | | | |
| STR nscHippiSonetFramerStatus | 1.3.6.1.4.1.10.2.1.5.2.2.1 | DisplayString | read-only | Framer status register. |
| STR nscHippiSonetFramerAdaptID | 1.3.6.1.4.1.10.2.1.5.2.2.2 | DisplayString | read-only | Adaptor ID (HDA) and enable status. |
| STR nscHippiSonetFramerInput | 1.3.6.1.4.1.10.2.1.5.2.2.3 | DisplayString | read-only | Framer input register. |
| STR nscHippiSonetFramerData | 1.3.6.1.4.1.10.2.1.5.2.2.4 | DisplayString | read-only | Framer data register. |
| STR nscHippiSonetFramerIField | 1.3.6.1.4.1.10.2.1.5.2.2.5 | DisplayString | read-only | Framer I-Field register. |
| nscHippiSonetMegaFifo | 1.3.6.1.4.1.10.2.1.5.2.3 | | | |
| STR nscHippiSonetMFcontrol | 1.3.6.1.4.1.10.2.1.5.2.3.1 | DisplayString | read-only | Mega FIFO control register. |
| STR nscHippiSonetMFstatus | 1.3.6.1.4.1.10.2.1.5.2.3.2 | DisplayString | read-only | Mega FIFO status register. |
| STR nscHippiSonetMFtimeout | 1.3.6.1.4.1.10.2.1.5.2.3.3 | DisplayString | read-only | Mega FIFO timeout register. |
| STR nscHippiSonetMFConnectStatus | 1.3.6.1.4.1.10.2.1.5.2.3.4 | DisplayString | read-only | Mega FIFO connection status register. |
| nscHippiSonetMonitor | 1.3.6.1.4.1.10.2.1.5.3 | | | |
| INT nscHippiSonetMonClock | 1.3.6.1.4.1.10.2.1.5.3.1 | INTEGER | read-only | 500 Khz clock value (for time stamps). |
| INT nscHippiSonetMonMFFlowControl | 1.3.6.1.4.1.10.2.1.5.3.2 | INTEGER | read-only | Mega FIFO flow control duration. |
| INT nscHippiSonetMonDLFlowControl | 1.3.6.1.4.1.10.2.1.5.3.3 | INTEGER | read-only | Down line flow control duration |
| INT nscHippiSonetMonBIPErrors | 1.3.6.1.4.1.10.2.1.5.3.4 | INTEGER | read-only | Received path BIP Errors. |
| INT nscHippiSonetMonSrcBusy | 1.3.6.1.4.1.10.2.1.5.3.5 | INTEGER | read-only | Duration in 500Khz that the source was busy. |
| INT nscHippiSonetMonSrcSOC | 1.3.6.1.4.1.10.2.1.5.3.6 | INTEGER | read-only | Number of source start of connections |
| INT nscHippiSonetMonSrcEOC | 1.3.6.1.4.1.10.2.1.5.3.7 | INTEGER | read-only | Number of source end of connections |
| INT nscHippiSonetMonDstConnectDuration | 1.3.6.1.4.1.10.2.1.5.3.8 | INTEGER | read-only | Number 500Khz cycles destination has been connected |
| INT nscHippiSonetMonSrcConnectDuration | 1.3.6.1.4.1.10.2.1.5.3.9 | INTEGER | read-only | Number 500Khz cycles source has been connected |
| INT nscHippiSonetMonDstConnectReject | 1.3.6.1.4.1.10.2.1.5.3.10 | INTEGER | read-only | Number of Destination connect rejects. |
| INT nscHippiSonetMonSrcConnectFail | 1.3.6.1.4.1.10.2.1.5.3.11 | INTEGER | read-only | Number of source connect failures. |
| INT nscHippiSonetMonLOF | 1.3.6.1.4.1.10.2.1.5.3.12 | INTEGER | read-only | Number of receive sonet Loss of Frame events |
| INT nscHippiSonetMonLOS | 1.3.6.1.4.1.10.2.1.5.3.13 | INTEGER | read-only | Number of receive sonet Loss of Signal events |
| INT nscHippiSonetMonDstBursts | 1.3.6.1.4.1.10.2.1.5.3.14 | INTEGER | read-only | Number of Destination bursts |
| INT nscHippiSonetMonDstPackets | 1.3.6.1.4.1.10.2.1.5.3.15 | INTEGER | read-only | Number of Destination packets |
| INT nscHippiSonetMonDstSync | 1.3.6.1.4.1.10.2.1.5.3.16 | INTEGER | read-only | Number of Destination sync errors |
| INT nscHippiSonetMonDstLLRC | 1.3.6.1.4.1.10.2.1.5.3.17 | INTEGER | read-only | Number of Destination LLRC errors |
| INT nscHippiSonetMonDstPE | 1.3.6.1.4.1.10.2.1.5.3.18 | INTEGER | read-only | Number of Destination Parity Errors |
| INT nscHippiSonetMonDstConnect | 1.3.6.1.4.1.10.2.1.5.3.19 | INTEGER | read-only | Number of Destination connects |
| INT nscHippiSonetMonSrcConnect | 1.3.6.1.4.1.10.2.1.5.3.20 | INTEGER | read-only | Number of source connects |
| INT nscHippiSonetMonSrcPackets | 1.3.6.1.4.1.10.2.1.5.3.21 | INTEGER | read-only | Number of source packets |
| INT nscHippiSonetMonSrcBursts | 1.3.6.1.4.1.10.2.1.5.3.22 | INTEGER | read-only | Number of source bursts |
| INT nscHippiSonetMonSrcForceErrors | 1.3.6.1.4.1.10.2.1.5.3.23 | INTEGER | read-only | Number of Source Bad-data Force Errors |
| INT nscHippiSonetMonSrcCRC | 1.3.6.1.4.1.10.2.1.5.3.24 | INTEGER | read-only | Number of Source CRC errors |
| INT nscHippiSonetMonDstWords | 1.3.6.1.4.1.10.2.1.5.3.25 | INTEGER | read-only | Number of Destination burst words / 32 (Kbits) |
| INT nscHippiSonetMonSrcWords | 1.3.6.1.4.1.10.2.1.5.3.26 | INTEGER | read-only | Number of Destination burst words / 32 (Kbits) |
| nscHippiSonetAtoD | 1.3.6.1.4.1.10.2.1.5.4 | | | |
| INT nscHippiSonetADRecvOpticalPower | 1.3.6.1.4.1.10.2.1.5.4.1 | INTEGER | read-only | Receive optical power in dbm's |
| INT nscHippiSonetADLaserBias | 1.3.6.1.4.1.10.2.1.5.4.2 | INTEGER | read-only | Laser bias voltage (in milli-volts) |
| INT nscHippiSonetADLaserBackface | 1.3.6.1.4.1.10.2.1.5.4.3 | INTEGER | read-only | Laser backface voltage (in milli-volts) |
| INT nscHippiSonetADInternalTemp | 1.3.6.1.4.1.10.2.1.5.4.4 | INTEGER | read-only | Internal temperature (degrees F) |
| INT nscHippiSonetADExhaustTemp | 1.3.6.1.4.1.10.2.1.5.4.5 | INTEGER | read-only | Exhaust temperature (degrees F) |
| STR nscHippiSonetSourceIField | 1.3.6.1.4.1.10.2.1.5.5 | DisplayString | read-only | Hippi source I-Field register. |
| nscHippiSonetProfile | 1.3.6.1.4.1.10.2.1.5.6 | | | |
| STR nscHippiSonetOpticalRcvOffset | 1.3.6.1.4.1.10.2.1.5.6.1 | DisplayString | read-only | String representation of the floating value for
the offset of the optical receive light formula. |
| STR nscHippiSonetOpticalRcvSlope | 1.3.6.1.4.1.10.2.1.5.6.2 | DisplayString | read-only | String representation of the floating value for
the slope of the optical receive light formula. |
| INT nscHippiSonetBiasCurrent | 1.3.6.1.4.1.10.2.1.5.6.3 | INTEGER | read-only | Integer representation of the floating value for
the baseline current of the transmit laser in
milliamps. This value is used by the machine to
determine the life of the laser. |
| INT nscHippiSonetBiasTemp | 1.3.6.1.4.1.10.2.1.5.6.4 | INTEGER | read-only | Temperature in celcius at which the profiled
bias current was taken. This value is used with
the bias current to determine the life of the laser. |
| STR nscHippiSonetBackfaceVoltage | 1.3.6.1.4.1.10.2.1.5.6.5 | DisplayString | read-only | String representation of the floting value of the
Voltage in millivolts that was measured at the
backface of the laser when it was new. This value
is used with the current backface voltage as an
additional method of determining if the transmit
laser has become defective. |
| INT nscHippiSonetIField | 1.3.6.1.4.1.10.2.1.5.6.6 | INTEGER | read-write | The I-Field address that is used by the hippi
interface. |
| INT nscHippiSonetBootPort | 1.3.6.1.4.1.10.2.1.5.6.7 | INTEGER | read-write | Which rs232 port the boot information should be sent
to. Ports 1 & 2 are the only valid ports with 1 being
located on the back of the machine and 2 on the front. |
| INT nscHippiSonetPortSpeed | 1.3.6.1.4.1.10.2.1.5.6.8 | INTEGER | read-write | The baud rate to set the rs232 ports to at boot time. |
| INT nscHippiSonetThreshold | 1.3.6.1.4.1.10.2.1.5.6.9 | INTEGER | read-write | Threshold of the mega-fifo at which flow control will
be activated. The value represents 8ths of the fifo
with 7 representing the fifo must be full before flow
control is activated and 0 indicating that flow control
will happen as soon as the mega-fifo starts to fill.
This value may need to be adjusted to deal with time
delays over vary long sonet links in that you want flow
control to propagate back to the transmitting sonet box
before it puts enough information on the line to
overflow this machine. |
| INT nscHippiTimeout | 1.3.6.1.4.1.10.2.1.5.6.10 | INTEGER | read-write | Timeout value to use when trying to connect from our
hippi source. This timer is started when the source
raises connect. If the destination fails to respond
before the timer goes off, the connect will be aborted.
The timer is represented as the number of 500 KHz
clock ticks. |
| INT nscHippiSonetDipSwitch | 1.3.6.1.4.1.10.2.1.5.6.11 | INTEGER | read-write | This is a software switch that functions much like
a hardware dip switch. At the moment, the only use
of this switch is to define whether the unit will
act as the master clock for the sonet line. The
bit values are defined as follows:
x x x x x x 1 - assert master clock
x x x x x 1 x - not assigned
x x x x 1 x x - not assigned
x x x 1 x x x - not assigned
x x 1 x x x x - not assigned
x 1 x x x x x - not assigned
1 x x x x x x - not assigned |